Manual de usuario Heat & Glo LifeStyle, modelo 6000G-IPILP

Fabricar: Heat & Glo LifeStyle
Tamaño del archivo: 3.6 mb
Nombre del archivo: 6000g_install.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


• Lubricate pipe or flue with water and slide the flashing down. It may be necessary to trim the top shingles around the base of the rubber boot to ensure a good fit. • Draw around fl ashing, remove. • Apply silicone sealant to roof inside the lines (Figure 8.20). • Lubricate pipe or flue with water and slide fl ashing down. Seat firmly in sealant. Nail roof flashing to the roof. • Apply silicone sealant on the top outside of the base plate Figure 8.20 Apply Sealant APPLY SEALANT TOP & PARTIAL SIDES Figure 8.21 Slide Flashing Down, Secure & Apply Sealant on the sides and on top edge. See Figure 8.21. Install shingles, Apply sealant at the top edge of the rubber boot. See Figure 8.22. • We recommend that you top coat with conventional acrylic house paint to improve the appearance of your galvanized base flashing. SHINGLES TRIMMED SHINGLES OVER FLASHING FLASHING OVER SHINGLES SILICONE SEALANT (TOP OF BOOT) Figure 8.22 Installation Complete Figure 8.19 Trim Rubber Boot Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 J. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar of the cap over the outer flue of the pipe section. • Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer flue of the pipe (see Figure 8.23). SCREWS CAULK STORM COLLAR (1 of 3) Figure 8.23Figure 8.23 TERMINATION CAP K. Install Decorative Wall Components (SLP only) A decorative wall thimble can be installed on wall through which the vent passes. The decorative wall thimble is used to cover the wall shield firestop. • Slide the decorative wall thimble over the last section of horizontal pipe before connecting the termination cap to the pipe. • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 8.24. L. Heat Shield Requirements for Horizontal Termination WARNING! Risk of Fire! To prevent overheating and fire, heat shields must extend through the entire wall thickness. • DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap (shown in Figure 10.25). • Heat shields must overlap 1-1/2 in. (38 mm) minimum. There are two sections of the heat shield. One section is factory-attached to the wall shield fi restop. The other section is factory-attached to the cap. See Figure 10.25. If the wall thickness does not allow the required 1-1/2 in. (38 mm) heat shield overlap when installed, an extended heat shield must be used. • If the wall thickness is less than 4 in./102 mm (DVP) or 4-3/8 in./ 111 mm (SLP), the heat shields on the cap and wall shield firestop must to be trimmed. A minimum 1-1/2 in. (38 mm) overlap MUST be maintained. • Use an extended heat shield if the finished wall thickness is greater than 7-1/4 in. (184 mm). • The extended heat shield may need to be cut to length maintaining sufficient length for a 1-1/2 in. (38 mm) overlap between heat shields. • Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to vent components diagrams in the back of this manual. • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Figure 8.24 Wall Thimble Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08 35 Figure 8.25 Venting through the wall INTERIOR HEAT SHIELD OR EXTENDED HEAT SHIELD WALL SHIELD FIRESTOP HEAT SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEATHING VENT DEPTH FROM BACK OF APPLIANCE TO OUTSIDE SURFACE OF EXTERIOR WALL (SEE CHART BELOW) SLIP SECTION CAN BE EXTENDED INNER VENT OUTER VENT EXTERIOR Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield fi restop is required on the exterior side of a combustible wall. M. Install Horizontal Termination Cap (DVP and SLP Pipe) WARNING! Risk of Fire! The telescoping fl ue section of the termination cap MUST be used when connecting vent. • 1-1/2 (38 mm) minimum overlap of fl ue telescoping section is required. Failure to maintain overlap may cause overheating and fi re. • Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base. • Flash and seal as appropriate for siding material at outside edges of cap. • When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149 installation codes and refer to Section 6 of this manual. CAUTION! Risk of Burns! Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap. NOTICE: For certain exposures which require superior resist...

Otros modelos de este manual:
Los acondicionadores de aire - 6000G (3.6 mb)
Los acondicionadores de aire - 6000G-IPI (3.6 mb)
Los acondicionadores de aire - 6000G-LP (3.6 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría