sensor disconnected 0 0 0 14-TSF short on condenser sensor 0 0 o ................ 15-TSF condenser sensor 0 0 0 0 The end of the self-test will be signalled by all the leds lighting up at once and blinking ten times, as well as by an acoustic signal. At this time, you can adjust the temperature reading on the room temperature sensor. This correction is important if the air conditioner is installed high on the wall in a room where the warm air tends to stratify upward (as in rooms with high ceilings or other sources of heat besides the air conditioner). The sensor will read a temperature 3°C lower than the effective one, in this case, to compensate for the difference between the lower inhabited part of the room and the temperature at the height of the sensor. To enter or remove this correction proceed as follows: 1 Check the status of the machine as described previously, and if no correction has been made, press the button on the console while the acoustic signal is on at the end of the self-test, 2 To remove the correction, press the button while the acoustic signal is on at the end of the self-test. digitemp 15 Xpelair 2.5.1 Evacuation of condensation water in case of emergency CHAP. 2.6 The machine is set in the factory without correction of the temperature. In addition to the self-test (that can be made under any conditions of room temperature) we recommend that you also test the product in the various operating modes accessible to the user (see the user manual). One important test you should make concerns regular evacuation of condensation water on the models with heat pump. To check this, keep the machine running for at least 4-5 hours in the heating mode. If the water does not drain, there should be an “overflow” alarm. If there should be a malfunction in the condensation water drain system, the air conditioner stops working and signals, with flashing orange, green and red lights (the second and third leds from the left), the alarm status. To enable the air conditioner to work temporarily until the service personnel arrives, you can drain the water out by following these simple instructions: - Grasp the rubber cap on the bottom centre of the air conditioner behind the edge of the frame facing the wall between your thumb and forefinger. - Pull the rubber tube closed by the cap out by a few centimetres. - Remove the cap after placing a bucket or other container underneath it (at least five litre capacity) to collect the water (see fig. 23). - After eliminating the malfunction the service personnel will take care of closing the evacuation tube. PERIODICAL MAINTENANCE Air conditioners of this type do not require any particular routine maintenance except: - Cleaning or washing the room air filter when the red light comes on (see user manual). - Cleaning of air inlet radiator, to be done as needed, depending on the amount of dirt in the external air, once or twice a year. To do this, you must isolate the unit and then remove the front casing and the noise insulation on the inside. - Cleaning can be done using a vacuum cleaner or soft brush, taking particular care not to damage the aluminium heat exchanger baffles. It may be necessary to use a damp cloth and detergents to remove heavily encrusted dirt. Note: after cleaning the radiator replace the noise insulation carefully matching the edges and gaskets with their reference markings. Before you leave the site of installation you should gather up all packing material and use a damp cloth to remove any traces of dust that may have deposited on the machine during assembly (fig. 24). To prevent unnecessary calls by the user, before you leave the site of installation it is also a good idea to: - Explain the contents of the I nstruction Manual to the user. - Show him how to clean the filter. - Explain when and how he should contact the Service Department Fig. 24 16 digitemp !A OP CHAP. 3 USE AND MAINTENANCE (for the user) CHAP. 3.1 Important Recommendations Installation and connection of the air conditioner should be carried out by a qualified or competent person. The instructions for installation are provided in the specific manual. No structural object (furniture, curtains, plants, leaves, blinds, etc.) should ever obstruct the normal flow of air from either the internal or external grille. Never lean or, worse yet, sit on the casing of the air conditioner as this could cause serious damage to the external parts. Do not turn the horizontal airflow baffles by hand. Always use the remote control to adjust baffle position. If the unit leaks water, switch it off immediately and disconnect it from the power mains. Call the XPELAIR TECHNICAL SERVICE : Technical Phone № 08709 000430 Technical Fax № 08709 000530 When the air conditioner is heating, it has to periodically eliminate any ice that could form on the air outlet radiator. While it is doing this, the machine keeps running but does not heat the room. This last...

Otros modelos de este manual:
Los acondicionadores de aire - 91154AA (2.68 mb)
Los acondicionadores de aire - 91173AA (2.68 mb)
Los acondicionadores de aire - 91175AA (2.68 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría