|
Resumen del manual
• When vertical airflow direction is set to AUTO, it stops at lower position to avoid cold air contact. However, you can adjust the louver direction manually. Multi Split System • Function not applicable. 9 TO SWITCH BETWEEN POWERFUL & QUIET POWERFUL/ QUIET QUIETPOWERFUL NORMAL POWERFUL TO REACH TEMPERATURE QUICKLY POWERFUL • Single Split System: This operation stops automatically after 20 minutes. • Multi Split System: Press the button again or turn OFF the unit to stop this operation. QUIET TO ENJOY QUIET OPERATION QUIET • This operation reduces airfl ow noises. 10 11 TO MONITOR HUMAN PRESENCE & ACTIVITY FOR ENERGY SAVING & COMFORT ECONAVI To optimize energy saving ECONAVI AUTO COMFORT To maximize comfort AUTO COMFORT Set Fan Speed -2°C -1°C HEAT Mode Set Temperature +0.3°C Heat Source & Movement NormalHighLowNoneSet Fan Speed . Medium Fan +1 tap* +2°C -1°C +1 tap +0.3°CCOOL/DRY ModeSet Temperature * For first 15 minutes or until set temperature is reached. • The human activity sensor may not detect moving objects further than 7m away or beyond detection angle. • The human activity sensor sensitivity is infl uenced by indoor unit location, movement speed, temperature range, etc. • The human activity sensor may: -Mistakenly detects an object with heat source & movement similar to human, such as pets, etc. ashuman being. -Mistakenly detects as non-heat source & movement ifa person stays motionless for certain period of time. ENGLISH5 TO ADJUST VERTICAL AIRFLOW DIRECTION (5 OPTIONS) AIR SWING • Keeps the room ventilated. • In COOL/DRY mode, if AUTO is set, the louver swing up/down automatically. • In HEAT mode, if AUTO is set, the louver fi x at predetermined position. 6 TO ADJUST VERTICAL AIRFLOW DIRECTION (5 OPTIONS) AIR SWING • Keeps the room ventilated. • In COOL/DRY mode, if AUTO is set, the louver swing left/right and up/down automatically. • In HEAT mode, if AUTO is set, the horizontal louver fi x at predetermined position. The vertical louver swing left/right after the temperature rises. 7 TO PURIFY THE AIR NANOE-G • Removes/deactivates harmful micro-organisms such as viruses, bacteria, etc. • Can be activated even when the unit is turned off. In this condition, fan speed and air swing cannot be adjusted. • nanoe-G starts automatically with the unit switched on with OFF/ON . 8 TO IMPROVE HUMIDITY AND MOISTURE LEVEL Single Split System • This operation reduces air dryness and provides you with a comfortable living environment during COOL mode only. • When vertical airflow direction is set to AUTO, it stops at lower position to avoid cold air contact. However, you can adjust the louver direction manually. Multi Split System • Function not applicable. 9 TO SWITCH BETWEEN POWERFUL & QUIET POWERFUL/ QUIET QUIETPOWERFUL NORMAL POWERFUL TO REACH TEMPERATURE QUICKLY POWERFUL • Single Split System: This operation stops automatically after 20 minutes. • Multi Split System: Press the button again or turn OFF the unit to stop this operation. QUIET TO ENJOY QUIET OPERATION QUIET • This operation reduces airfl ow noises. 10 11 TO MONITOR HUMAN PRESENCE & ACTIVITY FOR ENERGY SAVING & COMFORT ECONAVI To optimize energy saving ECONAVI AUTO COMFORT To maximize comfort AUTO COMFORT Set Fan Speed -2°C -1°C HEAT Mode Set Temperature +0.3°C Heat Source & Movement NormalHighLowNoneSet Fan Speed . Medium Fan +1 tap* +2°C -1°C +1 tap +0.3°CCOOL/DRY ModeSet Temperature * For first 15 minutes or until set temperature is reached. • The human activity sensor may not detect moving objects further than 7m away or beyond detection angle. • The human activity sensor sensitivity is infl uenced by indoor unit location, movement speed, temperature range, etc. • The human activity sensor may: -Mistakenly detects an object with heat source & movement similar to human, such as pets, etc. ashuman being. -Mistakenly detects as non-heat source & movement ifa person stays motionless for certain period of time. 8 TIMER SET CANCEL ON OFF 1 2 3 SET CHECK CLOCK RESET AC RC REMOTE CONTROL TO SET THE TIMERTO SET THE TIMER • 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time. • Complete below procedures to set each timer: ON OFF 1 Cancel Cancel 2 TIMER SET Select ON or OFF timer Set the time Confirm • Example of application at living room: Morning: ON at 07:00 (Wake up) OFF at 08:00 (Out for work) Evening: ON at 17:00 (Back home) OFF at 22:00 (Sleep) • To cancel ON or OFF timer, press ON or OFF to select respective or then press CANCEL. • If timer is cancelled manually or due to power failure, you can restore the timer again by pressing ON or OFF to select respective or then press SET . • Upcoming timer will be displayed and will be activated in sequence. • When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time. • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock se...
Otros modelos de este manual:Los acondicionadores de aire - CS-E7 (4.3 mb)
Los acondicionadores de aire - CS-E9 (4.3 mb)
Los acondicionadores de aire - CS-E15 (4.3 mb)
Los acondicionadores de aire - CS-E18NKDW (4.3 mb)