Iniciar sesión:
Votos - 1, Puntuación media: 3 ( )

Manual de usuario DeLonghi, modelo PINGUINO PACT100P

Fabricar: DeLonghi
Tamaño del archivo: 823.28 kb
Nombre del archivo: b306d90f-636d-47ea-a6ae-f1e089fa4ee4.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


With the “BOOST” function activated, the display on the control panel shows . SMART FUNCTION In “SMART” function, the air-conditioning unit decides the best way to operate to guarantee maximum comfort. •Press the button (I) to turn the appliance on. The symbol flashes on the display and a “beep” indicates that the air- conditioning unit is on. •Press the SMART button (G). The appliance functions automati75 F 60%RH Remote control functions Remote control functions cally and the symbol appears on the display. Note: in “SMART” function, the temperature is controlled automatically. However, if the required temperature has not yet been reached, it can be reduced or increased by a maximum of 4°F (approx. 2°C) by pressing the buttons. The appliance automatically establishes the operating mode (airconditioning, fan, heating) and the optimum fan speed. With the “SMART” function activated the display on the control panel shows and the three indicator lights (C/D/E) will come on. SLEEP FUNCTION The automatic “SLEEP” function is ideal for the night-time as it enables operation of the air-conditioning unit in the air-conditioning mode to be gradually reduced until it shuts down completely (after eight hours). To select “SLEEP” function, proceed as follows: •Press the button (I) to turn the appliance on. • The symbol flashes on the display and a “beep” indicates that the air-conditioning unit is on. •Press the MODE button (A) a number of times until the symbol of the function required appears on the display. •Then select the required temperature by pressing the • Now press the SLEEP button (F) to set the night function. The symbol is displayed. With the “SLEEP” function activated, the fan operates at low speed. On the control panel the indicator light (F) comes on. Press the SLEEP button again to go back to the previous mode. Note: The SLEEP function maintains the room temperature at the optimum level, avoiding excessive increases or drops in the temperature, with silent operation. The flow of air decreases, while the room temperature varies gradually according to the comfort requirements: increases of approx. 2°F (approx.1°C) after 60 minutes and approx. 4°F (approx.2°C) after 2 hours (it switches off altogether after eight hours). PROGRAMMING THE TIMER The timer can be used to delay appliance start up or shut down. This avoids wasting electricity by optimizing operating periods. Programming shut-down •With the air-conditioning unit on, press the TIMER button (E). The time is displayed and the “h” symbol flashes. Set the time when you want the appliance to go off using the buttons (from 30 minutes to 24 hours). During the first ten hours, you can select half hour intervals. For times greater than ten hours, one hour intervals can be selected. •Press the TIMER button again to confirm the selection. A countdown of the time left is displayed. • At the end of the set time the appliance switches off automatically. •To cancel the set time, press the TIMER button again. You will hear a “beep”. Programming start-up •With the air-conditioning unit off, press the TIMER button (E). The time is displayed and the “h” symbol flashes. Set the time when you want the appliance to come on using the buttons (from 30 minutes to 24 hours). During the first ten hours, you can select half hour intervals. For times greater than ten hours, one hour intervals can be selected. •Press the TIMER button again to confirm the selection. • At the end of the set time the appliance switches on automatically. •To cancel the set time, press the TIMER button again. You will hear a “beep”. buttons. 79 F 18 Self diagnosis/Troubleshooting Self diagnosis/Troubleshooting SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions. IF THE DISPLAY SHOWS … …WHAT SHOULD YOU DO? LOW TEMPERATURE (frost prevention) When appears on the display, the ice prevention device has been triggered. The appliance starts up again automatically when the defrosting process is completed. p pp f ff PROBE FAILURE (sensor damaged) If this is displayed, an authorized De'Longhi service center. FULL TANK Empty the tank on the back of the appliance and replace it correctly. The continuous drain hose is not connected correctly or is obstructed and the air conditioner is draining into the tank. F FF I II FAILURE 1 If this is displayed, contact an authorized De'Longhi service center. TROUBLESHOOTING PROBLEM CAUSE REMEDY The air conditioning • no electricity •restore electricity unit does not start • it is not plugged into the socket • plug into the socket • the safety device has tripped •reset the safety plug ( see pag. 18) The air conditioning • the air exhaust hose or the intake hose has a • position the exhaust hose or unit works for a constriction the intake hose correctly short time only • the air exhaust hose or the intake hose is • check there are no obstacles blocked obstructing air discharge or the intake hose • there are tight bends in the air exhaus...

Otros modelos de este manual:
Los acondicionadores de aire - PINGUINO PACT110P (823.28 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría