Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Haier, modelo 0010515222

Fabricar: Haier
Tamaño del archivo: 2.04 mb
Nombre del archivo: 090ef3db-cd73-495a-8a9c-0dea95623e7d.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fireplaceor other heating apparatus. Check good condition of the installation stand Do not pour water onto the unitfor cleaning PROHIBITION Do not place animals or plants inthe direct path of the air flow Do not place any objects on orclimb on the unit. Do not place flower vase or watercontainers on the top of the unit. PROHIBITION CAUTION 4 Parts and Functions Indoor unit Outlet Inlet Inlet grille Anion generator(inside) Vertical blade(inside) (adjust left and right air flow) air ionization purify layer(inside) Air filter(inside) Vitamin C layer+ Bacteria-killing medium sets(inside) display board(inside) Horizontal flap (adjust up and down air flow Don't adjust it manually) Power plug Outdoor unit 12 OUTLET 34 CONNECTING PIPING AND ELECTRICALWIRING INLET DRAIN HOSE 5 Parts and Functions 33 34 16 21 1711 15 22 Used for unit start and stop. 10. ON/OFF button 11. TIMER ON display 12. FAN SPEED display LOW HIMED AUTO 13. LOCK display 14. SWING UP/DOWN display 15. SLEEP display 16. HEALTH display Operation mode AUTO FAN COOL DRY Remote controller 17. Operation mode display Display board 19. POWER/SOFT display 20. Left/right air flow display Remote controller: to display the TEMP. setting. 21. TEMP display 18.Singal sending display POWER/SOFT FRESH PURIFY Parts and Functions 33 34 16 21 1711 15 22 Used for unit start and stop. 10. ON/OFF button 11. TIMER ON display 12. FAN SPEED display LOW HIMED AUTO 13. LOCK display 14. SWING UP/DOWN display 15. SLEEP display 16. HEALTH display Operation mode AUTO FAN COOL DRY Remote controller 17. Operation mode display Display board 19. POWER/SOFT display 20. Left/right air flow display Remote controller: to display the TEMP. setting. 21. TEMP display 18.Singal sending display POWER/SOFT FRESH PURIFY 19 28 22. TIMER OFF display 23. CLOCK display 1.CODE 24. TEMP button Used to select CODE A or B with a press,A or B Used to select your desired temperature. will be displayed on LCD. 25. FAN button Please select A without special explanation. Used to select fan speed: LOW,MED, HI, AUTO. 2.RESET 26. HEALTH AIRFLOW button When the remote controller appears abnormal, Used to set the health airflow mode. use a sharp pointed article to press this button to reset the remote controller normal. 27. SWING UP/DOWN button Used to select up or down air sending direction. 3.LIGHT button 28. SWING LEFT/RIGHT button Control the lightening and extinguishing of Used to select left/right air flow. the indoor LED display board. 29. FRESH button(optional) 4. TIMER button Use to set fresh air function. Used to select TIMER ON, TIMER OFF, 30. SET button TIMER ON-OFF. Used to confirm timer and clock settings. 5. CLOCK button 31. POWER/SOFT button Used to set correct time. Used to set power/soft function. 6. SLEEP button 32. LOCK Used to select sleep mode. Used to lock buttons and LCD display. If pressed, the 7. MODE button other buttons will be disabled and the lock condition display appears. Press it once again, lock will be AUTO COOL DRY FAN canceled and lock condition display disappears. 8. HOUR button 33. Remote signal receiverUsed to set clock and timer setting. 34. Emergency operation button(touch key) 9. Purify button Used to set emergency operation and test operation. Used to set air ionization purify and healthy function. NOTE: 1.Cooling only unit do not have functions and displays related with heating. 2.The CODE button on this remote controller is not available. 6 Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key. Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Remote controller's operation 3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working. 2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly. 1. Press CLOCK button,"AM" or "PM" flashes. When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw or knock the remoter controller. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter. Loading of the battery Load the batteries as illustrated right 2 R-03 (7#) batteries Remove the battery cover: Slightly press" "area and push down the cover as illustrated. Load the battery: Be sure that the loading is in line with the "+" / "-". request as illustrated on the bottom of the case. Put on the cover again. Confirmation indicator: After pressing...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría