Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Sub-Zero, modelo CTWH36

Fabricar: Sub-Zero
Tamaño del archivo: 207.27 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


It is NOT recommended for use with Wolf dual fuel ranges, gas ranges and range- tops. Any violation of this application may void your warranty for one or both products. WOLF WARRANTY Wolf products are covered by a two and five year residential warranty (exclusions apply). See warranty details at the end of this guide. controls Seamless construction Telescopic chimney flue extension Front mounted Halogen lighting LED indicators Dimensions in parentheses are in millimeters unless otherwise specified. WOLF COOKTOP VENTILATION HOOD USE & CARE VENTILATION HOOD CONTROLS The ventilation hood is operated using the controls along the front edge of the hood. The LIGHT button turns the halogen lights on and off. The LIGHT button also allows you to brighten or dim lighting. Lighting has three levels, high, medium and low. The blower operates at three speeds. The HIGH, MEDIUM or LOW button can be pressed to activate the blower. The corresponding LED indicator will illuminate to indicate the blower speed. To turn the ventilation hood off, depress the speed control a second time. For example, if you have the blower running at low speed, press the LOW button to turn off the blower. The LED next to the FILTER button on the controls will illuminate when it is time to clean the filters. This indicator light comes on after approximately 30 hours of operation. Refer to Filter Care on page 11. To reset the FILTER clean LED indicator, press the FILTER button. DELAY-OFF MODE The delay-off mode will allow the ventilation hood blower to continue operating at the selected speed for approximately five minutes after the DELAY button has been pressed. This mode allows you to leave the cooking area, while the ventilation hood is still in operation; it will then shut off. In delay-off mode, both the DELAY LED and the corresponding blower speed LED will be illuminated. If the blower is on high speed and the DELAY button is pressed, the blower will stay on high speed for five minutes. It will then switch to low speed for an additional five minutes before turning off. If the blower is on medium speed and the DELAY button is pressed, the blower will stay on medium speed for five minutes. It will then switch to low speed for an additional five minutes before turning off. If the blower is on low speed and the DELAY button is pressed, the blower will stay on low speed for five minutes before turning off. If the DELAY button is pressed when the blower is off, no operation will take place. If the DELAY button is pressed when the unit is already in delay-off mode, the delay- off mode will be cancelled. Three-speed Light button blower controls Filter clean LED indicator Delay-off button Ventilation hood controls WOLF COOKTOP VENTILATION HOOD USE & CARE HEAT SENTRY FEATURE The heat sentry feature will help you maintain your cooking environment and allows your ventilation hood to sense when blower operation is needed. The heat sentry feature is always in wait and is activated when the exhaust temperature from the hood reaches 206°F (97°C). At this temperature, the blower motor speed will automatically adjust to the next highest speed. For example, if the blower motor is in low speed and the threshold temperature is reached, the blower will increase to medium speed. The corresponding LED on the control will blink to indicate the heat sentry feature blower speed. Once heat sentry feature is activated, the ventilation hood will continue to monitor exhaust temperatures every three minutes. If the exhaust temperature reaches 206°F (97°C), the blower speed will increase to the next highest speed and the corresponding LED will blink. If after three minutes the exhaust temperature falls below 174°F (79°C), the blower speed will decrease to the next lowest speed. If the blower was off prior to heat sentry feature activation, the unit will turn off when exiting the heat sentry feature. When the blower speed returns to the original setting prior to heat sentry feature activation, the corresponding LED will stop blinking and remain constant. The unit has exited the heat sentry feature. WOLF COOKTOP VENTILATION HOOD USE & CARE ACCESSORIES Optional accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. HALOGEN LIGHTING The Wolf 30" (762) wall hood requires two halogen bulbs (type T4, 12V, 20W). The Wolf 36" (914) wall hood requires three halogen bulbs (type T4, 12V, 20W). The Wolf 42" (1067) Island hood requires four halogen bulbs (type T4, 12V, 20W). Replacement halogen light bulbs for the Wolf cooktop wall and island hoods are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. HALOGEN BULB REPLACEMENT Be sure that the bulb is cool before replacing. Halogen bulbs get hot instantly and adjacent parts may retain heat. 1) Turn ventilation hood blower and lights off. 2) Remove filters from under...

Otros modelos de este manual:
Utensilios de cocina - CTWH30 (207.27 kb)
Utensilios de cocina - IH4227 (207.27 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría