95mm(3.5in.). 3. Place it at the center of the tray and set it in a cavity. 4. Close the door and operate the oven. 5. Measure the leakage by using Microwave Energy Survey Meter with dual ranges, set to 2450MHz. 1) Measured radiation leakage must not exceed the value prescribed below. Leakage for a fully assembled oven with door normally closed must be less than 4mW/cm2. 2) When measuring the leakage, always use the 5cm(2in.) space cone with probe. Hold the probe perpendicular to the cabinet and door. Place the space cone of the probe on the door, cabinet, door seem, door viewing screen, the exhaust air vents and the suction air vents. 3) Measuring should be in a counter-clockwise direction at a rate of 1 in./sec. If the leakage of the cabinet door seem is unknown, move the probe more slowly. 4) When measuring near a corner of the door, keep the probe perpendicular to the areas making sure the probe end at the base of the cone does not get closer than 2 in. from any metal. If it does not, erroneous reading may result. 17 3. COMPONENT TEST PROCEDURE • High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle. • It is neither necessary nor advisable to attempt measurement of the high voltage. • Before touching any oven components or wiring, always unplug the oven from its power source and discharge the capacitor. 1. High voltage transformer (1) Remove connections from the transformer terminals and check continuity. (2) Normal readings should be as follows: Secondary winding ...................Approx. 110.±10% Filament winding....................................Approx. 0. Primary winding .....................................Approx. 1. 2. High voltage capacitor (1) Check continuity of capacitor with meter on the highest OHM scale. (2) A normal capacitor will show continuity for a short time, and then indicate 10M. once the capacitor is charged. (3) A shorted capacitor will show continuous continuity. (4) An open capacitor will show constant 10M.. (5) Resistance between each terminal and chassis should be infinite. 3. High voltage diode (1) Isolate the diode from the circuit by disconnecting the leads. (2) With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals. Reverse the meter leads and again observe the resistance reading. Meter with 6V, 9V or higher voltage batteries should be used to check the front-back resistance of the diode, otherwise an infinite resistance may be read in both directions. A normal diode’s resistance will be infinite in one direction and several hundred K. in the other direction. 4. Magnetron For complete magnetron diagnosis, refer to “Measurement of the Microwave Power Output”. Continuity checks can only indicate and open filament or a shorted magnetron. To diagnose for an open filament or a shorted magnetron. (1) Isolate magnetron from the circuit by disconnecting the leads. (2) A continuity check across magnetron filament terminals should indicate 0.1. or less. (3) A continuity check between each filament terminal and magnetron case should read open. 5. Fuse If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and monitor switch before replacing the blown fuse. In case the fuse is blown by an improper switch operation, replace the defective switch and fuse at the same time. Replace just the fuse if the switches operate normally. 18 WIRING DIAGRAM 19 20 EXPLODED VIEW AND PARTS LIST 1. DOOR ASSEMBLY Refer to Disassembly and assembly. 2. CONTROL PANEL ASSEMBLY Refer to Disassembly and assembly. 3. TOTAL ASSEMBLY 4 Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(NO PART CODE PART NAME DESCRIPTION Q'TY A00 3511714420 DOOR AS KOR-63D59A 1 3511714450 DOOR AS KOR-63F59A 1 B00 3516720620 CONTROL-PANEL AS KOR-63D79S 1 3516720630 CONTROL-PANEL AS KOR-63F79S 1 F01 3510805000 CABINET SECC T0.5 1 F02 7112401011 SCREW TAPPING T1 TRS 4*10 MFZN 3 F03 3516109000 CAVITY WELD AS CAVITY WELD AS 1 3516109600 CAVITY JOINT AS KOR-63150S 1 F04 7112401011 SCREW TAPPING T1 TRS 4*10 MFZN 1 F05 7122401211 SCREW TAPPING T2S TRS 4*12 MFZN 1 F06 7122401211 SCREW TAPPING T2S TRS 4*12 MFZN 1 F07 7112401011 SCREW TAPPING T1 TRS 4*10 MFZN 2 F08 35113AEQ0D CORD POWER AS 3X0.75 70X70 100-RTML 1 F09 7112401011 SCREW TAPPING T1 TRS 4*10 MFZN 1 F10 7122401211 SCREW TAPPING T2S TRS 4*12 MFZN 1 F11 4415D67620 FUSE 250V 12A 65TS 1 4415D67120 FUSE 250V 12A MDA 1 F12 3518606200 NOISE-FILTER DWLF-M12 1 F13 7121403011 SCREW TAPPING T2S PAN 4X30 MFZN 2 F14 3963512310 MOTOR SHADED POLE 230V 20W MW10CA-M02 1 F15 3512517000 GUIDE WIND PP 1 F16 3511800300 FAN PP+30%GLASS 1 F17 3518002400 MAGNETRON 2M218J(F) 1 F18 3516004000 SPECIAL SCREW T2 BOLT FLANGE 5X12 DACRO 1 F19 7S422X...

Otros modelos de este manual:
Los hornos de microondas - KOR-63F70S (677.75 kb)
Los hornos de microondas - KOR-63F79S (677.75 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría