Fabricar: Sony
Tamaño del archivo: 695.61 kb
Nombre del archivo: 4229182111.pdf
|
Otros manuales para este modelo:
Resumen del manual
If “L-SYNC” does not appear during recording, turn on the Level Synchro Recording as follows. Track numbers are automatically marked when the input signal is continuously below a certain level for more than two seconds and then exceeds that level. 4,5 4,5 4,5 3,6 1 2 1 Press FUNCTION repeatedly until “AM” or “FM” appears. To record from other components connected to this system, select “TAPE” or “ANALOG IN”. 2 Press MD z REC to stand by for recording. 3 Press MENU/NO repeatedly until “Setup Menu” appears. 4 Press – or + repeatedly until “T.Mark Off” or “T.Mark LSync” appears, then press ENTER/YES. 5 Press – or + repeatedly until “T.Mark LSync” appears, then press ENTER/ YES. “L-SYNC” lights up. 6 Press MENU/NO. To continue and record, follow the procedures described on the various recording pages. To stop recording Press x. To change the trigger level for automatic track marking Do the procedure below to change the signal level that triggers automatic track marking. 1 Press MENU/NO during recording pause. “Setup ?” appears, then press ENTER/YES. 2 Press – or + repeatedly until “LS(T)” appears, then press ENTER/YES. 3 Press – or + repeatedly to select the level, then press ENTER/YES. You can set the level at any value between –72 dB and 0 dB, in 2 dB steps. 4 Press MENU/NO. To cancel automatic track marking Press – or + repeatedly until “T.Mark Off” appears in step 5 above, then press ENTER/YES. “L-SYNC” disappears. When “L-SYNC” is off, a track number is marked only at the beginning of each recording. continued The MD Deck — Recording Marking track numbers (continued) Marking track numbers at a specific point during recording — Track Mark You can mark track numbers at any time during recording, regardless of the type of sound source. MD z REC , Press MD z REC during recording at the point you want to add a track mark. The tracks following the added one are renumbered. Making a space between tracks 3 seconds long — Smart Space The Smart Space function lets you make the blank spaces between tracks 3 seconds long automatically while making a digital recording from a CD. For other types of recording, if the Smart Space function is on and there is no sound input for about 3 seconds or more (but less than about 30 seconds) while recording, the MD deck replaces this silence with a blank of about 3 seconds and continues recording. No sound input for less than 30 seconds Off On Replaced with a blank of 3 seconds and recording continues Auto Cut: When the Smart Space function is on, if there is no sound input for about 30 seconds or more, the MD deck replaces this silence with a blank of about 3 seconds and enters recording pause. No sound input for 30 seconds or more Off On Replaced with a blank of 3 seconds and recording pauses Setting Smart Space to on 3,4 2,5 3,4 3,4 1 1 Press MD z REC to stand by for recording. 2 Press MENU/NO repeatedly until “Setup Menu” appears. 3 Press – or + repeatedly until “S.Space Off” (or “S.Space On”) appears, then press ENTER/YES. 4 Press – or + repeatedly until “S.Space On” appears, then press ENTER/YES. 5 Press MENU/NO. To continue and record, follow the procedures described on the various recording pages. If there is an extended silence of less than about 30 seconds during recording, “Smart Space” appears, and the MD deck replaces the silence with a blank of about 3 seconds and continues recording. If there is no sound input for about 30 seconds or more during recording, “Auto Cut” appears, and the MD deck replaces the silence with a blank of about 3 seconds and switches to recording pause. Press MD Nto restart the recording. To turn off Smart Space and Auto Cut functions Press – or + repeatedly until “S.Space Off” appears in step 4 above , then press ENTER/YES. Tip The Smart Space and Auto Cut functions are factory set to on. If you turn off the system or disconnect the power cord, the MD deck will retain the last setting (S.Space On or Off). The MD Deck — Recording Adjusting the recording level When recording on an MD, you can adjust the recording level to the desired volume. You can adjust the recording level not only when making an analog recording, but also when making a digital recording from a CD, etc. 4,6 3,7 4,5 4,5 8 2 1 Prepare the desired sound source to record and start play. 2 Press MD z REC to stand by for recording. 3 Press MENU/NO repeatedly until “Setup Menu” appears. 4 Press – or + repeatedly until “LevelAdjust?” appears, then press ENTER/YES. 5 Press – or + to adjust the recording level. While monitoring the sound, adjust to the optimum level while making sure that “OVER” does not appear in the display at the loudest portion. Adjust the level so that “OVER” does not appear 6 Press ENTER/YES. 7 Press MENU/NO. 8 Press xto cancel recording pause. 9 When a CD or other sound source is playing, stop playback. To continue and record, follow the procedures described on the various recording pages. Tips • You can also adjust the recording level during recording. • Once a...
Otros modelos de este manual:- ()