These distances are based on a 6’ target. A 6’ target fits between the numbered baseline (the three short horizontal lines directly next to the numbers) and the main horizontal line. If the 6’ target fits between the 1 and the right horizontal post of the main line the target is 100 yards away. If the same target fits between the 2 and the right post of main line the target is 200 yards away. The same is with the three, the target is 300 yards away. Aries 390 reticle gives a clearly aiming point, even when hard-to-see game blends into the background. Thinner posts and crosshairs center section covers a minimum of the target and allow for less target coverage, making precision shots on small targets easy. Heavy posts stand out against cover and leads your eye directly to the center intersection. The result is fast precision aiming. Ifa6’targetfitsbetweenthesetwolinesthenthetargetis100yardsawayIfa6’targetfitsbetweenthesetwolinesthenthetargetis200yardsawayThethinlinescorrespondto1.25yardsat100yardsdistance CLEANING THE EYEPIECE You may need to clean the eyepiece of the riflescope from time to time in order to guarantee top performance. When you receive your riflescope you should check for dust on the eyepiece of the unit. First you will need to remove the eyepiece. To do that you will need to initially loosen the 2 set screws that can be found on the base. Then unscrew the eyepiece counter-clockwise to remove it. NOTE: You do not have to remove the set screws completely, they are very small and easy to misplace. CAUTION: Use only Photographic lens cleaning tissue on these surfaces. Be careful not to scratch or smudge any of these surfaces. When using compressed air to blow dust away, make sure to avoid inverting the can while spraying. This can cause frozen propellant to exit the can, which can cause serious problems with the glass and phosphor screen. WARNINGS AND CAUTIONS • Always remember to turn off the Aries scope when it is not in use. If you do not plan on using your aries scope for a period of more than 10 days, you should remove the batteries. • Keep lens cap/daylight filter on when not in use. • Avoid contact with dust, steam, and gas. • The Aries scope are not harmful to the user or the environment. • Do not disassemble except to clean the front lens and the eyepiece: it will void your warranty. • Evaluate the scopes function by looking through it in a lit environment with the daylight filter lens cap on. Never use in TROUBLESHOOTING daylight without the daylight filter lens cap on. Do not surpass ten minutes of testing. • Never point the Aries scope at a bright light source. If the scope shuts off automatically after directing it at a bright light source, turn the unit off and wait 1 -2 minutes before turning the unit back on. • Adverse atmospheric conditions such as fog, smog, or haze and a lack of ambient light (moon or starlight) may diminish the effective viewing distance. All technical data for this unit was compiled in a controlled environment. Q: Flashes, flickers, or clicking occur while operating S: If it occurs within the first five minutes of inserting new batteries, it is normal and the device will resume normal operation soon thereafter. If it occurs for more than 10 minutes, contact your dealer or other authorized service representative for service instructions. Q: Dark spots on screen. S: This may be dust on the lens, please clean according to instrutions. They may also be Cosmetic blemishes in the intensifier tube which are a by-product of the manufacturing process. This is normal and will not affect the life or performance of the unit. Q: Image not clear. S: Adjust focus ring. If problem persists, increase viewing distance Q: Fixed-pattern noise in a honeycomb shape. S: Usually a cosmetic blemish characterized by a faint honeycomb-type pattern. This usually occurs when viewing very bright lights. Adjust the potentiometer, to reduce brightness. Q: A pattern of dark thin lines which look like chicken wire. S: Turn on illuminator, if purchased. If illuminator doesn’t brighten image, replace batteries. If problem persists, contact ATN for service instructions. PRODUCT WARRANTY This product is guaranteed to be free from manufacturing defects in material and workmanship under normal use for a period of 2 (two) years from the date of purchase for Aries 390 “Paladin” and 3 (three) years from the date of purchase for Aries 6900/7900/8900 “Crusader”. In the event a defect that is covered by the foregoing warranty occurs during the applicable period stated above, A...

Otros modelos de este manual:
Instrumentos de óptica - 390, 6900, 7900, 8900 (194.43 kb)
Instrumentos de óptica - 7900 (194.43 kb)
Instrumentos de óptica - Aries 6900 (194.43 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría