Iniciar sesión:
Votos - 5, Puntuación media: 3.6 ( )

Manual de usuario ATN, modelo Aries 6900

Fabricar: ATN
Tamaño del archivo: 194.43 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


1+ LIT. • “Red on Green” reticle system with 1/8 inch @ 100yards adjustment • 4X magnification with new F:1.4, f90mm lens • New, detachable most powerful in the industry 450mWt Infrared Illuminator with dedicated windage and elevation adjustments. • New Titanium mounting system • Dimensions: 12”x4”x2.8” • Weight: 2.8 lbs. ARIES 6900/7900/8900 “CRUSADER” • Top-notch performance with pro-oriented design • 5X magnification, F:1.4, f90mm lens • “Red on Green” reticle system with 1/8 inch @ 100yards adjustment • New Titanium mounting system • Prime Select US 2nd Gen. (6900), Prime Select US 3rd Gen. (7900) or 4th Gen.(8900) tubes used • Automatic brightness control(ABC) for tube protection • Dimensions: 12”x4”x3” • Weight: 2.8 lbs. • Made in USA PREPARATION FOR OPERATION Before getting started make sure to follow these steps: • Install the battery into its housing with the polarity order shown on the main body of the unit. • Switch on the Aries scope with the protective tens cover still attached to the tens. • Make sure that the green luminance of the light intensifier tube is present. • Observe the scene, and adjust the diopter and/or lens for optimal image clarity. • You may now enter a dark environment or simply shut the lights off in order to darken the room. • Next, remove the lens cap/daylight filter. • Observe the scene, and adjust the front lens for ideal focus. • Finally, you may want to turn the infra red (IR) illuminator on. Notice the ability of the Aries scope to see in total darkness with the aid of the IR illuminator. Batteryinstallation OPERATING MOUNTING 1. Slightly loosen the horizontal and vertical fixing screws on the 7/8” weaver rail built into the scope. 2. Place the scope on the dovetail mount of the fire arm making certain that the mount aligns with the receptor attachment screw groove. Adjust as necessary. 3. Tighten the horizontal fixing screws. NOTE: Receptor attachment screws may need to be tightened after continuous shooting. MOUNTING SYSTEM The ATN Night Vision Riflescopes Mounting System allows to change the position of the riflescope flexibly on the weapon in relation to a shooter in combination with the fixed positions already available on the weaver rail. For this purpose in the base of the mounting bracket there is a rail with a fixing projection. There are three grooves in the mounting bracket for mounting this rail. Besides it is possible to change the position of the rifle- scope additionally by 1/3 of inch. For doing this one needs to about-face the rail. WeaverrailGroovesRailwithafixingprojectionScrews To change the position of the riflescope on the weaver rail additionally follow the steps mentioned below: 1. Unscrew the two screws, which attach the rail to the mounting bracket. 2. Take the rail out of the groove. 3. About-face the rail in case of necessity. 4. Place the rail into another groove. 5. Fix the rail with the two screws. NOTE: If the rail is not taken out easily, screw up tight one of screws into the threaded aperture in the middle of a fixing projection of the rail. Continue rotation of the screw. Thus the screw will push out a rail from a groove. BRIGHTNESS ADJUSTMENT By rotating the “R” handle you may adjust the reticle’s brightness. Adjustment could be easily seen if you look trought the scope while adjustement. ReticleBrightnessAdjustment(MK6900) ReticleBrightnessAdjustment(MK390) WINDAGE AND ELEVATION The vertical and horizontal adjustments for the Aries can be achieved by turning the elevation and windage adjustment mechanisms (remove dust caps first). Each click equals to 1/8 inches at 100 yards. When reaching the maximum of rotation do not use force. WindageElevation FOCUSING To focus your riflescope you will need to adjust the diopter first thing. Simply turn the diopter clockwise until it stops. Then, while looking through the diopter at a subject, slowly turn the diopter back counter clockwise until the grain in the image is sharp. NOTE: We suggest that you focus the diopter during daylight with the filter on. Next, focus the front lens until the image and the grain are both sharp. When you are in the low-light conditions and the daylight filter is off you may focus the front lens to receive a sharp image, the diopter should not be adjusted. NOTE: The front lens should be readjusted as you view objects at different distances. IR ILLUMINATOR Infra-red (IR) Illuminators are common for night vision technology. The IR light greatly enhances the performance of your Aries scope, while remaining almost totally invisible to the ...

Otros modelos de este manual:
Instrumentos de óptica - 390, 6900, 7900, 8900 (194.43 kb)
Instrumentos de óptica - 7900 (194.43 kb)
Instrumentos de óptica - 8900 (194.43 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría