Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Frigidaire, modelo 66166042

Fabricar: Frigidaire
Tamaño del archivo: 489.03 kb
Nombre del archivo: 66166042enaen.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


4. You can also use the FAN button to change the fan speed to HIGH( ) or LOW( ). The indicator light will show the setting you have selected. A higher fan speed will result in quicker moisture removal. 5. The FILTER RESET light will illuminate after 250 hours of operation. At this time refer to the Care and Cleaning section to remove and clean the filter. Once the filter has been cleaned , to extinguish the light simply press the FILTER button. 5 6. The TIMER function enables you to either start or stop the unit in the choice of 2 or 4 hours.If the unit is running then selecting TIMER at 2 hours will turn the unit off after 2 hours.If the unit is off pressing the TIMER button and selecting say 4 hours, the unit will turn on after 4 hours and remain working in the selected mode.The POWER indicator must be lit to make sure power is being supplied to the unit. 7. To shut the unit down, press the ON/OFF button. Note: the power indicator will still be lit when the unit is turned off. Only removing the plug will extinguish these lights. FAULT CODES If the display reads "F1" or "F2", a sensor has failed. Contact your Authorized Frigidaire Service Center. 6 REMOVING COLLECTED WATER 1. Emptying the Bucket: a. When the bucket is full the unit will shut down and the BUCKET FULL indicator light will illuminate. b. Do not move the unit at this point otherwise water may spill on the floor. c. Press sides of bucket gently to unclip the bucket from the unit. d. Remove the bucket as shown in the photographs below and empty the bucket. e. Replace the empty bucket back into the unit and once seated correctly the unit will start up again. 7 f. You should hear a click when the bucket is in the correct position. ................................................................................................................................................................................ ..........................................................diagram.. 2. Continuous Drainage: a. For constant drainage operation, you will need a garden hose and a drain nearby to discharge the water into. b. Remove the bucket from the unit and set aside. c. Lift up the side flap located on the left side of the unit as looking from the front. (fig.1) d. Insert the female threaded end of the hose through the opening. (fig.2) e. Screw the garden hose onto the threaded portion of the tray underneath the bucket opening. (fig.3) f. Make sure the hose is secure so there are not leaks. g. Direct the hose toward the drain making sure that there are no kinks that will stop the water flowing. h. Place the end of the hose into the drain. i. Place the bucket back in the unit and make sure that it is located correctly. (fig.4) j. Select the desired humidity setting and fan speed on the unit for continuous draining to start. Note: If the unit stops operating check that the bucket full light is illuminated. If it is remove the bucket and empty the contents and then check the seal between the hose and the drip tray. If there is a small leak then replace the hose gasket and re-tighten the hose. CARE AND CLEANING 1. Filter a. Remove the filter every two weeks based on normal operating conditions. .................................................................................... pull filter downwards. c. Wash the filter with clean water then dry. fig.1 fig.4fig.3fig.2 d. Re-install the filter, replace Bucket. 2. Cabinet a. Dust cabinet with an oil-free cloth, or using a damp cloth. b. Vacuum grill using brush attachment. 3. Water Bucket a. Clean bucket with warm water and detergent. STORAGE When unit is not in use unplug and use the cord wrap shown for your model type. 1. 2. 8 Before calling for service, review this list. It may save you time and expense. This Avoid Service Checklist list includes common occurrences that are not the result of defective workmanship or materials in this appliance. OCCURRENCE SOLUTION DEHUMIDIFIER D DDOES N NNOT O OOPERATE. Plug is disconnected from outlet. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. The dryness level you selected has been reached. Dehumidifier automatically shuts off when selected amount of moisture has been removed from the air. If you want to remove more moisture, Select 'CONTINUOUS' by using the humidity button or knob. After the dehumidifier starts, reset the control to the desired setting. Bucket not installed properly. See “ Removing Collected Water.” Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this occurs. Empty bucket and return bucket to position. Dehumidifier is not turned on. Turn unit on. DEHUM IDIFIER R RR UNS T TT OO M MM UCH. W indows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside. Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate. Air movement through dehumidifier is blocked. Gril...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría