Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Broan, modelo HEPA 4000

Fabricar: Broan
Tamaño del archivo: 4.67 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Route the cable to the unit. 7. Remove the front 8’’ oval port (A) and the front panel (B) of the unit by unscrewing their retaining screws. CAUTION Keep control low voltage wiring at least 1 foot (305 mm) away from motors, lightning ballast, light dimming circuit and power distribution panel. Do not route control wiring along with house power wiring. Avoid poor wiring connections. Failure to follow these practices can introduce electrical interference, which can cause erratic control operations. - 30 - VC0051 VC0052 1 2 3 4 5 2 3 4 1 5. CONTROLS (CONT’D) VO0018 VO0019 A B 5. CONTROLS (CONT’D) 5.4 INSTALLATION OF THE OPTIONAL WALL CONTROLS (CONTROLS C12 / CM AND C34 / CMR) (CONT’D) 8. Using a small rod, pierce a hole through the unit at the end of the wire channel. (See picture beside.) Splice back the end of the cable to access the 4 wires. Remove the insulated sleeve of each wire ends. Insert the end of the cable through the unit, using the small hole previously done. VD0088 9. In order to access the unit PCB terminals, remove the side door located on the electrical box and punch out its knock out. Run the cable through the knock-out hole and connect each wire in their corresponding terminal (YELLOW in ‘’Y’’, RED in ‘’R’’, GREEN in ‘’G’’and BLACK in ‘’B’’). NOTE: Push forward slightly on the little tabs (1) to ease insertion of each wires. See picture beside. 10. Reinstall the side door on the electrical box and the 8’’ oval port on the unit. VE0049 1 11. Route the wire through its channel and reinstall the front panel on the unit. See picture beside. VD0089 12. If the installation is not completed, return to Section 4 on page 19. If the installation is completed, plug the unit. NOTE: When using an optional wall control, the main switch on the unit must always be positioned to NORMAL/REMOTE. - 31 5. CONTROLS (CONT’D) 5.5 OPERATING C12 / CM CONTROL 5.5.1 C12 / CM CONTROL DESCRIPTION POWER INDICATOR: LIGHTS UP WHEN SLIDE SWITCH IS ON NORMAL OR BOOST POSITION. FILTER MAINTENANCE INDICATOR: FLASHES EVERY MINUTE TO INDICATE IT IS ON DUTY. FLASHES EVERY SECOND WHEN ITS TIME TO REPLACE PREFILTER.SEE BIANNUAL MAINTENANCE IN SECTION 6. LIGHTS UP WHEN ITS TIME TO REPLACE FILTER AND PREFILTER.SEE ANNUAL MAINTENANCE IN SECTION 6. VC0054 OFF: UNIT IS OFF. NORMAL: UNIT IS OPERATING ON NORMAL SPEED. BOOST: UNIT IS OPERATING ON HIGH SPEED. RESET FILTER HOLE: ONCE THE MAINTENANCE DONE, RESET THE FILTER MAINTENANCE INDICATOR BY CAREFULLY INSERTING A SMALL ROD (EG: PAPER CLIP) IN THE RESET FILTER HOLE, DURING 1 SECOND.THE FILTER MAINTENANCE INDICATOR WILL TURN OFF. 5.5.2 USING C12 / CM CONTROL • OFF: To stop the unit, slide the button on this position. • NORMAL: For a day-to-day usage, slide the button on this position. The unit then will operate on normal speed. • BOOST: For a high speed operation, slide the button on this position. Generally used when extreme conditions occur, eg.: parties, smokers, etc. - 32 5. CONTROLS (CONT’D) 5.6 OPERATING C34 / CMR CONTROL 5.6.1 C34 / CMR CONTROL DESCRIPTION RECIRCULATION INDICATOR: FRESH AIR INDICATOR: LIGHTS UP WHEN SLIDE LIGHTS UP WHEN SLIDE SWITCH IS ON SWITCH IS ON NORMAL OR BOOST POSITION. FILTER MAINTENANCE INDICATOR: FLASHES WHEN IT IS TIME TO REPLACE PREFILTER AND WASH CORE FILTERS. SEE BIANNUAL MAINTENANCE IN SECTION 6. LIGHTS UP WHEN IT IS LIGHTS UP WHEN SLIDE TIME TO REPLACE FILTER SWITCH IS ON NORMAL AND PREFILTER AND POSITION.UNIT IS OPERATING CLEAN CORE AND CORE ON NORMAL SPEED. FILTERS.SEE ANNUAL MAINTENANCE IN SECTION 6. VC0048 NORMAL INDICATOR: RESET FILTER HOLE: ONCE THE MAINTENANCE DONE, RESET THE FILTER MAINTENANCE INDICATOR BY CAREFULLY INSERTING A SMALL ROD (EG: PAPER CLIP) IN THE RESET FILTER HOLE, DURING 1 SECOND.THE FILTER MAINTENANCE INDICATOR WILL TURN OFF. BOOST INDICATOR: LIGHTS UP WHEN SLIDE SWITCH IS ON BOOST POSITION.UNIT IS OPERATING ON HIGH SPEED. RECIRCULATION.UNIT IS OPERATING ON NORMAL SPEED. 5.6.2 USING C34 / CMR CONTROL • OFF: To stop the unit, slide the button on this position. • NORMAL: For a day-to-day usage, slide the button on this position. The unit then will operate on normal speed. • BOOST: For a high speed operation, slide the button on this position. Generally used when extreme conditions occur, eg.: parties, smokers, etc. • RECIRCULATION: For a normal speed operation, without exchanging air with the outside, slide the button on this position. This mode is recommended in high humidity days (rain, heat wave). Also, use it when the outside temperature is extremely cold and/or the inside air is too dry. It can be used also to recirculate the heat coming from a wood stove throughout the house, or the fresh air from a cooling system. - 33 6. MAINTENANCE WARNING Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source. 0 ! 6.1 BIANNUAL MAINTENANCE (ESSENTIAL) If your unit is equipped with an optionnal wall control (C12 / CM or C34 / CMR) you should perform this maintenance w...

Otros modelos de este manual:
Placa - HEPA 2000 (4.67 mb)
Placa - HEPA 1000 (4.67 mb)
Placa - HEPA 3000 (4.67 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría