|
Resumen del manual
AFGS1095 CONTENTS INSTALLATION Safety Notices General Information Contents List & Part Identification Important Notices Statutory Requirements Certification Technical Data Gas Fire Dimensions Installing The Stove Preparation of the stove Stove Location Shelf Clearances Flue System Fitting The Flue Spigot And Blanking Plate Rear / Top Flue Options Connecting The Gas Supply Pressure Test Sequence Fitting & Arranging The Coals Fitting & Arranging The Logs NG Fitting & Arranging The Logs LPG Installation of Remote Control System Commissioning The Stove Fire Testing Installation Check List 3 3-4 5 6 6 6 7 7 7 8 8 9 10 11 11-12 13 13 14-15 15-16 16-17 18-21 22 22-23 24 SERVICING Replacement Of The Glass Frame 25-26 Burner & Valve Assembly Removal 26 Annual Service 27 Cleaning Outer Surfaces 27 Fault Diagnosis 28 Annual Service Record 29 USER INSTRUCTIONS Lighting & Controlling The Fire 32-33 Cleaning Outer Surfaces 33 Operation of Remote Control 34-37 Important Notices 38 Statutory Requirements 38 Certification 38 Shelf Clearances 39 SPARE PARTS General Components 40-42 Options & Accessories 43 GUARANTEE 44 Final Factory Checklist 46 Aarrow Sherborne GSL CF INSTALLATION INSTRUCTIONS References in this manual to British Standards and Statutory Regulations and Requirements apply only to the United Kingdom. For Ireland the rules in force must be used. Before installation, check that the local distribution conditions, nature of the gas, pressure and the adjustment of the appliance are compatible. The manual is an important part of the appliance and must by law be handed to the end user on completion of the installation. SAFETY NOTICES • Do not attempt to burn rubbish or any other material in this appliance. • Do not use the appliance if the glass is cracked or broken. • Do not make any unauthorised modifications to the appliance. • It is recommended that the stove be guarded to protect the young and infirm using a fireguard complying with BS8423:2002. • Coal / Log set -The coal/log set contains Refractory Ceramic Fibres (R.C.F), which are man made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to the eyes, skin and respiratory tract. Care must be taken when handling these items to ensure the release of dust particles is kept to a minimum. To ensure that the release of fibre from these items is kept to a minimum, during installation and servicing it is recommended that a vacuum cleaner fitted with H.E.P.A. filters is used to remove any dust, soot or any other debris accumulated in and around the appliance. This should be performed before and after the installation. It is recommended that any replacement item(s) are not broken up but sealed within a heavy duty polythene bag and clearly labelled "R.C.F. waste". This is not classified as "hazardous waste" and may be disposed of at a tipping site licensed for the disposal of industrial waste. Protective clothing is not required when handling these items but it is recommended that gloves are worn and normal hygiene rules are followed. Always wash your hands before eating or drinking. • In the event of a gas emergency, consult the telephone directory and ask for your local gas supplier. Guide to manual handling • Always obtain assistance when lifting the appliance. • When lifting always keep your back straight. Bend your legs not your back. • Avoid twisting at the waist. It is better to reposition your feet. • Avoid upper body/top heavy bending. Do not lean forwards or sideways when handling the fire. • Always grip with the palms of your hands. Do not use fingertips for support. • Always keep the stove as close to the body as possible. This will minimise the cantilever action. • Use gloves to provide additional grip. GENERAL INFORMATION 1. General Note All materials and equipment used in the installation of this stove should be fit for the purpose, be of suitable quality and workmanship and should comply with the applicable British Standards, building regulations and rules in force. 2. Ventilation No purpose provided ventilation is normally required. 3. Flue Type The stove is suitable for flue options with a minimum diameter of 127mm (5”) and have a minimum effective height of 3 metres (10ft) see page 11 to 12. 4. Hazardous Materials Asbestos, hazardous or any banned materials have not been and will not be included in this product. Aarrow Sherborne GSL CF INSTALLATION INSTRUCTIONS 5. Stove location See installation instructions on page 7. 6. Packed details For packed weight see packaging labels. Fig 1 7.Unpacking note When the stove is unpacked ensure no damage occurs if placed on the carpet as it can leave indentation marks. For contents list see page 5. 8. Fit for purpose All materials, appliances and equipment used should be fit for purpose, be of suitable quality and workmanship and should comply with the applicable British Standard. 9. Data Label Plate. The data label plate is fixed to the underside of the valve bracket a...
Otros modelos de este manual:Placa - Gas Stove (3.73 mb)