Manual de usuario Aarrow Fires, modelo Gas Stove

Fabricar: Aarrow Fires
Tamaño del archivo: 3.73 mb
Nombre del archivo: 1af5bae4-f9ab-4d04-8c5f-a20c407044bb.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


All of the smoke should be drawn into the fire. If this does not occur the appliance must be disconnected and the flue checked. Step 5. If there is an extractor fan in any room, this must be turned on and any doors between it and the fire left open, repeat the spillage test. Repeated operation of the spillage monitoring system whereby the OSD (oxygen sensing device/spillage monitoring system). If their is a problem with the ODS pilot going out after the stove has operated satisfactory, this indicates a possible flue draw problem. Seek expert advise from a qualified engineer. Warning: The spillage monitoring system, consists of a special oxygen sensing device (OSD) pilot and is a safety feature required by law. It must not be adjusted or put out of action by the installer. If the spillage monitoring system or any of its parts are to be replaced, only original manufacturers parts must be used. Fig. 19a Note: The fire will give off non-toxic fumes when first used. This is perfectly normal it will disappear after the first few hours. Once the spillage test is complete open windows and doors to ventilate the area. SELF LEVELING REAR FEET Once the stove is in position on the hearth, working on the rear legs, simply loosen the pozi screw and rotate the inner ‘pear’ shaped adjuster to touch the hearth. Re-tighten the screw and repeat for the other side. Fig. 19b Aarrow Sherborne GSL CF INSTALLATION INSTRUCTIONS Advise the end user 1. That there will be an odour from the stove when the stove is first lit and is non-toxic. It is advised that the stove is initially run with the room well ventilated to disperse the fumes. 2. How the valve controls operate and how to light the pilot. 3. Advise about leaving pilot on. 4. That the stove is fitted with two safety devices, one cuts off the stove if for any reason the gas supply is turned off - A flame failure devise. The second will cut the stove off if there is inadequate flue draw for example a blockage in the chimney. If this occurs the stove should not be re-lit until the stove and flue have been checked by a qualified gas engineer. 5. To read the users instructions before using the stove. 6. The stove must never be used if the glass is cracked or broken. 7. Explain that the working surfaces of the stove will get hot and that no combustible materials including clothing, furniture and furnishings (including curtains) must not be placed within one metre of the stove. Leave the instruction manual with the end user Aarrow Sherborne GSL CF INSTALLATION INSTRUCTIONS CHECKLIST Hearths, Fireplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002. 1. Building address, where work has been carried out....................................................................................................................................... ......................................................................................................................................................................................................................... 2. Identification of hearth, fireplace chimney or flue 3. Firing capability: solid fuel/gas/. 4. Intended type of appliance. State model and output. 5. Ventilation provisions for the appliance: State type and area of permanently open vents. 6. Chimney or flue construction a) State the type or make and whether new or existing. b) internal flue size (and equivalent height, where calculated - natural draught gas appliances only). c) If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used. d) If an existing chimney has been refurbished with a new liner, type or make of liner fitted. e) Details of flue outlet terminal and diagram reference. Outlet Details: Complies with: f) Number and angle of bends. g) Provision for cleaning and recommended frequency. 7. Hearth. Form of construction. New or existing? 8. Inspection and testing after completion Tests carried out by: Tests and results Flue visual inspection sweeping coring ball smoke Appliance (where included) spillage I/we the undersigned confirm that the above details are correct. In my opinion, these works comply with the relevant requirements in Part J of Schedule 1 to the Building regulations. Print name and title....................................................................................................Profession.......................................................................... Capacity......................................................................................................................Telephone.......................................................................... Address.....................................................................................................................................

Otros modelos de este manual:
Placa - Gas Stove (3.73 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría