Warning: Do not connect to any other type of Smoke/Heat Alarm. Doing this may damage the alarms and could result in a shock or fire damage. Note 1: An alarm with battery back-up (i.e. Ei 141,144,146,161,164,166) will continue to operate during L IC N R Y N IC L TO EASI-FIT SMOKE ALARM MOUNTING PLATE TO OTHER SMOKE/HEAT ALARMS (IF PRESENT) NEUTRAL INTERCONNECT LIVE REMOTE CONDUIT TO CONTROL PANEL Ei173 N IC L -BLUE -WHITE -BROWN -RED -YELLOW -SPARE TERMINAL Figure 1 1. Choose the mounting position following the siting instructions in the Smoke Alarm leaflet. Remove the power from the circuit you plan to use. 2. Where the incoming mains and interconnect wires are on the surface of the ceiling or wall the appropriately sized ducting/ conduit must be chosen to mate with the unit. 3. The low voltage wiring from the control panel must not be run in the same conduit as the mains/interconnect wires. 4. Using a sharp knife remove material from the appropriate knockouts making sure that there is no gap, either where mated with the ducting/conduit or with the low voltage wires. There are three knockouts and one on the rear. 5. Screw the pattress to the surface using the two screws and plastic plugs supplied. 6. Figure 1 shows the connections. Connect the incoming live, neutral, and interconnect (from other smoke alarms if present) to the pre-wired connector block. The Pattress does not require an Earth. The three wires for connecting to the smoke alarm mounting plate are already wired to the pattress. Connect the red wire (remove the small piece of insulating tape first) from the control panel to the terminal marked “R” and the yellow wire to the terminal marked “Y”. The black and blue wires from the control panel are not used. They should both be connected to the spare terminal for extra strain relief. 7. Bring the mounting plate wires out through the hole in the mounting plate as shown in figure 2. Connect the three wires to the mounting plate terminals following the wiring colours specified in figure 2. Note: The white interconnect wire must be connected to the smoke alarm (even if there is only one smoke alarm on the system). SMOKE ALARM MOUNTING PLATE WIRING FROM PATTRESS Ei172/160 PLATE FIXING SCREWS Figure 2 INTERCONNECT (WHITE) LIVE (BROWN) NEUTRAL (BLUE) LIC N mains failure and will be able to signal the control panel if they sense fire. The control panel also has battery back-up, so that it too will operate during mains failure. 34 2. Testing your System After Installation 1. Turn on the AC mains power to the smoke alarm circuit. Check the continuous green light is visible on the smoke alarm cover. The red light on the unit will flash every 40 seconds. 2. Plug in the control panel mains adaptor (or turn on the AC mains if it is connected to a junction box). Slide the power switch on the side of the unit to the “on” position. Check the continuous green light on the control panel cover is visible. 3. Press the test button on the smoke alarm. The smo...
Otros modelos de este manual:Detector de incendios - Ei161 (125.25 kb)
Detector de incendios - Ei160 (125.25 kb)
Detector de incendios - Ei172 (125.25 kb)
Detector de incendios - Ei173 (125.25 kb)