Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Ei Electronics, modelo Ei172

Fabricar: Ei Electronics
Tamaño del archivo: 125.25 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The apparatus is not to be earthed, so no connection is to be made to terminals or wires marked with the letter E, the symbol or coloured green or green and yellow. Bring the low voltage wiring from the control panel to where the smoke alarm is to be located. Route all wires neatly and securely along the walls and ceilings. Note: Turning off the power switch on the Control Panel does not switch off the apparatus from the supply mains. The switch removes the AC and battery power from the Control Panel, but the mains transformer remains connected to the supply mains. Vibration Pad Plug the vibration pad into its locking socket on the control panel. Place the vibration pad under the pillow or mattress. It is important that the person in the bed can feel the vibration check it is sufficient to wake a person by lying on the bed and pressing the test button on the control panel -see also “Testing your system”. Some mattresses may not transmit sufficient vibration, and in these cases it should be fitted under the pillow. Note: During testing, or in an actual alarm situation, the pad pulses on and off for greater effect on sleepers. Mains Smoke Alarm Interface Pattress Ei 172/160 The pattress is used to mount the smoke alarm in its location, to connect it to the mains and interconnect wires, and to connect it to the wires from the Ei 173 control panel. (The connections from the non-isolated mains powered smoke alarms, to the low voltage control panel wires are through an opto-isolator in the Ei 172/160 for electrical safety). PATTRESS WIRING 8. Replace the wiring cover on the mounting plate. Slide the Smoke Alarm on to the mountig plate. Interconnecting Smoke Alarms A maximum of 12 Ei 140,141,144,145,146,161,164,166 Smoke/Heat Alarms may be interconnected to one Ei 172/160 unit. When one alarm senses fire all interconnected units will sound and the control panel will turn on the strobe light and vi- bration pad (See Smoke/Heat Alarm instruction leaflet for fur- ther details on interconnection wiring). Warning: Do not connect to any other type of Smoke/Heat Alarm. Doing this may damage the alarms and could result in a shock or fire damage. Note 1: An alarm with battery back-up (i.e. Ei 141,144,146,161,164,166) will continue to operate during L IC N R Y N IC L TO EASI-FIT SMOKE ALARM MOUNTING PLATE TO OTHER SMOKE/HEAT ALARMS (IF PRESENT) NEUTRAL INTERCONNECT LIVE REMOTE CONDUIT TO CONTROL PANEL Ei173 N IC L -BLUE -WHITE -BROWN -RED -YELLOW -SPARE TERMINAL Figure 1 1. Choose the mounting position following the siting instructions in the Smoke Alarm leaflet. Remove the power from the circuit you plan to use. 2. Where the incoming mains and interconnect wires are on the surface of the ceiling or wall the appropriately sized ducting/ conduit must be chosen to mate with the unit. 3. The low voltage wiring from the control panel must not be run in the same conduit as the mains/interconnect wires. 4. Using a sharp knife remove material from the appropriate knocko...

Otros modelos de este manual:
Detector de incendios - Ei161 (125.25 kb)
Detector de incendios - Ei166 (125.25 kb)
Detector de incendios - Ei160 (125.25 kb)
Detector de incendios - Ei173 (125.25 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría