Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Kidde, modelo P/N 900-0120

Fabricar: Kidde
Tamaño del archivo: 233.79 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The red LED (Alarm) will flash the same pattern. WARNING: For alarms equipped with 9V battery backup, when powered by battery backup the alarm will sound and flash only once every conserve battery life. If this unit is interconnected with other Kidde the amber LED (Initiating Alarm) of the unit which first detected the CO, will light and remain on until The other interconnected CO alarms will also alarm to warn you that CO was detected. Fire Alarm Indicator When an interconnected Kidde smoke alarm detects smoke, this unit will sound a smoke/fire alarm pattern of 3 long beeps, followed by 1 second of silence. This cycle repeats as long as smoke signal persists to alert you of the condition. If this happens, leave the premises immediately by your escape plan and call your local fire department. WARNING: This unit is not a smoke alarm and will not detect smoke or fire. It will only alarm for smoke/fire if it receives a signal from an interconnected Kidde smoke alarm. Note: A smoke/fire alarm will override a CO alarm condition. Operation Function LED Display Alarm Sound Unit Status Recommendation Normal operation Green LED constantly on None Normal AC operation (sensing no CO) and None with a good battery Normal operation Green LED flashes every 7 seconds None Normal DC operation on 9V battery backup Verify AC power is restored as soon as possible to conserve battery. Replace battery Carbon monoxide alarm Red LED flashes with beeps. Amber LED shows initiating alarm 4 quick beeps, 5 seconds silence, repeating Alarm condition. Dangerous concentrations of CO Refer to alarm procedure on Page 17 detected Smoke / fire alarm Red LED flashes with beeps. 3 long beeps, 1 second silence, Receiving signal from an interconnected Evacuate by your escape plan repeating smoke alarm detecting smoke Low battery Red LED flashes every One short “chirp” AC powered and low or Install or replace 9V 15 seconds every 15 seconds missing battery battery. Refer to Page 14 Error / service alarm Red LED flashes every 30 seconds One short “chirp” every 30 seconds Unit malfunction Call Kidde Customer Service Error Red LED constantly on Constant alarm Very low battery or unit Replace 9V battery. If malfunction. Unit will condition continues, not respond to CO call Kidde Customer Service Normal Test/Reset function Red LED flashes with beeps. Green and amber LED’s on 4 quick beeps, 5 seconds silence, repeated once Normal operation when Test/Reset button is pressed CO not detected. Alarm for test purposes only WARNING: IF AT ANY TIME YOU TEST THE ALARM AND IT DOES NOT PERFORM AS DISCRIBED, HAVE IT REPLACED IMMEDIATELY. NOTE: REFERENCE TO BATTERY BACKUP OPERATION IS ONLY APPLICABLE TO UNITS THAT ARE EQUIPPED WITH BATTERY BACKUP OPTION. Testing To test the alarm, press the Test/Reset button. operating properly, by 5 seconds of silence LED will flash along with illuminate. Within several seconds the unit will to monitor for carbon monoxide. If interconnected to Kidde smoke pressing the Test/Reset button on the CO alarm will have no effect on the smoke alarms. The smoke alarms will not be tested and will not alarm. However, when pressing the Test button on an interconnected smoke alarm, the CO alarm will emit a Smoke/Fire audible and visual alarm pattern of 3 long beeps, 1 second of silence, repeated. Note: You do not need to press the Test button to take a CO reading. Battery THIS CO ALARM OPERATED. FOR ALARMS EQUIPPED BACK-UP, THE 9 VOLT BATTERY IS TO SUPPLY SHORT TERM BACKUP DURING POWER When replacing the battery, approved brands: Duracell MN1604 or MX1604 Energizer 522 Gold Peak 1604A These batteries can be purchased where you alarm or at a local hardware store. Use of a different battery may have a detrimental effect on the alarm operation. The 9 volt battery is not rechargeable. If the 9 volt battery is missing, disconnected, or if the battery’s power is low, red LED flash will occur once every 15 seconds, accompanied by an audible beep. If this happens, the battery must be replaced. IMPORTANT: Constant exposures to high or low humidity may reduce battery life. A good safety measure is to replace the battery at least once a year, or at the same time as you change your clocks for daylight saving time. Battery Alarm Removal If tamper resist feature resist feature description instructions. Remove the alarm from the mounting plate alarm in the direction of the “OFF” To disconnect the AC Quick-Connector squeeze the locking arms on the sides while pulling the away from the bottom of the alarm (see Figure 2). FOR ALARMS EQUIPPED WITH 9 VOLT BATTERY BACKUP After the alarm has been removed, you can open the battery door and replace the battery. Battery installation instructions are provided on the inside of the battery When installing the battery, orient the battery as shown unit label. Press the battery reminder tab down into the battery compartment and install the battery (see Figure 4). FIGURE 4 BATTERY REPLACEMENT CAUTION! If the battery reminder t...

Otros modelos de este manual:
Detector de incendios - KN-COB-IC (233.79 kb)
Detector de incendios - KN-COB-IC (233.79 kb)
Detector de incendios - P/N 900-0120 (233.79 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría