Manual de usuario Southbend, modelo HEAVY DUTY COUNTERLINE HDG-48

Fabricar: Southbend
Tamaño del archivo: 533.21 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


It indicates the type of gas the appliance is equipped to burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate. This appliance should be connected ONLY to the type of gas for which it is equipped. If the appliance is being installed at over 2,000 feet altitude and that information was not specified when ordered, contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure to install with proper orifice sizing will result in poor performance and may void the warranty. These models are design-certified for operation on natural or propane gases. For natural gas, the convertible regulator shipped with the appliance is set to deliver a 4" W.C. pressure to the manifold. For propane gas, it is set to deliver 10" W.C. An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure pressure. Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the appliance. Use pipe joint compound that is suitable for use with LP gas on all threaded connections. ! CAUTION ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE APPLIANCE HAS BEEN PUT INTO OPERATION. TEST PRESSURE SHOULD NOT EXCEED 14" W.C. To connect the gas supply, do the following: 1. Check that the gas supply to the piping that will be connected to the appliance is shut off. 2. Check that the manual shut-off valve inside the front panel door of the appliance is closed (60" and 72" models have two shut-off valves). 3. Check that all control knobs on the appliance are turned “OFF.” 4. Attach the pressure regulator shipped with the appliance to the 3/4" NPT gas inlet connector located on the rear of the appliance (see Figure 4 below). Be sure that the regulator is connected so that the gas flow is in the same direction as the arrow on the bottom of the regulator. 5. Connect the vent line from the pressure regulator to the outdoors in accordance with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2, as applicable. 6. Connect the gas inlet of the pressure regulator to the building’s supply system. No segment of the gas supply connection to the appliance should be smaller than 3/4" NPT. Standard pipe fittings are required. 7. Turn on gas supply. 8. Check for leaks using soapy water. Figure 4 Vent tube included on griddlesbuilt afterJune 19, 2006. Step 5: Final Positioning, Clearance Check, and Ventilation Chec...

Otros modelos de este manual:
Otros aparatos de cocina - HEAVY DUTY COUNTERLINE HDG-24 (533.21 kb)
Otros aparatos de cocina - HEAVY DUTY COUNTERLINE HDG-24-M (533.21 kb)
Otros aparatos de cocina - HEAVY DUTY COUNTERLINE HDG-36 (533.21 kb)
Otros aparatos de cocina - HEAVY DUTY COUNTERLINE HDG-36-M (533.21 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría