|
Resumen del manual
6. Do not use a unit with a damaged power cord. The power cord should not be altered, jerked, bundled, weighed down, pinched, or tangled. Such actions could result in electric shock or fire. To unplug the unit, be sure to pull the plug, not the cord, and do not jerk the cord. 7. To reduce the risk of electric shock, do not touch the plug or control switch with damp hands. 8. The GREEN ground wire in the factory-installed power cord is connected to a screw on the rear panel where the cord enters the unit. If it becomes necessary to remove or replace the power cord, be sure to connect the power cord's ground wire to this screw upon reattachment. • Usually an electrical permit and services of a licensed electrician are required. • The maximum allowable voltage variation is ±10 percent of the nameplate rating. • For optional drain pump installation, refer to the instruction manual included with the pump. 20 21 F. Water Supply and Drain Connections WARNING 1. Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations. 2. Normal operating water temperature should be within 45°F to 95°F (7°C to 35°C). Operation of the icemaker, for extended periods, outside of this normal temperature range may affect icemaker performance. 3. To prevent damage to equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached. • A plumbing permit and services of a licensed plumber may be required in some areas. • External filters, strainers, or softeners may be required depending on water quality. Contact your local Perlick distributor for recommendations. • Water supply inlet is 1/2" female pipe thread (FPT). • A water supply line shut-off valve and drain valve should be installed. A minimum of 3/8" OD copper tubing is recommended for the water supply line. • Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required. • Drain outlet is 1/2" FPT. • Drain line should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipe from the icemaker and the floor drain. • For gravity drain installation, drain must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get good flow. A vented tee connection is also required for proper flow. • For optional drain pump installation, refer to the instruction manual included with the pump. Fig. 23 Water Supply Line Shut-Off Valve Water Supply Line Drain Valve Water Supply Inlet 1/2" FPT Drain Outlet 1/2" FPT Piping to approved drain. Leave a 2.inch (5-cm) vertical air gap between the end of the pipe and the drain. 2-inch (5-cm) air gap Floor Drain Vented Tee Connection G. Final Checklist WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the storage bin. 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within 45°F to 100°F (7°C to 38°C) and the water temperature within 45°F to 95°F (7°C to 35°C) all year around? 3) Have the shipping carton, tape, and packing material been removed from the icemaker? 4) Have all electrical and water connections been made? Do electrical and water connections meet all national, state, and local code and regulation requirements? 5) Has the power supply voltage been checked or tested against the nameplate rating? Is the power supply a properly grounded, independent wall outlet? 6) Are the water supply line shut-off valve and drain valve installed? Has the water supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG? 7) Are all components, fasteners, and thumbscrews securely in place? 8) Has the end user been given this instruction manual, and instructed on how to operate the icemaker and the importance of the recommended periodic maintenance? 9) Has the end user been given the name and telephone number of an authorized service agent? 10) Has the product registration card been filled out and forwarded to the factory for warranty registration? 22 H. Startup WARNING 1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. 2. If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor. 3. At startup, confirm that all internal and external connections are free of leaks. 1) Open the water supply line shut-off valve. 2) Make sure the control switch is in the "OFF" position. Plug the unit into the electrical outlet. If you have to slide the unit back for a built-in installation, make sure you do not damage or pinch the water supply, drain connections, or power cord. 3) If required by sanitation code in your a...
Otros modelos de este manual:Otros aparatos de cocina - SELF CONTAINED H50IMS-ADL (2.26 mb)
Otros aparatos de cocina - SELF CONTAINED H50IMS-L (2.26 mb)
Otros aparatos de cocina - SELF CONTAINED H50IMS-ADR (2.26 mb)
Otros aparatos de cocina - SELF CONTAINED H50IMW (2.26 mb)