|
Resumen del manual
Make sure that none have fallen into the storage bin. 2. The storage bin is for ice use only. Do not store anything else in the storage bin. 3. Keep the area around the icemaker clean. Dirt, dust, or insects in the unit could cause electrical damage to the equipment or harm to individuals. A. Cleaning and Sanitizing Instructions Perlick recommends cleaning and sanitizing this unit at least once a year. More frequent cleaning and sanitizing, however, may be required in some existing water conditions. WARNING 1. To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners. 2. Carefully follow any instructions provided with the bottles of cleaning and sanitizing solution. 3. Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing solutions from coming into contact with skin or eyes. 4. After cleaning and sanitizing, be careful not to leave any cleaning or sanitizing solution in the icemaker. 1. Cleaning Solution IMPORTANT For safety and maximum effectiveness, use the solution immediately after dilution. Dilute 4 fl. oz. (118 ml or 8 tbs) of recommended cleaner "Liquid Ice Machine Cleaner" Part No. 4207-32 (Nu-Calgon) with 1 gallon (3.8 l) of warm water. This is a minimum amount. Make more solution if necessary. It is recommended that cleaning be performed by a qualified service technician. 2. Cleaning Procedure 1) Remove all ice from the evaporator and the storage bin. Note: To remove cubes on the evaporator, move the control switch to the "OFF" position and then move it back to the "ICE" position after 3 minutes. The harvest cycle starts and the cubes will be removed from the evaporator. 2) Move the control switch to the "OFF" position. 24 3) Inside the storage bin, disconnect the suction tube by squeezing the tabs and pulling the tube clear. See Fig. 26. Allow the water tank to drain. 4) Reconnect the suction tube as illustrated. See Fig. 27. Make sure the tabs lock into place; a loose fitting may cause a water leak. Tabs Water Tank Tabs Suction Tube Suction Tube Drain Fig. 26 Fig. 27 5) Slowly pour the cleaning solution into the water tank. 6) Move the control switch to the "WASH" position. 7) Allow the cleaning solution to circulate for 30 minutes, then move the control switch to the "OFF" position. 8) Disconnect the suction tube. Allow the water tank to drain, then reconnect the suction tube. 9) Move the control switch to the "ICE" position and allow the icemaker to operate for 2 minutes. This allows the water tank to fill with water. 10) Move the control switch to the "WASH" position. 11) Allow the water to circulate for 5 minutes, then move the control switch to the "OFF" position. 12) Disconnect the suction tube. Allow the water tank to drain, then reconnect the suction tube. 13) Repeat steps 9 through 12 three more times to rinse thoroughly. 25 26 3. Sanitizing Solution IMPORTANT For safety and maximum effectiveness, use the solution immediately after dilution. Dilute 0.5 fl. oz. (14.8 ml or 1 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 1 gallon (3.8 l) of warm water. This is a minimum amount. Make more solution if necessary. Using a chlorine test strip or other method, confirm that you have a concentration of about 200 ppm. 4. Sanitizing Procedure 1) Make sure the control switch is in the "OFF" position and the storage bin is empty. 2) Remove the slope from the storage bin by carefully bending it in the center and releasing it from the 2 slope shafts. See Fig. 28. 3) Remove each separator by lifting it to the horizontal position and pushing it hard inward. See Fig. 29. 4) Disconnect the suction tube. Allow the water tank to drain. 5) Spread out the tabs to unlock the water tank, then slide it out. See Fig. 30. 6) Lift off the ice chute from the front frame pipe and then from the rear frame pipe. See Fig. 31. Separator Ice Chute Front Frame Pipe Tab Tab Slope Fig. 28 Fig. 29 Fig. 30 Fig. 31 Rear Frame Pipe Slope Shafts Water Tank 7) Disconnect the discharge tube from the spray assembly, then slide out the spray assembly. See Fig. 32. 8) Remove the two caps. See Fig. 33. Discharge Tube Caps Spray Assembly Fig. 32 Fig. 33 9) Soak all of the removed parts and the scoop in the sanitizing solution for 10 minutes. If the spray assembly nozzles are clogged, clean them with a wire or a suitable brush. 10) Rinse the parts thoroughly with clean water. 11) Refit the 2 caps in their correct positions. Make sure the reducing pipe is in place in the center. See Fig. 34. 12) Slide in the spray assembly along the rails on the left and right brackets. See Fig. 35. Connect the discharge tube securely to the spray assembly; a loose fitting may cause a water leak. Reducing Pipe Left Bracket Right Bracket Rail Rail Caps Discharge Tube Fig. 34 Fig. 35 13) Position and lock the ice chute onto the front and rear frame pipes by pushing the ice chute down until it clicks onto both frame pipes. See Fig. 36. 14) Slide in the water tank along the ...
Otros modelos de este manual:Otros aparatos de cocina - SELF CONTAINED H50IMS-ADL (2.26 mb)
Otros aparatos de cocina - SELF CONTAINED H50IMS-L (2.26 mb)
Otros aparatos de cocina - SELF CONTAINED H50IMS-ADR (2.26 mb)
Otros aparatos de cocina - SELF CONTAINED H50IMS-R (2.26 mb)