Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Dynasty Spas, modelo VS500

Fabricar: Dynasty Spas
Tamaño del archivo: 405.83 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The default filter time is 2 hours. To program, press “Temp” or “Set,” then “Jets.” Press “Temp” or “Set” to adjust. Press “Jets” to exit programming. At the beginning of each filter cycle the blower purges for 30 seconds; the pump purges for 5 minutes. The only effect filter duration has is: 1) During the filter, the circ pump never turns off, and 2) In Economy and Sleep Modes, heating only occurs during the filter cycle. Freeze Protection If the temperature sensors detect a drop to below 44°F/6.7°C within the heater, the pump and blower will automatically activate to provide freeze protection. The equipment stays on until 4 minutes after the sensors detect that the spa temperature has risen to 45°F/7.2°C or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Aux freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a 4-minute delay in turnoff. See your dealer for details. (over) Diagnostic Messages Message Action Required Meaning The control panel will be disabled until power returns. Spa settings will be preserved until next power up. After the circ pump has been running for 2 minutes, the temperature will be displayed. DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. Once the heater has cooled, reset by pushing any button. If spa does not reset, shut off the power to the spa and call your dealer or service organization. DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. At 107°F/42°C, the spa should automatically reset. If spa does not reset, shut off the power to the spa and call your dealer or service organization. No action required. The pump and blower will automatically activate regardless of spa status. If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools.) If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools.) If the problem persists, contact your dealer or service organization. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. If problem persists, contact your dealer or service organization. Follow action required for “” message. Heating capability of the spa will not reset automatically; you may press any button to reset. Check water level in spa. Refill if necessary. If water level is okay, make sure the pumps have been primed. Press any button to reset, or this message will automatically reset within 15 minutes. If problem persists, contact your dealer or service organization. Follow action required for “” message. Spa will not automatically reset. Press any button to reset. No message on display. Power has been cut off to the spa. Temperature unknown. “Overhea...

Otros modelos de este manual:
Otros accesorios para la casa - GS500 (405.83 kb)
Otros accesorios para la casa - VS501 (405.83 kb)
Otros accesorios para la casa - GS501 (405.83 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría