Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Invacare, modelo 3600XL

Fabricar: Invacare
Tamaño del archivo: 1.01 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


NOTE: For this procedure, refer to FIGURE 3.3. Flow Water Thermometer .measures the Flow Water Thermometer temperature of water coming from the tub fill spout or shower/massage wand. Water Temperature Control Valve .sets and maintains constant temperature for all incoming water. Water Temperature Valve FIGURE 3.3 Water Temperature Setting Part No 1118387 25 Side Entry Whirlpool Tub SECTION 3—OPERATING INSTRUCTIONS Operating Shower/Massage Wand NOTE: For this procedure, refer to FIGURE 3.4. NOTE: STEPS 1 .3 are to be performed while holding the shower/massage wand over the tub. 1. Turn shower/massage wand on to desired flow by rotating shower On/Off valve (Detail “A”). 2. Adjust water temperature using the water temperature valve while watching the flow water thermometer (Detail “B”). 3. Adjust shower spray by rotating shower wand head (Detail “C”). NOTE: Refer to following chart for shower head adjustment settings. Stream Shower Spray Mixture of Spray and Pulse Massage Pulse Massage 4. Turn shower On/Off valve to off position when finished. Water Temperature Valve Flow Water Thermometer Shower On/Off Valve Shower/Massage Wand Head DETAIL “C” DETAIL “B” DETAIL “A” FIGURE 3.4 Operating Shower/Massage Wand Filling Tub NOTE: For this procedure, refer to FIGURE 3.5 on page 27. 1. Close the drain (Detail “A”). 2. Turn tub fill On/Off valve to on position by rotating valve (Detail “B”). 3. Adjust water temperature using the water temperature valve while watching flow water thermometer (Detail “C”). CAUTION Before starting hydromassage, water level MUST be completely above whirlpool jets otherwise severe damage to the motor/pump will result. 4. Turn tub fill On/Off valve to off position when water reaches desired level (Detail “B”). Side Entry Whirlpool Tub 26 Part No 1118387 SECTION 3—OPERATING INSTRUCTIONS DETAIL “A” DETAIL “C” Models 3600 and 3600XL Model 3650 DETAIL “B” Flow Water Thermometer Water Tub Fill On/Off Valve Temperature Valve Drain Drain FIGURE 3.5 Filling Tub Hydromassage CAUTION Before starting hydromassage, water level MUST be completely above whirlpool jets otherwise severe damage to the motor/pump will result. NOTE: For this procedure, refer to FIGURE 3.6 on page 27. 1. Close the aerator by rotating the aerator valve two turns clockwise. 2. Open the whirlpool inlet by pushing the inlet plug in. 3. Open all whirlpool jets by pulling the center of the whirlpool jet out or rotating the center counterclockwise (Detail “A”). 4. Fill the tub. Refer to Filling Tub on page 26. 5. After water level covers whirlpool jets and after bathing the resident, add Invacare Defoamer to bath water. Refer to Defoamer bottle for directions. 6. Push whirlpool On/Off (Detail “B”) button to start whirlpool jets. 7. Adjust the whirlpool aerator for desired water agitation by rotating the whirlpool aerator (Detail “C”). 8. After use, push whirlpool On/Off button (Detail “B”) to stop whirlpool jets. 9. Drain tub. DETAIL “A” DETAIL “B” DETAIL “C” Whirlpool Aerator Whirlpool On/Off Button Whirlpool Jet Push In To Turn Clockwise Close to Close Plug FIGURE 3.6 Hydromassage Part No 1118387 27 Side Entry Whirlpool Tub SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING SECTION 4—SAFETY INSPECTION/ TROUBLESHOOTING NOTE: Every six months or as necessary have a qualified technician perform a thorough inspection and servicing. Routine maintenance will extend the life and efficiency of your tub. Safety Inspection Checklists Initially . Ensure that the maximum water supply temperature does not exceed 115° F. . Ensure that the maximum water pressure does not exceed 65 PSI. . Verify the water flow temperature with a separate thermometer. . Visually inspect for cracks in the tub surface. . Ensure that the door handle locks the door closed. . Ensure that the safety pin properly engages the door. . Check that all labels are present and legible. Replace if necessary. Before Each Use . Disinfect the tub. . Ensure that the maximum water supply temperature does not exceed 115° F. . Ensure that the maximum water pressure does not exceed 65 PSI. . Visually inspect for cracks in the tub surface. . Ensure that the door handle locks the door closed. . Ensure that the safety pin properly engages the door. Every 80-150 Baths . Perform the heavy duty cleaning procedure on the tub. Refer to Heavy Duty Cleaning Procedure on page 30. Every Six Months . Verify the water flow temperature with a separate thermometer. . Check that all labels are present and legible. Replace if necessary. . Clean RADA valve to remove lime deposits. Side Entry Whirlpool Tub 28 Part No 1118387 SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING Cleaning Cleaning the Door Seal Gasket The rubber door seal gasket should remain clean and free of debris. Use a working solution of a commercially available heavy duty cleaner such as Invacare.s Heavy Duty Cleaner and a sponge to thoroughly wipe the entire length of the rubber seal, making sure to remove all traces of soap scum and other debris. Remov...

Otros modelos de este manual:
Otros accesorios para la casa - 3600 (1.01 mb)
Otros accesorios para la casa - 3650 (1.01 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría