Iniciar sesión:
Votos - 5, Puntuación media: 4 ( )

Manual de usuario Omega Vehicle Security, modelo DP25-TH

Fabricar: Omega Vehicle Security
Tamaño del archivo: 283.74 kb
Nombre del archivo: MQS1848.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Apply power to the unit. The unit initializes, 1. Press MENU until the display and begin operation. Information is provided on how to: the rear of the unit. flashing OTHERMISTORO. Then the temperature shows OINPTO: • Connect ac power should appear. 2. Connect sensors, referring to the appropriate • Connect sensor input diagram below and tighten down lockdown 2. Verify that a temperature is displayed. If not: screws. • Set basic options for operation . Remove ac power 3. Tug gently on the wires to verify the connections. 2. Press © /MIN to show current input For complete information on all setup options, see the . Verify the TB1 power connections type: Operator Os Manual. 4. Replace the panel at the back of the unit. • Check your power source Before You Begin 1 3 . Apply power again 2 In addition to the controller and the related parts, you -S - R 3. Press ¶ /MAX to select the setting. +S Configure the Unit will need the following items to set up your unit: Choices are: 4004, 4005, 4006, • ac power 4007, 4008, 4017, 4018 and 700. To configure the unit, use the buttons on the controller O s • Sensor front panel. 1 . U8 O flat blade screwdriver 45,00 + 0,61/-0,00 (1.772 + .024/..000) 92,00 + 0,81/.0,00 (3.622 + .032/..000) 1,5R(.06) 4 PLCS To: Take This Action 2-Wire Input (400 Series) 4. Press MENU to store the value. PANEL THICKNESS 6,4 (.25) MAX 5. Press RESET twice to display the current 0,8 (.03) MIN temperature. Mount the Meter Display the Press the MENU button. Configuration The first function on the 1. Cut a panel opening Menu. menu, OINPTO, displays. using the dimensions 1 shown to the right. Select the 1. Press MENU until the 23 +S -S-R submenu function you want is shown. 2. Position the unit in the NOTE: Dimensions in Millimeters (Inches) function. 2. Press © /MIN. opening, making sure the front bezel is flush with the panel. To Change the Decimal Point: Select a value 1. Press ¶ /MAX. to display for that submenu the option you want. 1. Press MENU until the display Connect ac Power function. 2. Press MENU to select it. shows ODEC.PO: 3-Wire Input (700 Series) OSTRDO quickly flashes, Warning: Do not connect ac power to your meter indicating that the selection until you have completed all input and output has been stored in memory. connections. Failure to do so may result in injury! Then the next menu function Hook up Alarm 1 (Setpoint) (refer to TB1 Main displays. 1. Remove the panel at the back of the unit. 2. Press © /MIN to show the current ac Power Connection Drawing) decimal point location: 2. Locate the TB1 connector. Go back to the Press RESET once. 1. Connect a jumper from ac Line (Terminal 7) to previous menu 3. Insert the correct wire in each terminal as shown Relay 1 Common (Terminal 3). function. in the following figure and tighten the lockdown screws. Tug gently on the wires to verify 2. Connect Relay 1 Normally Open (Terminal 1) to Exit the . Press RESET twice. The connections. External Alarm ac Line. Configuration unit reinitializes (displays 3. Press ¶ /MAX to select the setting. VERSION #1 VERSION #2 3. Connect External Alarm to ac Neutral (Terminal 8). Menu. ORSTO, then OTHERMISTORO). Choices are: OFFF.FO, OFFFF.O or When the temperature OFF.FFO. displays, the meter is back in Hook up Alarm 2 (Setpoint) (refer Run Mode. 4. Press MENU to store the value. ac Power Connection 5. Press RESET twice to display the current . Optionally, you can press temperature. 1. Connect a jumper from 7) to MENU to move through all Relay 2 Common 6). the menu functions GROUND NEUTRAL meter reinitializes. 2. Connect Relay 4) to LINE AC POWER External Alarm ac Line. FUSE Main Power Connections 3. Connect Alarm to ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX TB1 10 11 12 EARTH TB1 TB3 TB2 8 97 654321 321 10 11 128 97 654321 321 ¶ © SETPTS /MIN MENU RESET/MAX ¶ © SETPTS /MIN MENU RESET/MAX WARRANTY/DISCLAIMER OMEGA Engineering, Inc. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA Os customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA Os Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. Omega’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. T...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría