Iniciar sesión:
Votos - 3, Puntuación media: 3.3 ( )

Manual de usuario Kawasaki, modelo 840169

Fabricar: Kawasaki
Tamaño del archivo: 477.14 kb
Nombre del archivo: 62a8840b-d5ef-42a1-aed5-2279af18cbdb.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Following this preventative step reduces the risk of the saw coming on accidentally and the risk of damage to the workpiece and injury to the operator. Never hold the tool near your face. Accessories like wire brushes or grinding wheels may come apart during use. Be careful not to cover the air vents with your hand. This will cause the motor to overheat. 11 S M H Slow 8,000-12,000 RPM Medium 20,000-25,000 RPM High 29,000-33,000 RPM SPEED CONTROL DIAL Rotary Tool Speed Settings If you must use an extension cord, be sure that the gauge is large enough to carry the amount of current necessary for your power tool. If not, your tool may experience a loss of power, excessive voltage drop or overheating. The smaller the gauge number, the heavier the cord (see table below). RECOMMENDED SIZES OF EXTENSION CORDS 120 VOLT AC 60 HZ TOOLS TOOL CURRENT RATING CONDUCTOR SIZE IN A.W.G AMPERE 10FT. 25FT. 50FT. 100FT. 3-6 18 18 18 18 6-8 18 18 18 16 8-10 18 18 18 14 10-12 16 16 14 14 12-16 14 12 12 - 16-20 12 12 12 - INSERTING/REMOVING ACCESSORIES Always unplug rotary tool before changing accessories, changing collets or servicing. The tool could start unexpectedly, causing serious injury. To loosen the collet nut: 1. Press the shaft lock button. Rotate the shaft manually until the lock engages and prevents further rotation. DO NOT ATTEMPT TO ENGAGE THE SHAFT LOCK WHILE THE TOOL IS RUNNING. 2. If the collet nut has a hexagonal shape, use a wrench to loosen the collet nut by turning in the direction of the arrow labeled L in the illustration. The collet nut must be loose in order to insert or remove accessories. 3. Remove the old accessory (if any) and install the new accessory, being sure to push it as far as possible into the collet. 4. Tighten the collet nut by hand until snug. 5. Finish tightening the collet by turning the wrench in the direction of the arrow labeled T in the illustration. Do not overtighten. 14 MAINTENANCE AND CLEANING Always UNPLUG the Rotary Tool from the power source before inspecting, performing any maintenance or cleaning. This Rotary Tool is lubricated before it leaves the factory. This lubrication should last for the life of the tool. No further lubrication is required. Use only mild soap and a damp cloth to clean the tool. Never let any liquid get inside the casing. Never immerse any part of the tool in a liquid. Always keep the ventilation openings clear. Brushes will wear with use and should be inspected periodically by qualified personnel. Regularly clean the ventilation slots in your tool using only a soft brush or dry cloth. Never open the Rotary Tool case. Do not attempt to repair the Rotary Tool yourself. Opening the case will void your warranty. ACCESSORIES Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one tool may become hazardous when used on another tool. Always attach grounded (3-prong) extension cords to grounded (3-hole) outlets. This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. 13 CONNECTING FLEXIBLE SHAFT TO TOOL (MODELS 840168 AND 840169) Never bend the flexible shaft with a radius of less than 6” when operating. Please store the flexible shaft in the designated compartment of the tool box when not in use. Not for use with router bits. Use with router bits with cause kickback. 1. Remove spindle nut and collet nut from the tool by turning them counterclockwise. 2. Remove the collet from motor shaft. 3. Insert flexible shaft inner cable into the motor shaft until the stopper touches the motor shaft. 4. Thread flexible shaft collet nut onto the motor shaft by turning it clockwise. Tighten with collet wrench. 5. Thread flexible shaft nut onto the tool housing by turning it clockwise. Only tighten flexible shaft nut finger tight. DO NOT use pliers or wrench. 16 COLLET SIZES Your rotary tool kit may have multiple collets to accommodate different accessories with varying shank sizes. To change a collet: 1. Loosen the collet nut as described above, then remove the collet nut. 2. Remove the old collet. 3. Insert the loose collet. 4. Tighten the collet nut as described above. Each collet has a series of rings on its shank that identify its size. • 1/32” – one (1) ring • 1/16” – two (2) rings • 3/32” – three (3) rings • 1/8” – no rings BALANCING For best results, be sure to balance each accessory in the collet. Your tool’s high RPM makes imbalances easily detectable as a wobble while the tool is running. To balance an accessory: 1. Stop the tool. 2. Loosen the collet nut. 3. Rotate the accessory 1/4 turn. 4. Tighten the collet. 5. Run the tool. 6. Continue adjusting as neede...

Otros modelos de este manual:
Otras herramientas - 840168 (477.14 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría