Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario HP, modelo HP 3PAR Operating System Software

Fabricar: HP
Tamaño del archivo: 92.17 kb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere


Otros manuales para este modelo:

Resumen del manual


These release notes describe the modifications and known issues for Patch 01. This is a mandatory
patch and is intended to be applied to HP 3PAR OS 3.1.2.278 (GA) only. Only an authorized HP
Service provider should perform this maintenance procedure.
1.1 Supported platforms
The HP 3PAR Configuration Matrix for HP 3PAR OS 3.1.2 contains information about supported
hardware and software platforms. For a list of supported versions of each operating system, see the
Single Point of Connectivity Knowledge (SPOCK) website http://www.hp.com/storage/spock.
1.2 Verifying the patch installation
The installation of Patch 01 can be verified from an Interactive CLI session. Issue the CLI command
showversion -a -b to verify that Patch 01 is listed.
showversion -a -b
Release version 3.1.2.278
Patches: P01
Component Name Version
CLI Server 3.1.2.282 (P01)
CLI Client 3.1.2.278
System Manager 3.1.2.282 (P01)
Kernel 3.1.2.278
TPD Kernel Code 3.1.2.278
TPD Kernel Patch 3.1.2.282 (P01)
1.3 Components
Component
Version
HP 3PAR OS
3.1.2.278
NOTE:
Applying this patch to the HP 3PAR OS may cause a restart of the affected OS components.
With these restarts, expected behaviors such as events and alerts may generate. The system will
continue to serve data but existing CLI or MC (Management Console) sessions may be interrupted.
NOTE:
After installation of this patch, the patch description indicates Addressed a powerfail
issue on the 3PAR StoreServ 7000 series. This issue is actually resolved for all HP 3PAR
platforms.
1.4 Modifications to the HP 3PAR OS
The following items have been addressed in this release.
Bug ID
Item
Description
81544
CLI commands are not
The CLI commands showcage and showinventory are not displaying
displaying the correct
correct values for some manufacturing information. This was resolved by
EEPROM values
correcting the reading of the VPD EEPROM information and now displays
the correct output.
81657
A data inconsistency issue
A data inconsistency issue arises when a disk media failure is encountered
arises when a disk media
during a RAID-1 data reconstruction while moving a chunklet. This issue is
failure is encountered during
resolved by correctly updating the Logical Disk (LD) offset of each split
1.1 Supported platforms
3


...

Otros modelos de este manual:
datos de dispositivos de procesamiento - HP 3PAR F200 9.6TB (16) 600Gb 15K HDD Field Starter Kit (92.17 kb)
datos de dispositivos de procesamiento - HP 3PAR F200 Configuration Base (92.17 kb)
datos de dispositivos de procesamiento - HP 3PAR F200 Field Starter Kit (92.17 kb)
datos de dispositivos de procesamiento - HP 3PAR F400 9.6TB (16) 600Gb 15K HDD Field Starter Kit (92.17 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría