Manual de usuario 3M, modelo 2475

Fabricar: 3M
Tamaño del archivo: 425.7 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Island mode is used where a single speaker serves both sides of a dispenser. Procedure 1: Press and hold the HOLD key while applying power to any Selector. OR Procedure 2: Reset or remove power from any Station in one of the following ways. a. Unplug the RS485 cable. b. Press and hold the STD BY key while entering the numeric code 911. Resetting the Station To reset only the station selector: Selector 1. Press and hold the STD BY key. (Reset) 2. Enter the numeric code: 911. Resetting the System To reset only the entire system: (Reset) 1. Press and hold the STD BY key. 2. Enter the numeric code: 8642. Turning off power, and then turning it back on. Commonly referred to as a “Cold Boot”. Restarting the micro controller firmware. Commonly referred to as the “Warm Boot.” Over writes the EEPROM memory with factory default values. This process also selects “Pump” or “Island” mode of operation change the EEPROM memory from factory default values to user preferences 10 Performance Series Programming the System Programming the System ! Important If you have not selected the mode of operation (Pump or Island) do so now! See System Mode Selection. Programming State To program the Performance Series Intercom System, it is necessary to put the system in the programming state. From this state, the entire system is configured and all memorized parameters are adjusted. To enter the programming state, simultaneously: Press and hold the STD BY key. Enter the numeric code: 97531. The display shows: 1234567890MENUTALK SP-389C Figure 11. D-2400 Keypad 01:Selector ID # {01} The Parameter #, Parameter Name/Value, and Parameter Value fields are as shown below. Parameter Parameter # Name/Value v v 01:Selector ID # {01}< Parameter Value The “_ “ indicates cursor position. To move the cursor from one field to another, use the Left Arrow and Right Arrow keys. To input data at the cursor position, do one of the following: • Use the Up Arrow and Down Arrow keys to scroll to desired value. • Use the 1, 2, 3, 4, 5, 6, 7, 8, 9, 0/Menu keys. The STD BY key clears a field to a default value (space for text or the default value). The HOLD key shifts case for text data. The ALL CALL key exits from the programming state and enters the Off Line mode. ! Important All Station Selectors ship from the factory with a default ID number of 15. It is important to connect and power up each new Station Selector, ONE STATION SELECTOR AT A TIME, when installing a new system. Doing this allows you to change the ID number to a lower value (start at 1) and avoid the erratic behavior caused by multiple Station Selectors sharing the same ID number. 11 Programming the System Performance Series Error Message The system will display one error message: No Communication. This message occurs when there is no communications between the Station ! E R R O R ! Selector and Communications Controller. To correct this: NO COMMUNICATION Parameter Selection 01:Selector ID # {01} 02:Controller {D2400 1-Chnl} 03:Max Stations {24} 04:Silence Calls {Off} 05:Alert Volume {08} 06:Alert Type {Chime} • Be sure Communications Controller is powered on. • Be sure pins 2 and 3 of J3 on the Communications Controller are connected to pins 2 and 3 of J8 (RS-485 connector) on the Station Selector. Polarity must be correct! • Call 3M Technical Service to confirm software compatibility between station selector and communication controller. Memorized parameters are given below. These parameters are stored in the EEPROM. The 16-character by 2-row LCD displays the parameters. A number (1 to 15 inclusive). Default = 15. This number must be unique relative to all other Station Selector ID numbers used in the system. Displays the model of the Communications Controller connected to the Station Selector. If no Communications Controller is connected {Undefined} will be displayed. A number (1 to 24 inclusive). Total number of Call Stations in the system. Default = What the Communications Controller senses. Stations are numbered starting with 1 up to this value. This value should be adjusted to equal the number of speakers connected to the Communications Controller, preventing an operator from accessing an unwired Call Station. If installing or removing additional I/O cards after the initial installation, you must re-program parameter03for each station selector connected to the system. A value (On, Off). Default = Off. Off = normal operation. On = Station Selector will only respond to page requests from other Station Selectors. It will not respond to Call Station requests. This is useful for a Station Selector placed in a manager’s office. The manager will not hear Call Station alerts. He will hear only page requests from employee’s Station Selectors. A number (1 to 15 inclusive). Default = 08. Adjusts the volume of the Station Selector alert tone (Chime or Beep). A value of 15 is the loudest setting. Beep or Chime. Default = Chime. 12 Performance Series Programming the System 07:VOX Enable {Off} 08:VOX S...

Otros modelos de este manual:
Teléfonos fijos - 2470 (425.7 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría