Resumen del manual


- 56041684 - BA 755, BA 855 - B-5 B-6 / ENGLISH KNOW YOUR MACHINE 16 Solution Drain Hose / Level Indicator 26 Squeegee Adjustment Knob 17 Squeegee Raise / Lower Lever 27 Recovery Tank Drain Hose 18 Battery Pack Connector (non onboard charger models only) 28 Debris Hopper (Cylindrical Models Only) 19 Recovery Hose 29 Idler Assembly (Cylindrical Models Only) 20 Wheel Drive Circuit Breaker 30 Solution Manifold (Cylindrical Models Only) 21 Control Circuit Circuit Breaker 31 Extended Scrub Filter (Optional) 22 Squeegee Blade Tension Strap 32 Vacuum Shut Off Switch 23 Squeegee Blade Latch 33 Control Panel 24 Squeegee Blade Alignment Pins 34 Drive Paddle 25 Squeegee Mount Thumb Nut 35 Speed Limit Control Knob B-6 - FORM NO. - 56041684 - BA 755, BA 855 ENGLISH / B-7 CONTROL PANEL - EDS A Key Switch (Main Power) B Solution Switch C Vacuum Switch D Display Panel D1 Solution Flow Indicator D2 Fault Indicator D3 Hour Meter D4 EDS Indicator D5 Battery Indicator D6 Scrub Pressure Indicator D7 Recovery Tank FULL Indicator D8 Battery Low Indicator E Wand Switch (Dealer Installed Option) F Detergent System (EDS models only) G Extended Scrub System (Dealer Installed Option) H Scrub OFF I Scrub ON A A UT j ~\ 1 1 in cm —h— ! Regular Heavy Extreme Regular Heavy Extreme ¡ i Scrub Scrub Scrub Scrub Scrub Scrub i (press once) (press twice) (hold 5 sec.) 1 FORM NO. - 56041684 - BA 755, BA 855 - B-7 B-8 / ENGLISH CONTROL PANEL - STANDARD A Key Switch (Main Power) B Solution Switch C Vacuum Switch D1 Solution Flow Indicator E Wand Switch (Dealer Installed Option) G Extended Scrub System (Dealer Installed Option) H Scrub OFF I Scrub ON J Display J1 Battery Indicator J2 Hour Meter / Scrub Pressure Indicator / Fault Code Display / Recovery Tank FULL Indicator B-8 - FORM NO. - 56041684 - BA 755, BA 855 ENGLISH / B-9 BATTERIES If your machine shipped with batteries installed do the following: • Check that the batteries are connected to the machine (14 or 18). • Turn ON the Key Switch (A) and check the Battery Indicator (D or J1). If the gauge is completely filled or the green light is ON, the batteries are ready for use. If the gauge is less than full or the green light is OFF, the batteries should be charged before use. See the “Charging The Batteries” section. • IMPORTANT!: IF YOUR MACHINE HAS AN ONBOARD BATTERY CHARGER REFER TO THE OEM PRODUCT MANUAL FOR INSTRUCTIONS REGARDING SETTING THE CHARGER FOR BATTERY TYPE. See TSBUS2007-979 for the latest battery charger algorithms. If your machine shipped without batteries installed do the following: • Consult your Authorized Nilfisk dealer for recommended batteries. • Install the batteries by following the instructions below. • DO NOT install three 12 volt batteries in your machine. This affects the stability of the machine. • IMPORTANT!: IF YOUR MACHINE HAS AN ONBOARD BATTERY CHARGER REFER TO THE OEM PRODUCT MANUAL FOR INSTRUCTIONS REGARDING SETTING THE CHARGER FOR BATTERY TYPE. See TSBUS2007-979 for the latest battery charger algorithms. M WARNING! Use extreme caution when working with batteries. Sulfuric acid in batteries can cause severe injury if allowed to contact the skin or eyes. Explosive hydrogen gas is vented from the batteries through openings in the battery caps. This gas can be ignited by any electrical arc, spark or flame. Do not install any lead-acid battery in a sealed container or enclosure. Hydrogen gas from overcharging must be allowed to escape. When Servicing Batteries... * Remove all jewelry * Do not smoke * Wear safety glasses, rubber gloves and a rubber apron * Work in a well-ventilated area * Do not allow tools to touch more than one battery terminal at a time FIGURE 1 * ALWAYS disconnect the negative (ground) cable first when replacing batteries to prevent sparks. * ALWAYS connect the negative cable last when installing batteries. M CAUTION! 305 AH @20 HR RATE (6) [Î3 MAX â 267KG/588LB Electrical components in this machine can be severely damaged if the batteries are not installed and connected properly. Nilfisk, a qualified electrician, or the battery manufacturer should install batteries. 1 Remove the batteries from their shipping crate and carefully inspect them for cracks or other damage. If damage is evident, contact the carrier that delivered them or the battery manufacturer to file a damage claim. 2 Turn the Master Key Switch (A) OFF and remove the key. 3 Tip the recovery tank to the side, locked position. Remove the battery cables from inside the battery compartment. 4 Your machine comes from the factory with enough battery cables to install six 6 volt batteries. Carefully lift the batteries into the battery compartment and arrange them exactly as shown in FIGURE 1. Secure the batteries as close to the back of the machine as possible. 5 Install the battery cables as shown. Position the cables so the battery caps can be easily removed for battery service. 6 Carefully tighten the ...

Otros modelos de este manual:
Aspiradoras - 56315043(755C) (4.84 mb)
Aspiradoras - 56315044(855) (4.84 mb)
Aspiradoras - 56315045(755 EDS) (4.84 mb)
Aspiradoras - 56315046(755C EDS) (4.84 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría