READ AND KEEP FOR REFERENCE. INSTRUCTIONS Model PRO 3500hc Electrostatic Air Spray Gun 65 kV, HIGH CONDUCTIVITY, MANUAL GUN 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure For use with electrically conductive, solvent based coatings, including metal flake paint Part No. 222625, Series B NOTE: Any modification of genuine Graco parts or replacement of parts with non-Graco parts will void agency approvals. PRO 3500hc Electrostatic High Conductivity Air Spray Gun Part No. 223451 Conversion Kit To
239786, Series A Standard Spray Gun Includes GG0 series tip of choice Part No. 241469, Series A Acid Catalyzed Fluid Spray Gun Includes GG0 series tip of choice Part No. 233670, Series A Sealant Streaming Gun 308813J Read warnings and instructions. See page 2 for Table of Contents. Read warnings and instructions. See page 2 for Table of Contents. Table of Contents Symbols Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation. . . . . . . . . . . .
Ponga a tierra el pulverizador, el objeto que recibe el chorro pulverizado, las cubetas de pintura y disolvente. Sostenga firmemente la pistola a un lado de la cubeta puesta a tierra cuando dispare dentro de ella. Use solamente mangueras para pintura conductora sin aire. No utilice nunca tricloretano-1,1,1, cloruro de metileno ni otros disolventes a base de hidrocarburos halogenos o fluidos que contengan dichos disolventes en un equipo a presion de aluminio. El uso de estas sustancias puede prov
Disengage gun trigger safety. 5. Hold gun against grounded metal flushing pail. Trigger gun and increase fluid pressure 1/2 turn. Flush 1 minute. 6. Inspect for leaks. Do not stop leaks with hand or a rag! If leaks occur, perform Pressure Relief Procedure, page 8. Tighten fittings. Perform Startup, steps 1 - 5. If no leaks, proceed to step 7. 7. Place pump in paint pail. 8. Trigger gun again into flushing pail until paint appears. Move gun to paint pail and trigger for 20 seconds. Set gun safety
P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1993, Graco Inc. is registered to I.S. EN ISO 9001 45:1 RATIO PREMIER CARBON STEEL Cart-Mounted Airless Package WITH DURA-FLO 1800 DISPLACEMENT PUMP 315 bar, 31.5 MPa (4500 psi) Maximum Working Pressure 7 bar, 0.7 MPa (100 psi) Maximum Air Inlet Pressure Part No. 222973, Series B With High Pressure Fluid Filter Part No. 238144, Series B With High Pressure Fluid Filter, hose and gun 308215L Model 238144 Shown 05915 Important Safety Instructions R
233889, Series A Heavy Duty RAC tip guard, 519 SwitchTip™ Part No. 234032, Series A Standard (nonreversing) Dripless™ tip guard, 519 flat tip 7250 psi (50 MPa, 500 bar) Maximum Working Pressure Read warnings and instructions. Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001 Contents Contents Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . 2 Warning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10. Leaking around throat packing nut which may indicate worn or damaged packings. 10. Replace packings; see pump manual. Also check piston valve seat for hardened paint or nicks and replace if necessary. Tighten packing nut/wet-cup. 11. Pump rod damage 11. Repair pump. See pump manual 310643 or 310894. 12. Low stall pressure 12. Turn pressure knob fully clockwise. Make sure pressure control knob is properly installed to allow full clockwise position. If problem persists, replace pressure transd
. Operation Pressure Relief Procedure Using the Gun WARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or dispensing accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: . are instructed to relieve the pressure, . stop dispensing, . check or service any of the syst
b.)Vuelva a colocar la boquilla de giro SwitchTip en su posicion original. c.) Suelte el seguro del gatillo y siga pulverizando. 1 a.) Rilasciare il grilletto ed inserire la sicura della pistola. b.) TOGLIERE la sicura e premere il grilletto per liberare l’ostruzione. Non puntare mai la pisola sulle mani o in uno straccio! 2 a.) Inserire la sicura, b.) rimettere lo SwitchTip nella posizione originale, c.) TOGLIERE la sicura e continuare a spruzzare. 1 a.) Solte o gatilho e coloque o dispositivo
6. Without the tip installed, start the pump or sprayer and flush it according to the pump or sprayer instructions. Prime the pump or sprayer with the fluid you are going to spray. Continued on the next page. ....... . Installation 7. Follow the Pressure Relief Procedure on page 6. 8. Engage the gun safety ring (20), see Fig. 2, page 6. 9. Unscrew the tip guard (17) and install the spray tip (A) and gasket (16) in the tip guard nut. See Fig. 1, page 4. NOTE: The gun will leak if the tip gasket (