Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Alcatel-Lucent, modelo 34970A

Fabricar: Alcatel-Lucent
Tamaño del archivo: 289.83 kb
Nombre del archivo: 278ee425-5ce9-4bbf-91e8-0f05353b0fa5.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


• Braces ( { } ) enclose parameter choices within a command string. • Triangle brackets ( < > ) enclose parameters for which you must substitute a value. • A vertical bar ( | ) separates multiple parameter choices. Rules for Using a Channel List Many of the SCPI commands for the 34970A include a scan_list or ch_list parameter which allow you to specify one or more channels. The channel number has the form (@scc), where s is the slot number (100, 200, or 300) and cc is the channel number. You can specify a single channel, multiple channels, or a range of channels as shown below. • The following command configures a scan list to include only channel 10 on the module in slot 300. ROUT:SCAN (@310) • The following command configures a scan list to include multiple channels on the module in slot 200. The scan list now contains only channels 10, 12, and 15 (the scan list is redefined each time you send a new ROUTe:SCAN command). ROUT:SCAN (@210,212,215) • The following command configures a scan list to include a range of channels. When you specify a range of channels, the range may contain invalid channels (they are ignored), but the first and last channel in the range must be valid. The scan list now contains channels 5 through 10 (slot 100) and channel 15 (slot 200). ROUT:SCAN (@105:110,215) Scan Measurement Commands (see page 226 in the User’s Guide) MEASure :TEMPerature? {TCouple|RTD|FRTD|THERmistor|DEF} ,{|DEF}[,1[,{|MIN|MAX|DEF}]] ,(@) :VOLTage:DC? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :VOLTage:AC? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :RESistance? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :FRESistance? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :CURRent:DC? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :CURRent:AC? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :FREQuency? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :PERiod? [{|AUTO|MIN|MAX|DEF} [,|MIN|MAX|DEF}],] (@) :DIGital:BYTE? (@) :TOTalize? {READ|RRESet} ,(@) Monitor Commands (see page 237 in the User’s Guide) ROUTe :MONitor (@) :MONitor? ROUTe :MONitor:STATe {OFF|ON} :MONitor:STATe? ROUTe:MONitor:DATA? Scan Statistics Commands (see page 233 in the User’s Guide) CALCulate :AVERage:MINimum? [(@)] :AVERage:MINimum:TIME? [(@)] :AVERage:MAXimum? [(@)] :AVERage:MAXimum:TIME? [(@)] :AVERage:AVERage? [(@)] :AVERage:PTPeak? [(@)] :AVERage:COUNt? [(@)] :AVERage:CLEar [(@)] DATA:LAST? [,][(@)] This command redefines the scan list when executed. Default parameters are shown in bold. 2 Scan Configuration Commands (see page 226 in the User’s Guide) ROUTe :SCAN (@) :SCAN? :SCAN:SIZE? TRIGger :SOURce {BUS|IMMediate|EXTernal|ALARm1|ALARm2|ALARm3|ALARm4|TIMer} :SOURce? TRIGger :TIMer {|MIN|MAX} :TIMer? TRIGger :COUNt {|MIN|MAX|INFinity} :COUNt? ROUTe :CHANnel:DELay [,(@)] :CHANnel:DELay? [(@)] :CHANnel:DELay:AUTO {OFF|ON}[,(@)] :CHANnel:DELay:AUTO? [(@)] FORMat :READing:ALARm {OFF|ON} :READing:ALARm? :READing:CHANnel {OFF|ON} :READing:CHANnel? :READing:TIME {OFF|ON} :READing:TIME? :READing:UNIT {OFF|ON} :READing:UNIT? FORMat :READing:TIME:TYPE {ABSolute|RELative} :READing:TIME:TYPE? ABORt INITiate READ? Scan Memory Commands (see page 235 in the User’s Guide) DATA:POINts? DATA:REMove? SYSTem:TIME:SCAN? FETCh? R? [] This command redefines the scan list when executed. This command applies to all channels in the instrument (Global setting). Default parameters are shown in bold. 3 Scanning With an External Instrument (see page 239 in the User’s Guide) ROUTe :SCAN (@) :SCAN? :SCAN:SIZE? TRIGger :SOURce {BUS|IMMediate|EXTernal|TIMer} :SOURce? TRIGger :TIMer {|MIN|MAX} :TIMer? TRIGger :COUNt {|MIN|MAX|INFinity} :COUNt? ROUTe :CHANnel:DELay [,(@)] :CHANnel:DELay? [(@)] ROUTe :CHANnel:ADVance:SOURce {EXTernal|BUS|IMMediate} :CHANnel:ADVance:SOURce? ROUTe :CHANnel:FWIRe {OFF|ON}[,(@)] :CHANnel:FWIRe? [(@)] INSTrument :DMM {OFF|ON} :DMM? :DMM:INSTalled? This command redefines the scan list when executed. This command applies to all channels in the instrument (Global setting). Default parameters are shown in bold. 4 Temperature Configuration Commands (see page 219 in the User’s Guide) CONFigure :TEMPerature {TCouple|RTD|FRTD|THERmistor|DEF} ,{|DEF}[,1[,{|MIN|MAX|DEF}]] ,(@) CONFigure? [(@)] UNIT :TEMPerature {C|F|K}[,(@)] :TEMPerature? [(@)] [SENSe:]TEMPerature:TRANsducer :TYPE {TCouple|RTD|FRTD|THERmistor|DEF}[,(@)] :TYPE? [(@)] [SENSe:]TEMPerature...

Otros modelos de este manual:
Equipo de red - 34970A (289.83 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría