|
Resumen del manual
Refer to the list of supported drivers in section 2.1. 2.6 Configuring the SmartView Multiscreen The SmartView Multiscreen is supplied pre-configured with factory defaults which are suitable for most applications. There are a number of more advanced options which can be set by the user. These are stored in the SmartView Multiscreen's EEPROM memory and are retained when the power is disconnected. The options may be changed whilst the SmartView Multiscreen is in configure mode. You may enter configure mode at initial power on or whilst the SmartView Multiscreen is running: SmartView Multiscreen Installation and Use Page 14 To enter configure mode at power on: Switch off all the attached PCs and the SmartView Multiscreen. Hold down the front panel key whilst powering on the SmartView Multiscreen. Remember that the SmartView Multiscreen draws its power from any attached PC via the keyboard cable and so will power itself on when the attached PC is switched on or when the optional power adapter is connected. Do not release the key until the SmartView Multiscreen displays 'C' to show that it has entered configure mode. To enter configure mode whilst the SmartView Multiscreen is running: Hold down the front panel key for 5 seconds until the front panel display shows ‘C’. In configure mode, options are entered by typing a letter followed by a number followed by (return). Use ESC to abort the entry of an option. The SmartView Multiscreen will remain in configure mode until you type 'E' (return). For example: to set hotkey option 2 type the following at the 'C' prompt (at SmartView Multiscreen 'C' prompt) H HH2 22f ff To exit configure mode type: E EEf ff 2.7 Summary of SmartView Multiscreen configuration options Full details of each of the configuration options and their uses are given in section 4. B1 - screen saver disabled (default) B2 - Blank screen after 1 minute of inactivity B3 - Blank screen after 2 minutes of inactivity B4 - Blank screen after 4 minutes of inactivity B5 - Blank screen after 8 minutes of inactivity B6 - Blank screen after 12 minutes of inactivity B7 - Blank screen after 16 minutes of inactivity B8 - Blank screen after 20 minutes of inactivity SmartView Multiscreen Installation and Use Page 15 L1 - SmartView Multiscreen locks on to active ports only during autoscanning (default) L2 - SmartView Multiscreen locks on to every port during autoscanning L3 - SmartView Multiscreen powers on in autoscan mode and locks on to active ports only L4 - SmartView Multiscreen powers on in autoscan mode and locks on to all ports L5 – Allow the mouse to run at any speed (default) L6 – Don't allow the mouse to run at very slow speeds L7 - Cascade query code = AD (default) L8 - Cascade query code = EF T1 - 2 seconds autoscan delay time before switching to next port (default) T2 - 5 seconds autoscan delay time before switching to next port T3 - 7 seconds autoscan delay time before switching to next port T4 - 10 seconds autoscan delay time before switching to next port T5 - 15 seconds autoscan delay time before switching to next port T6 - 20 seconds autoscan delay time before switching to next port T7 - 30 seconds autoscan delay time before switching to next port T8 - 60 seconds autoscan delay time before switching to next port U1 - SmartView Multiscreen channels are switchable using a 3 button mouse or IntelliMouse (default) (SmartView Multiscreen reports 2 button mouse mode to PCs) U2 - SmartView Multiscreen channels are not switchable using 3 button mouse or IntelliMouse (SmartView Multiscreen reports 2 button mouse mode to PCs) U3 - SmartView Multiscreen channels are not switchable using 3 button mouse or IntelliMouse (SmartView Multiscreen reports 3 button mouse mode to PCs) U4 - SmartView Multiscreen channels are switchable using 3 button mouse or IntelliMouse (SmartView Multiscreen reports IntelliMouse mode to PCs) U5 - SmartView Multiscreen channels are not switchable using 3 button mouse or IntelliMouse (SmartView Multiscreen reports IntelliMouse mode to PCs) SmartView Multiscreen Installation and Use Page 16 U7 – Cycle between all ports when switching with ‘Hotkeys + Tab’ or three button mouse (default) U8 – Cycle between active ports only when switching with ‘Hotkeys + Tab’ or three button mouse H1 - Hotkey combination is CTRL + ALT + command key (default) H2 - Hotkey combination is CTRL + SHIFT + command key H3 - Hotkey combination is ALT + SHIFT + command key H4 - Hotkey combination is RIGHT ALT + command key H5 - Hotkey combination is LEFT ALT + RIGHT ALT + command key H6 - Hotkey combination is LEFT CTRL + LEFT ALT + command key H7 - Hotkey combination is RIGHT CTRL + RIGHT ALT + command key H8 - No hotkey combination enabled F1 - Display firmware first digit (Note: F1 is F FFfollowed by 1 11NOT l ll) F2 - Display firmware second digit F3 - Display firmware third digit F5 - Restore PS/2 mouse function F6 - Restore IntelliMouse function F8 - RESET all configurations to default settings. (Display confi...
Otros modelos de este manual:Equipo de red - SVMS2-QUAD (2.48 mb)
Equipo de red - SVMS4-QUAD (2.48 mb)