Resumen del manual


Addition of the card in progress...
[ NOTE: Killing or otherwise aborting this olrad command may not cancel the Card Add operation. ]
H/W Path Class Description
=====================================================
5/0/6/0/0/0 slot PCI Slot
5/0/6/0/0/0/0 fc PCIe SerialBus (10772532)
Error : ioscan failed! card not claimed
Target slot : 8-0-1-5
Error : On line ADD failed !! Attention LED may be left in blinking state
Target slot : 8-0-1-5
-------------------------------------------------------
Additionally, syslog will contain messages similar to the following:
vmunix: FCD: Allocate shared memory failed, error code = -1
vmunix: init of hardware not successful. id=10772532 and my_isc=2
Corrective action: Retry the operation at a time when the system has more free memory
available.

DLKM infrastructure must be installed
A complete Dyamically Loadable Kernel Module (DLKM) infrastructure is required for
FibrChanl-01 B.11.31.0803. This requires that the following kernel patches be installed:

PHKL_36387: MCA recovery/shutdown patch

PHKL_36332: Cumulative GIO patch

PHCO_36371: PCI OL* DLKM and Chassis Delete
These patches and other required patches are delivered in the FEATURE11i patch bundle
on the HP-UX 11i v3 (B.11.31) OEUR media for September 2007. You may also check
availability of the patch at the HP IT Resource Center site: http://itrc.hp.com

crashconf displays incorrect size for dump devices
FibrChanl-01 now supports dump devices that are greater than 2TB in size. However,
crashconf displays an incorrect size for dump devices that are greater than 4TB.
Corrective action: Install patch PHCO_36550 to fix this problem. This patch is delivered in
the HWEnable11i patch bundle on the HP-UX 11i v3 (B.11.31) OEUR media for December
2007. You may also check availability of the patch at the HP IT Resource Center site: http://
itrc.hpc.om


Critical Resource Analysis (CRA) may unexpectedly fail
Critical Resource Analysis (CRA) may unexpectedly fail during Online Replacement (OLR),
Online Deletion (OLD), or during dynamic unload of the fcd driver module, causing a core
dump.
OLR occurs when performing a replacement operation with the olrad command, PCI attention
button, or the System Management Homepage (SMH) on systems with this OLR feature.
OLD occurs when performing a delete operation with the olrad command, or with the Systems
Management Homepage (SMH) on systems with this OLD feature.
A dynamic module unload can occur with kcmodule, swinstall, or swremove commands.
If the CRA fails in this way during a swinstall or swremove operation, the system will
automatically reboot to complete the requested operation. If the CRA fails during a kcmodule
fcd=unused operation, the unload action will not occur until the system is manually rebooted.
Corrective action: Install patch PHCO_36356 to fix this problem. This patch is delivered in
the HWEnable11i patch bundle on the HP-UX 11i v3 (B.11.31) OEUR media for December
2007. You may also check availability of the patch at the HP IT Resource Center site: http://
itresourcecenter.hp.com

Known problems and limitations
5


...

Otros modelos de este manual:
Equipo de red - HP-UX 11i v3 I/O Cards (221.31 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría