Iniciar sesión:
Votos - 1, Puntuación media: 4 ( )

Manual de usuario Echo, modelo PB-260L

Fabricar: Echo
Tamaño del archivo: 460.1 kb
Nombre del archivo: e856f072-7dab-c974-7966-d19da26a43b5.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


SAFETY DECAL -Lists important safety precautions. 2. SPARK PLUG -Provides spark to ignite fuel mixture. 3. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER -The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep exhaust area clear of flammable debris. 4. RECOIL STARTER HANDLE - Pull recoil handle slowly until starter engages, then quickly and firmly. When engine starts, return handle slowly. DO NOT let handle snap back or damage to unit will occur. 5. FUEL TANK CAP -Covers and seals fuel tank. 6. FUEL TANK- Contains fuel and fuel filter. 7. AIR CLEANER -Contains replaceable air filter element. 8. SERIAL NUMBER LABEL - Located on underside of unit below starter housing. Lists model number and serial number of unit. 9. HANDLE -Rotates downward for throttle control access. Spring loaded for flexible operation. 10. THROTTLE POSITION LEVER/STOP SWITCH -Combination stop switch and variable speed throttle lever. When the lever is moved all the way forward the blower is at Wide Open Throttle (W.O.T.). When the lever is moved rearward to detent, the blower is at idle. When the lever is moved rearward past the idle detent the blower will stop. 11. CHOKE -Move lever DOWN to close choke (starting position) and for emergency stopping. Move UP to open choke (run position). 12. PRIMER BULB - Pumping primer bulb before starting engine draws fresh fuel from the fuel tank priming the carburetor for starting. Pump primer bulb until fuel is visible and flows freely in the clear fuel tank return line. Pump bulb an additional 4 or 5 times. 13. SHOULDER HARNESS -Used to support unit on operator's back. The straps are adjustable. 14. BLOWER PIPES -Twist lock design. 15. FLEXIBLE PIPE -Allows for full range of movement. POWER BLOWER OPERATOR'S MANUAL POWER BLOWER OPERATOR'S MANUAL S MODEL PB-260L PB-261L Length 310 mm (12.62in.) Width 410 mm (1861 in.) Height 460 mm (18.1 in.) Weight with pipes 6.6 kg (14.5 lb.) Engine Type Air cooled, two-stroke, single cylinder gasoline engine Displacement in.)25.4 cc (1.55 cu. Bore 34.0 cc (1.34 in.) Stroke 28.0 mm (1.10 in.) Carburetor Walbro Diaphragm, model w/primer bulb Ignition System Flywheel Magneto, capacitor discharge ignition type Spark Plug NGK BPM-7YGap 0.65 mm (0.026 in.) Exhaust System Spark Arrestor Muffler Spark Arrestor Muffler w/Catalyst Fuel Mixed (Gasoline and Two-stroke Oil) Fuel/Oil Ratio 50:1 ECHO High Performance, two-stroke air cooled engine oil Gasoline DO NOT use fuel containing methyl alcohol, more89 Octane unleaded. than 10% ethyl alcohol or 15% MTBE. Oil 50:1 ECHO High Performance, two-stroke air cooled engine oil Fuel Tank Capacity oz.)(17.75 US fl.0.6 lit. Recoil Starter System Automatic Recoil Starter Centrifugal Type Idle Speed 3200-3000 (RPM) Wide Open Throttle Speed 7400 (RPM) Maximum Maximum Air Speed (Measured at pipe end) 69.3 m/sec. (155.0 mph) Average Air Volume (Measured at pipe end) 10.6 cmm (375 CFM) dBSound Level at 50 ft. (A) scale per ANSIB175.2 65 dB(A) 10 10 Y WARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INSTALL BLOWER PIPES 1. Remove elbow retaining screw from blower housing. 2. Align grooves in elbow with pegs on blower housing and slide pipe onto housing. 3. Turn elbow clockwise to lock into place and align location holes (A) in elbow and blower housing. 4. Insert elbow retaining screw through holes (A) and tighten. 5. Assemble clamps (B) onto both ends of flexible pipe (C). 6. Assemble straight pipe with swivel (D) into flexible pipe (C) and tighten clamp (B). 7. Assemble flexible pipe (C) to elbow (E) on blower and tighten clamp (B). 8. Loosen wing nut (F) completely and expand stick handle (G). 9. Align notch (H) in handle clamp with pipe pegs (J). Handle should be angled away from operator. 10. Slide handle onto swivel pipe. 11. Position handle for comfortable operation and tighten wing nut. 12. Assemble straight pipe (K and L) to swivel pipe, turning straight pipe clockwise to lock in place. A A E K C D GL F BB H G J J K L F POWER BLOWER OPERATOR'S MANUAL POWER BLOWER OPERATOR'S MANUAL Fuel Requirements R + M Gasoline -Use 89 Octane [ 2 ] (mid grade or higher) gasoline known to be good quality. Gasoline may contain up to 15% MTBE (methyl tertiary-butyl ether). Gasohol containing methyl (wood) alcohol is NOT approved. Two Stroke Oil -A two-stroke engine oil meeting ISO-L-EGD (ISO/CD 13738) and J.A.S.O. FC Standards, must be used. Echo brand Premium 50:1 oil meets these standards. Engine problems due to inadequate lubrication caused by failure to use an ISO-L-EGD and J.A.S.O. FC certified oil, such as Echo Premium 50:1 Two-stroke Oil, will void the two-stroke engine warranty. (Emission related parts only are covered for two years, regardless of two-stroke oil used, per the statement listed in the EPA Phase 2/California Emission Defect Warranty Explanation.)...

Otros modelos de este manual:
Los sistemas de ventilación - PB-261L (460.1 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría