Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  
Descargado: 7   Tamaño del archivo: 173 kb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

Interface 3, 20 RXAUX RX RS232 Aux. Interface 4 RTX485 - RTX- RS485 Main Interface 5 RTX485 + RTX+ RS485 Main Interface 7 SGND Signal Ground 8 OUT1 + Output 1 + 11 OUT2 + Output 2 + 18 EXT TRIG + External trigger + 19 EXT TRIG - External trigger - 10, 12, 22 I/O REF Input/Output reference 17 IN1 - Input 1 - 6, 14, 15, 16, 23, 24 N.C. Not Connected * Pins 1 and 25 are connected together internally. 851000292 (Rev. B) Power Supply Power can be supplied to the scanner through the pin

Descargado: 28   Tamaño del archivo: 822 kb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

Please be prepared to provide information about the store/chain, location, POS system and other pertinent information about the scanner being repaired. Programming Guide 7 000 010 000 Where To Go From Here Programming is easy and straightforward if you follow these steps: 1. If you are changing interfaces, first connect the scanner to the new host using the new interface cable. Scan the interface enable bar code label1 . 2. Scan any feature labels that are unique to the interface you are

Descargado: 265   Tamaño del archivo: 822 kb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

Selecting this feature also changes the symbology ID to match those required for EAN-13. UPC-A or UPC-E and EAN-8 or EAN-13 Two and Five Digit AddOns Optional — scanner will read UPC/EAN bar codes with or without add-ons. Required — UPC/EAN bar codes must have add-on or label will not be read. Disable — scanner will not recognize/read add-on portion of UPC/ EAN labels, but will read the main body of the label. Price/Weight Check Digit — provides options for enabling price/ weight check dig

Descargado: 78   Tamaño del archivo: 1 mb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

Definitions. 1.1 "Documentation" means materials such as user’s guides, program reference guides, quick reference guides, manuals, or similar materials associated with or related to the Datalogic Product, whether in printed, “online”, or other form. 1.2 "Proprietary Information" means: (a) source code, object code, software, documentation, and any related internal design, system design, data base design, algorithms, technology, technical data or information, implementation techniques, and trade

Descargado: 108   Tamaño del archivo: 628 kb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. * On Off Product Reference Guide Output Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the imager emits on a good read. Default = Medium. High * Medium Off Low Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the imager emits on a good read. Default = Medium. Low (1400 Hz) Medium (

Descargado: 23   Tamaño del archivo: 271 kb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

With 1MB of RAM memory for managing large databases and 512KB of Flash memory for application programs, these terminals solve the most complex application needs and exploit the “overspeed” feature to boost software performance. Equipped with a practical 25-key alphanumeric keyboard that allows data, codes and descriptions to be input very quickly and a wide backlit LCD display which clearly shows much information, these devices represent the ideal solution for many applications in the Retail, Tr

Descargado: 1   Tamaño del archivo: 2 mb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Mobile, Inc. or its affiliates or subsidiaries ("Datalogic" or “Datalogic Mobile”) . Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any propri

Descargado: 42   Tamaño del archivo: 3 mb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

MSI/PLESSEY AIM ID = DISABLE MSI/PLESSEY AIM ID = ENABLE Product Reference Guide 6-253 MSI/Plessey Label ID This feature specifies an MSI/Plessey label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY LABEL ID below. You’ll need to cover any unused bar codes on this and the f

Descargado: 935   Tamaño del archivo: 4 mb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

The other two pairs are FFFF and FFFF. With the label, AG15TA81, it would look as follows after the character conversion: BG25TB82. The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character. Nothing is done with the last two character pairs, since they are all FF. To set Character Conversion: 1. Scan the START/END bar code. 2. Scan the Character Conversion bar code. 3. Determine the desired string. Up to sixteen positions can be determined

Descargado: 0   Tamaño del archivo: 826 kb   Fabricar: Datalogic Scanning  
Categoría: escáner / copiadora / impresora multifunción
@name

START / END PROGRAMMING BAR CODES 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour Magellan® 1400i LED and Beeper Indicators LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation. START / END PROGRAMMING BAR CODES Disable Enable DEFAULT Product Reference Guide General Features Good Read: When to Indicate This feature specifies





Categoría