Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Speed Queen, modelo Drying Tumblers JCB30CSH

Fabricar: Speed Queen
Tamaño del archivo: 703.49 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Do not install a hot water heater in room containing tumblers. It is better to have the water heater in a separate room with a separate air inlet. Figure 1 M412616 33 VERTICAL EXHAUST INSTALLATION HORIZONTAL EXHAUST INSTALLATION CONNECT TO TUMBLER 2" (5.1 cm) MINIMUM WALL 2" (5.1 cm) MINIMUM EXHAUST OUTLET NO SCREEN WALL CONNECT TO TUMBLER EXHAUST AIR FLOW MAXIMUM LENGTH OF DUCT 14 FEET (4.3 m) OR CAP T030IE3B NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm) LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING. Figure 2 NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm) INSPECTION OR LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE CLEANOUT COVER PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING. T056IE3B AL K J I H G F E D C B 45° WALL NO SCREEN OR CAP AIR OUT 2" (5.1 cm) MINIMUM DUCT STATION MINIMUM DIAMETER DUCT STATION MINIMUM DIAMETER *GAS ELECTRIC STEAM *GAS ELECTRIC STEAM A 9" (22.9 cm) 10" (25.4 cm) G 23" (58.4 cm) 26" (66 cm) B 12" (30.5 cm) 14" (35.6 cm) H 25" (63.5 cm) 28" (71.1 cm) C 15" (38.1 cm) 17" (43.2 cm) I 26" (66 cm) 30" (76.2 cm) D 17" (43.2 cm) 20" (50.8 cm) J 27" (68.6 cm) 31" (78 cm) E 19" (48.3 cm) 22" (55.9 cm) K 29" (73.9 cm) 33" (83.8 cm) F 21" (53.3 cm) 24" (61 cm) L 30" (76.2 cm) 34" (86.4 cm) Figure 3 34 M412616 ELECTRICAL REQUIREMENTS For 30 Pound (13 kg) Narrow Cabinet Tumblers REQUIREMENTS Heat Source Electrical Specs Wires Required and Terminal Block Connection Gas 230-50-1 L1 L2 Ground to PE Busbar Electric 230-50-1 L1 L2 Ground to PE Busbar Electric 230-50-3 L1 L2 L3 Ground to PE Busbar Electric 380-50-3 L1 L2 L3 Ground to PE Busbar Electric 415-50-3 L1 L2 L3 Ground to PE Busbar Figure 4 GAS DRYING TUMBLERS GAS DRYING TUMBLERS 240V, 1 Phase, 50 Hz. 120V, 1 Phase, 30 Hz. Minimum Wire Size 14 AWG (2.081 mm.) 14 AWG (2.081 mm.) Circuit Breaker 15 AMP 15 AMP No. of Poles 2 2 Figure 5 ELECTRIC DRYING TUMBLERS ELECTRIC DRYING TUMBLERS 240V 50 Hz. 1 Ph 240V 50 Hz. 3 Ph 380V 50 Hz. 3 Ph 415V 50 Hz. 3 Ph Amp Rating 91 Amp 55 Amp 34 Amp 31 Amp Circuit Breaker 100 Amp 60 Amp 40 Amp 35 Amp Poles 2 3 3 3 Minimum Wire Size 2 AWG (33.63 mm.) 6 AWG (13.32 mm.) 8 AWG (8.366 mm.) 8 AWG (8.366 mm.) Figure 6 GROUNDING INSTRUCTIONS Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to PE Busbar. . WARNING To reduce the risk of fire and electric shock, check with a qualified serviceman for proper grounding procedures. Improper connection of the equipment grounding conductor can result in a risk of electric shock. . WARNING To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine. M412616 35 ELECTRICAL REQUIREMENTS For 30 Pound (13 kg) Tumblers REQUIREMENTS Heat Source Electrical Specs Wires Required and Terminal Block Connection Gas & Steam 230/50/1 L1 L2 Ground to PE Busbar Electric 230/50/1 L1 L2 Ground to PE Busbar Electric 380/50/3 L1 L2 L3 Ground to PE Busbar Electric 415/50/3 L1 L2 L3 Ground to PE Busbar Steam 380/50/3 L1 L2 L3 Ground to PE Busbar Figure 7 GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS 240 V, 1 Phase, 50 Hz. 380 V, 3 Phase, 50 Hz. Minimum Wire Size 14 AWG (2.081 mm.) 14 AWG (2.081 mm.) Circuit Breaker 15 AMP 15 AMP Poles 2 2 Figure 8 ELECTRIC DRYING TUMBLERS NOTE: DO NOT use aluminum wire. ELECTRIC DRYING TUMBLERS 240 V, 1 Ph, 50 Hz. 240 V, 3 Ph, 50 Hz. 380 V, 3 Ph, 50 Hz. 415 V, 3 Ph, 50 Hz. Minimum Wire Size 2 AWG (33.63 mm.) 6 AWG (13.32 mm.) 8 AWG (8.366 mm.) 8 AWG (8.366 mm.) AMP Rating 90 Amp 54 Amp 33 Amp 30 Amp Circuit B...

Otros modelos de este manual:
Secadoras - Drying Tumblers JC50CE (703.49 kb)
Secadoras - Drying Tumblers JC50CG (703.49 kb)
Secadoras - Drying Tumblers JC50CSH (703.49 kb)
Secadoras - Drying Tumblers JC50EG (703.49 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría