Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Panasonic, modelo TH-37PR10U

Fabricar: Panasonic
Tamaño del archivo: 4.04 mb
Nombre del archivo: TH37PR10U.PDF
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:
TV - TH-37PR10U (3.73 mb)es

Resumen del manual


SERIAL 6 7 8 9 1 3 4 52 Pin layout for SERIAL Terminal COMPUTER RS-232C Straight cable D-sub 9p Notes: • Use the RS-232C cable to connect the computer to the Plasma Display. • The computer shown is for example purposes only. • Additional equipment and cables shown are not supplied with this set. The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal. The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details. Communication parameters Signal level RS-232C compliant Synchronization method Asynchronous Baud rate 9600 bps Parity None Character length 8 bits Stop bit 1 bit Flow control - RS-232C Conversion cable D-sub 9-pin female Details 2 R X D 3 T X D 5 GND 4 • 6 Non use 7 8 Shorted 1 • 9 NC Start 3-character Colon Parameter(s) (1 - 5 bytes) STX C1 C2 C3 P1 P2 P3 P4: P5 ETX Basic format for control data Command The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent. End (03h) (02h) command (3 bytes) Notes: • If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command. • If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer. • SL1A, SL1B, SL2A and SL2B of Command IMS are available only when a dual input terminal board is Command Parameter Control details PON None Power ON POF None Power OFF AVL ** Volume 00 - 63 AMT 0 Audio MUTE OFF 1 Audio MUTE ON IMS None SL1 SL2 SL3 PC1 SL1A SL1B SL2A SL2B Input select (toggle) Slot1 inputSlot2 inputSlot3 inputPC inputSlot1 input (INPUT1A) Slot1 input (INPUT1B) Slot2 input (INPUT2A) Slot2 input (INPUT2B) DAM None NORM ZOOM FULL JUST SELF Screen mode select (toggle) NORMAL (4 : 3) ZOOM FULL JUST Panasonic AUTO With the power off, this display responds to PON command only. attached. Power ON / OFF Connecting the AC cord plug to the Plasma Display. Fix the AC cord plug securely to the Plasma Display with the clamper. (see page 9) Connecting the plug to the Wall Outlet Note: When disconnecting the AC cord, be absolutely sure to disconnect the AC cord plug at the socket outlet first. Press the Power switch on the Plasma Display to turn the set on: Power-On. Power Indicator: Green Example: The screen below is displayed for a while after the Plasma Display is turned on. (setting condition is an example.) POWER Remote Control Sensor Power Indicator Press the button on the remote control to turn the Plasma Display off. Power Indicator: Red (standby) Press the button on the remote control to turn the Plasma Display on. Power Indicator: Green Turn the power to the Plasma Display off by pressing the switch on the unit, when the Plasma Display is on or in standby mode. Note: During operation of the power management function, the power indicator turns orange in the power off state. Initial selections Selecting the input signal Select the input signals to be connected by installing the optional Terminal Boards. Press to select the input signal to be played back from the equipment which has been connected to the Plasma Display. Input signals will change as follow: INPUT1 INPUT2 INPUT3 PC Notes: • Selecting is also possible by pressing the INPUT button on the unit. • Input terminal will not be selected if the terminal board is not installed into the SLOT. • Select to match the signals from the source connected to the component/RGB input terminals. (see page 32) • In 2 screen display, the same input mode cannot be selected for the main picture and sub picture. MENU ENTER/INPUT VOL Swing up the door at “PULL”. Selecting the On-Screen Menu Language 1/2 PC OFF STANDBY SAVE OFF POWER MANAGEMENT OFF AUTO POWER OFF OFF OSD LANGUAGE ENGLISH (US) COMPONENT/RGB-IN SELECT RGB INPUT LABEL SIGNAL POWER SAVE SET UP .......(Japanese) .......(Chinese) Italiano Francais Deutsch English(UK) Espanol ENGLISH(US) .......(Russian)Русский Press to display the SET UP menu. Press to select OSD LANGUAGE. Press to select your preferred language. Selectable languages Basic Controls MENU POWER ENTER/INPUT VOL Remote control sensor Power Indicator The Power Indicator will light. • Power-OFF .... Indicator not illuminated (The unit will still consume some power as long as the power cord is still inserted into the wall outlet.) • Standby ......... Red • Power-ON ......Green • DPMS .............Orange (With PC input signal and during operation of PC’s screensaver.) Main Power On / Off Switch ON OFF ONSURROUND N button (see page 19, 22, 23, 24) POS. /SIZE button (see page 19) PICTURE button (see pa...

Otros modelos de este manual:
TV - TH-42PR10U (4.04 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría