Iniciar sesión:
Votos - 1, Puntuación media: 4 ( )

Manual de usuario Furman Sound, modelo AC LINE VOLTAGE REGULATOR AR-15

Fabricar: Furman Sound
Tamaño del archivo: 1.19 mb
Nombre del archivo: 7aa0e972-e784-4470-8b85-8f51e91b3d8d.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


AR-15 FEATURES • Provides nine regulated, conditioned AC outlets—eight on the rear panel and one onthe front • Series mode protection plus (SMP+) withextreme voltage shutdown (E.V.S.) • LiFT (Linear Filtering Technology) with zero ground contamination • Eight rear panel outlets and one frontpanel outlet • BNC connector on the rear panel allowsyou to attach any standard (12VAC 0.5 amp) gooseneck lamp to illuminate therear of your rack • Extreme Voltage Shutdown indicator LED • Output In Regulation indicator • Ten-LED bargraph input voltmeter • Fast-acting user-accessible circuit breakerprotects against overload or shorts • Very low stray magnetic field leakage • Input capacity is 15 A; output capacity is 12 to 15 A SAFETY INFORMATION To obtain best results from your Furman AR-15 please be sure to read this manual carefully. WARNING: To reduce the risk of electrical shock, do not expose this equipment to rain or moisture. Dangerous high voltages are present inside the enclosure. Do not remove the covers. There are no user serviceable parts inside. Refer servicing to qualified personnel only. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock. IMPORTANT SAFETY INSTRUCTIONS PLEASE READ PRIOR TO INSTALLATION 1. Please read and observe all of the safety and operating instructions before the AR-15 is operated. Retain these instructions for future reference. 2. The AR-15 should not be used near water — for example, near a bathtub, kitchen sink, in a wet basement, near a swimming pool, etc. 3.Do not place the AR-15 near heat sources such as radiators, heat registers, stoves, or other appliances that produce heat. 4. Route the power cord and other cables so that they are not likely to be walked on, tripped over, or stressed. Pay particular attention to condition of cords and cables at plugs, and the point where they exit from the AR-15. To prevent risk of fire or injury, damaged cords and cables should be replaced immediately. AR-15 VOLTAGE REGULATOR / POWER CONDITIONER 5. Clean the AR-15 with a damp cloth only. Do not use solvents or abrasive cleaners. Never pour any liquid on or into the unit. 6. When left unused for a long period of time, the power cord of the AR-15 should be unplugged from the outlet. 7. The AR-15 should be serviced by qualified service personnel when: a. The power supply cord or the plug has been frayed, kinked, or cut. b. Objects have fallen or liquid has spilled into the unit. c. The AR-15 has been exposed to rain or other moisture. d. The AR-15 does not appear to operate normally or exhibits a marked change in performance. e. The AR-15 has been dropped, or the enclosure damaged. 8. The AR-15 requires that a safety ground be present for proper operation. Any attempt to operate the AR-15 without a safety ground is considered improper operation and could invalidate the warranty. 9. There are no user serviceable parts in the AR-15. Refer servicing to qualified service personnel only. Voltage Regulation Furman Voltage Regulators are intended to protect sensitive electronic equipment from problems caused by AC line voltage irregularities— brownouts or overvoltages that can cause audio tonal changes, digital equipment malfunction (such as loss of MIDI programs or other data), or, in extreme cases, permanent damage. They accept input voltages over a wide AC voltage range and convert them to a steady, stable output at the desired standard voltage, plus or minus five volts. Voltages approximately ±10% beyond that range may be converted to usable levels, depending on the requirements of the equipment. This stable voltage protects equipment and allows optimal performance. See graphs on the back page. The AR-15 has eight outlets on the rear panel, and one convenience outlet on the front panel. All are functionally interchangeable. The outlets are regulated, surge-suppressed, and linearly filtered, making the unit a full-function power conditioner. The AR-15 has no controls except an on-off switch and the switch for the optional rear rack light. Note: The AR-15 is for use with AC voltage only. DC voltages should never be applied to them. Also, it does not change or regulate line frequency. The output frequency will always be the same as the incoming frequency. SMP+ (series mode protection plus) Traditional surge suppression rely on circuits that “sacrifice” themselves when exposed to multiple transient voltage spikes, requiring the dismantling of your system, and repair of your surge suppressor. Not so with SMP+. With Furman’s SMP+, damaging transient voltages are safely absorbed, clamped, and dissipated. No sacrificed parts, no service calls, no down time. Unique to Furman’s SMP+ is its unparalleled clamping voltage. While other designs offer clamping voltages that are well above 330 Vpk, Furman’s SM...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría