NOTE:
The following HP released firmware versions are considered to be within one functional release:
• 09.09.00, 09.09.02
• 09.08.01, 09.07.02
• 09.06.02
• 09.03.00, 09.02.00, 09.00.00
• 08.02.00, 08.01.01, 08.01.00
• 07.01.03, 07.01.02, 07.00.00
If HAFM Basic is used for upgrades and downgrades, and the release version rule is not followed,
errors will occur and there may be a disruption to attached devices.
• If upgrading firmware requires an upgrade from 04.xx.xx to 05.xx.xx in the process, there are
special considerations, as described in
“Upgrading firmware on a Director from 04.xx.xx to 05.xx.xx” on page 9.
• If upgrading firmware requires an upgrade from 06.xx.xx in the process, upgrade from 06.xx.xx
to 07.01.03. This firmware includes a fix to an issue that can occur under very specific conditions
when firmware is upgraded from 06.xx.xx to 07.xx.xx . Other versions of 07.xx.xx should not
be used in the upgrade process.
• If upgrading firmware requires an upgrade from 07.xx.xx in the process, upgrade from 07.xx.xx
to 08.02.00. Firmware 08.02.00 includes a fix to a issue that can occur when firmware is up-
graded from 07.xx.xx to 08.xx.xx for the Edge Switch 2/24 and Edge Switch 2/12. Other versions
of 08.xx.xx should not be used in the upgrade process.
• A small number of Surestore Director FC-64 units that were shipped early may display one of the
following messages during the process of upgrading to firmware 05.02.00-13:
• HAFM—Firmware cannot be loaded due to insufficient CTP memory.
• HAFM Basic—File System Error: Insufficient memory for new firmware
version.
This occurs only in certain units with CTP cards. Units with CTP2 cards do not have this issue.
If you receive one of these messages during the upgrade, the firmware upgrade has failed but the
unit continues to run with the existing firmware. This occurs because before activating the new
firmware image, the upgrade process found there was not sufficient memory to complete. Contact
HP Customer Support if you receive this message.
• Some customer environments use application or host software that is affected by the restart of the
Director CTP during a HotCAT download operation. Applications that rely on inband management
servers are especially prone to problems caused by processor restart. For example, an application
may be configured to poll the Director or Edge Switch at regular intervals. The polling process
could occur during a restart period, causing the application software to react adversely. As a
solution, shut down those applications driving inband requests before the upgrade, and then restart
the applications after the upgrade completes.
Upgrading firmware on a Director from 04.xx.xx to 05.xx.xx
An issue has been identified in release 04.xx.xx if the contents of the non-volatile random access
memory (NVRAM) on the active CTP are corrupted. Once the configuration has been loaded, this
corruption is not detected until an IPL/IML, power cycle, or firmware code load. If the NVRAM on the
active CTP has corrupted contents, the firmware load can cause the configuration to reset to factory
defaults, which can cause a system outage. By using the following procedure to upgrade firmware,
Director and Edge Switch release notes
9


...

Otros modelos de este manual:
datos de dispositivos de procesamiento - HP StorageWorks Director 2/140 (181.01 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/12 (181.01 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/24 (181.01 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/32 (181.01 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría