Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario AdobeAir, modelo UD960

Fabricar: AdobeAir
Tamaño del archivo: 255.01 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


24 24 13/16 13 2 15/8 4 2. 445/8 48 14.8 1. Drain is 3/4” male hose thread. 2. Water service can be left or right for 1/4” tubing. 3. 7/8” knockout for running electrical service. Electrical Specifications HP Speed Phase Voltage Amperage NEMA Frame Shaft Diameter Motor Kit # . 1 1 115/230 12.5/6.2 56 5/8 EJ006 . 2 1 230 5.9 56 5/8 EJ020 . 1 3 208-230/460 3.0/1.5 56 5/8 EJ883 1 1 1 115/230 15.1/7.5 56 5/8 EJ007 1 2 1 230 7.3 56 5/8 EJ021 1 1 3 208-230/460 3.6/1.7 143T 7/8 EJ665 1. 1 1 115/230 14.5/6.3 143T 7/8 EJ212 1. 1 3 208-230/460 4.6/2.2 143T 7/8 EJ666 2 1 1 115/230 19.0/8.5 143T 7/8 EJ213 2 1 3 208-230/460 7.1/3.3 143T 7/8 EJ667 3 1 3 208-230/460 8.7-8.4/4.2 182T 11/8 EJ668 5 1 3 208-230/460 14.2-13.0/6.5 184T 11/8 EJ659 7. 1 3 208-230/460 20.9-19.2/9.6 213T 13/8 EJ675 • Amperage from National Electric Code. • See nameplate on actual motor for amperage in fi guring overload protector. • Single phase motors rated 230 volts can be operated at nameplate amps at 208 volts. • All 3-phase motors listed are suitable for use on evaporative coolers at 200 volts. Pump Specifications Bleed Rates GPH per Media Module Pump Volts Amps Watts GPH Blower Model Blower Motor HP Model# At 4’ Head . 1 1. 2 3 5 7. CP280 115 1.2 80 300 524 or 960 7 8 9 10 10 – – CP480 230 .6 80 300 628 or 980 – 11 13 14 16 18 Note: Pumps are available in 115 volt and 230 volt models. As a result, transforming or separate circuiting may be required for other voltages. Dual Inlet Model Dimensions MD628 or UD980 (Down Discharge), MS628 or US980 (Side Discharge) and MU628 (Up Discharge) Top View Side View - Blower Section Front View (DOWN) (UP) MD/MS/MU628 or UD/US980 Media Section Cabinet Model Number 1 Required H W D Duct Location Side Down A B C E Drain1 Location F G Media Cabi- net J Blower Cabi- net K Water2 Service Location L M Electric3 Service Location S T Blower Wheel Dia. Width Shaft Blower Pulley Pitch Dia. Skid Location N P Y Q R Media Dimension X V Pad Area Sq.Ft. DM080 or UM080 51. 831/8 491/8 31. 17. 15. 8. 13 133/8 17 491/8 71.4 123/8 18 35. 28 28 13/16 18 19 15/8 2 4 2. 445/8 48 14.8 DM120 or UM120 51. 911/8 491/8 31. 17. 15. 8. 13 173/8 21 491/8 71.4 163/8 22 35. 28 28 13/16 18 23 15/8 4 4 2. 445/8 48 14.8 1. Drain is 3/4” male hose thread. 2. Water service can be left or right for 1/4” tubing. 3. 7/8” knockout for running electrical service. Sizing Instructions Follow these steps to properly size the Industrial MasterCool. The performance or Sensible Heat Capacity of any cooler is a function of both the CFM and saturation effi ciency (which determines the delivered air discharge temperature). Sizing by only considering CFM may result in an improperly sized application. 1. Determine design conditions: Outdoor Dry-Bulb DB1 Outdoor Wet-Bulb WB1 Indoor Dry-Bulb T1 2. Determine design sensible heat load (Btuh) 3. Determine leaving air temperature (LAT): LAT = DB1 - [(DB1 - WB ) * EFF] where EFF ‘ 0.80 for 8” media or 0.90 for 12” media 4. Determine CFM required: CFM = 0....

Otros modelos de este manual:
Los humidificadores - MD628 (255.01 kb)
Los humidificadores - MS524 (255.01 kb)
Los humidificadores - MS628 (255.01 kb)
Los humidificadores - UD980 (255.01 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría