|
Resumen del manual
• Performance ratings include the effects of evaporative media in the airstream. • Belt tension should be 20 pounds for “A” section belts. • Performance shown is for installation type B: Free Inlet, Ducted Outlet. MD/MS/MU 628 or UD/US 980 Sheave Selection Motor HP Browning Bore Blower RPM / Sheave Turns Open MasterCool Part # 5 4 . 4 3 . 3 2 . 2 1 . 1 . 0 Package # Single Phase Motor Blower RPM @ 1725 Motor RPM / Sheave Turns Open 1 1VL40 5/8 230 240 249 259 268 278 288 297 307 316 326 EL110 1., 2 1VL40 7/8 230 240 249 259 268 278 288 297 307 316 326 EL112 1 1VL44 5/8 268 278 288 297 307 316 326 335 345 355 364 ESH2411 1., 2 1VL44 7/8 268 278 288 297 307 316 326 335 345 355 364 EL685 1 1VP50 5/8 326 335 345 355 364 374 383 393 403 412 422 693 1., 2 1VP50 7/8 326 335 345 355 364 374 383 393 403 412 422 686 Three Phase Motor Blower RPM @ 1750 Motor RPM / Sheave Turns Open 1, 1., 2 1VL34 7/8 185 194 204 214 224 233 243 253 263 272 282 EL116 1, 1., 2 1VL40 7/8 233 243 253 263 272 282 292 301 311 321 331 EL112 1, 1., 2 1VL44 7/8 272 282 292 301 311 321 331 340 350 360 369 EL685 1, 1., 2 1VP50 7/8 331 340 350 360 369 379 389 399 408 418 428 686 3 2VP42 11/8 253 263 272 282 292 301 311 321 331 340 350 687 3, 5 2VP50 11/8 331 340 350 360 369 379 389 399 408 418 428 688 5 2VP60 11/8 408 418 428 438 447 457 467 476 486 496 506 689 7. 2VP60 13/8 408 418 428 438 447 457 467 476 486 496 506 692 Project Submittal Sheet Models MD/MS 524, MD/MS/MU 628 — U.L. Classifi ed or UD/US 960, UD/US 980 — U.L. Listed Project SHL* Location Architect Engineer Contractor Submitted By Date *Total design sensible heat load of project. Blower Section – Motor – Motor Sheave – Pulley and Belt Kit Ref. No. Blower Section Qty. Model No. Motor Specifi cations Motor HP Volts Phase Amps Kits Motor Sheave Belt 1 2 3 4 *NOTE: Each unit (ready to operate) consists of one blower section, one blower motor, one pulley-belt kit, one motor sheave. Wet Section – Pump Ref. No. Wet Section Qty. Model No. Pump Quantity Volts Amps GPM 1 2 3 4 *NOTE: Each wet section (ready to operate) consists of one wet module and one pump. Your local MasterCool Representative of AdobeAir, Inc., is ready to assist you in unit selection and application. The world leader in evaporative cooling technology, AdobeAir, Inc. is continually involved in the process of product improvement. AdobeAir, Inc. therefore reserves the right to change specifications and/or design without prior notice. To obtain the most current product information and/or specifi cations, visit the AdobeAir, Inc. web site at Manufactured in Mexico by: AdobeAir, Inc. 1450 East Grant St. Phoenix, AZ 85034 MasterCool evaporative coolers and components are designed and tested in accordance with one or more of the following standards or agencies: Air Delivery: Data published derived from tests conducted in accordance with A.M.C.A. (Air Movement and Control Assoc.) Standard 210. Sealant: Water Immersion: per ASTM D870. ...
Otros modelos de este manual:Los humidificadores - MD628 (255.01 kb)
Los humidificadores - MS524 (255.01 kb)
Los humidificadores - MS628 (255.01 kb)
Los humidificadores - UD960 (255.01 kb)