Resumen del manual


prosecution. On completion, test the gas installation for soundness. In addition a minimum clearance of 1000mm must be available at the front of the cooker to enable the cooker to REMEMBER, when replacing a part on this appliance, be serviced. use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA. 1 03/07 EINS 511056 V = VENT PIPE S = FLUE PIPE A B C D E F G H J K L M N P Q R S T U V mm 987 889 851 679 41 1330 756 1125 39 3 698 499 127 41 530 116 770 484 328 828 Models GC and GCB Balanced flue GC GCB NATURAL G20 MAXIMUM HEAT INPUT Thermostat Bypass Main Burner Injector Pilot Injector Inlet Pressure G20 PROPANE G31 MAXIMUM HEAT INPUT Thermostat Bypass Main Burner Injector Pilot Injector Inlet Pressure Burner Pressure 5kW 100 or 120 285 N35 20mbar 5kW (357g/h) 60 or 80 180 L23 37mbar 28mbar 5kW 120 or 140 285 N35 20mbar 5kW (357g/h) 80 or 100 180 L23 37mbar 28mbar For Natural Gas the gas valve outlet pressure is non-adjustable, BUT for reference purposes only. A pressure drop of 1-2mbar can be observed between inlet and outlet pressures on a cold appliance. 2 V = VENT PIPE S = FLUE PIPE A B C D E F G H J K L M N P Q R S T U V mm 1487 889 851 679 41 1330 756 1125 39 3 698 632 591 51 67 116 770 484 328 828 Models GE and GEB Balanced flue GE GEB NATURAL G20 MAXIMUM HEAT INPUT Thermostat Bypass Main Burner Injector Pilot Injector Inlet Pressure G20 PROPANE G31 MAXIMUM HEAT INPUT Thermostat Bypass Main Burner Injector Pilot Injector Inlet Pressure Burner Pressure 5kW 100 or 120 285 N35 20mbar 5kW (357g/h) 60 or 80 180 L23 37mbar 28mbar 5.8kW 120 or 140 330 N35 20mbar 5.8kW (414g/h) 80 or 100 200 L23 37mbar 32mbar For Natural Gas the gas valve outlet pressure is non-adjustable, BUT for reference purposes only. A pressure drop of 1-2mbar can be observed between inlet and outlet pressures on a cold appliance. 3 FLUE SYSTEM The terminal is suitable for wall thicknesses from 228mm to 600mm cut size Should the installation of the appliance be in an unusual location or restricted space, special procedures may be necessary. Terminal Position The minimum acceptable spacings from the terminal to obstructions and ventilation openings are as shown in the diagram. Where the terminal is fitted within 600mm below plastic guttering an aluminium shield 1500mm long should be fitted to the underside and immediately beneath the guttering or eaves. Where the terminal is fitted within 450mm below eaves or painted guttering an aluminium shield 750mm long should be fitted to the underside and immediately beneath the guttering or eaves. Minimum siting dimensions for Balanced Flue terminals AROUND THE HOUSE DESN 511052 Position Minimum Spacing mm A Directly below an openable window, air vent, or an other ventilation opening 300 B Below gutter, drain/soil pipe 300 C Below eaves 300 D Below a balcony or car port roof 600 E From vertical drain pipes and soil pipes 300 F From internal or external corners 600 G Above adjacent ground or balcony level 300 H From surface facing the terminal 600 I Facing terminals 600 J From opening (door/window) in car port into dwelling 1200 K Vertical from a terminal 1500 L Horizontally from a terminal 300 Terminal Protection A terminal guard is supplied with the cooker and must be fitted if flue termination is less than 2 metres above ground level, or subject to damage. When fitted, it must be positioned to provide a minimum of 50mm clearance from any part of the terminal and be central over the terminal. UNDER CAR PORT, ETC. DESN 511053 4 AIR SUPPLY THE HOT WATER SYSTEM Kitchen or Internal Space Air Supply Where the appliance is to be installed in a kitchen or internal space, it does not require the kitchen or internal space containing...

Otros modelos de este manual:
Placas - GCB (139.78 kb)
Placas - GE (139.78 kb)
Placas - GEB (139.78 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría