Iniciar sesión:
Votos - 3, Puntuación media: 4.7 ( )

Manual de usuario Wolf, modelo PL402212

Fabricar: Wolf
Tamaño del archivo: 197.86 kb
Nombre del archivo: b5845e0d-f84f-23e4-c99d-56f53c75835a.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The height of the liner does not have to be the same as the height of the decorative hood and is generally shorter. The top depth of the liner, which is 12" (305) standard, must be less than the interior depth of the decorative hood. Measure the interior depth of the hood at the top height of the liner to make sure the liner will fit inside the decorative hood. The hood liner comes standard with a 4" (102) lower reveal. Be sure to include this dimension in your decorative hood selection. Always use the interior measurements of the decorative hood and measure in multiple places. Use the smallest dimensions to verify hood liner specifications. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Planning Information Pro Ventilation Hood Liner MODEL PL402212 DUCTING CONSIDERATIONS Wolf Pro hood liners are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available. IMPORTANT NOTE: Install this ventilation hood liner only with a Wolf blower. Pro hood liners have a vertical discharge location with 10" (254) round duct. A transition with backdraft damper is included. The hood liner will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Wolf Pro hood liners must be vented to the outside. Use only metal ductwork. Refer to the illustration below for ducting considerations for Pro ventilation hood liners. Ducting for Pro ventilation hood liners. 12" (305) HEIGHT OF LINER HOOD LINER DUCTWORK INSTALLATION THROUGH ROOF 10" ROUND DUCT SOFFIT OR CABINET OR DUCT COVER VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS. VERTICAL DISCHARGE 221/2" (572) DEPTH OF LINER DECORATIVE HOOD 30" TO 36" (762–914) COUNTERTOP TO BOTTOM OF DECORATIVE HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT TRANSITION 221/4"W x 9"D TO 10" ROUND 10"H DIMENSIONS INCLUDE FLANGES ROOF CAP OR REMOTE BLOWER Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Planning Information Pro Ventilation Hood Liner MODEL PL402212 WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly. Wolf ventilation hood liners are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer. IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products. Internal blowers are mounted inside the hood liner canopy. In-line blowers are mounted in between the hood liner and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers. Pro ventilation recommendation charts on the following page provide minimum CFM recommendations according to the cooking appliance and hood liner used and blower options for each specific Pro hood liner. 18" (457) 22" 247/8" (632) 12" (305) 18" 8" (203) (559) (457) In-line BLOWER-110IL 241/2" (622) 151/2" (394) 281/4" (718) 203/4" (527) 243/4" (629) 14" (356) 43/4" (121) 10" (254) Diameter 143/4" (375) 291/2" (749) 291/2" (749) 18" (457) 22" (559) 101/8" (257) 71/4" (184) 10" (254) 10" (254) Diameter 143/4" (375) 291/2" (749) 291/2" (749) 21" (533) 25" (635) 103/8" (264) 71/4" (184) 10" (254) 10" (254) Diameter Remote BLOWER-90REM Remote BLOWER-120REM Remote BLOWER-150REM Unit dimensions may vary by ± 1/8" (3). Dimensions in parentheses are in millimeters unless otherwise specified. 7 Planning Information Planning Information Pro Ventilation Hood Liner MODEL PL402212 PRO VENTILATION CFM RECOMMENDATIONS Pro Hood Liners Model PL342212 PL402212 PL462212 PL522212 PL582212 DF304 / R304 / SRT304 600 600 DF366 / R366 / SRT366 / RT366 900 900 DF364 / R364 / SRT364 / RT364 900 900 RT362 900 900 R488 / RT488 1100 1100 DF486 / R486 / SRT486 / RT486 1100 1100 DF484 / R484 / SRT484 / RT484 900 900 DF606 / R606 1500 DF604 1500 MinimumCFMrequirementsfor Wolfrangesandrangetops.CFMrecommendationsare based ontotal Btu/hr output. Additional CFMmayberequiredforcharbroilers,griddles and long duct runs. PRO VENTILATION BLOWER OPTIONS Pro Hood Liners Blower Description Blower Number Hood Liner Models 1200 CFM Internal LBLOWER-120INT (805087) All Hood Liners 1100 CFM In-Line BLOWER-110IL (808332) All Hood Liners 900 CFM Remote BLOWER-90REM (801641) All Hood Liners 1200 CFM Remote BLOWER-120REM (801642) All Hood Liners 1500 CFM Remote BLOWER-150REM (804701) All Hood Liners Dimensions in parentheses are in millimeters unless othe...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría