|
Resumen del manual
2 Planning Information Planning Information Pro 27"(686) Deep Wall Ventilation Hood MODEL PW302718(R) BLOWER OPTIONS SPECIFICATIONS 600 CFM Internal Blower 810559 Overall Width of Hood 30" (762) 900 CFM Internal Blower 811131 Overall Height of Hood 18" (457) 600 CFM In-Line Blower 808331 Overall Depth of Hood 27" (686) 1100 CFM In-Line Blower 808332 (including rail) 29" (737) 600 CFM Remote Blower 801640 Internal Blower Options 600 or 900 CFM 900 CFM Remote Blower 801641 In-Line Blower Options 600 or 1100 CFM 1200 CFM Remote Blower 801642 Remote Blower Options 600, 900, 1200 or 1500 CFM 1500 CFM Remote Blower 804701 Discharge Vertical or Horizontal* Refer to Pro Ventilation Recommendations Duct Size 10" (254) Round at the end of this section. Electrical Supply Requirements 110/120 V AC, 60 Hz 15 amp dedicated circuit ACCESSORIES Shipping Weight (shell only) 92 lbs (42 kg) Platinum or brass decorative rail *Horizontaldischargeapplicationsrequireahorizontaldischargekit. and stand-offs Specifications are subject to change without notice. 38" (965) high classic stainless steel backsplash with or without warming racks 6" (152), 12" (305), 18" (457) and 24" (610) classic stainless steel duct covers Horizontal discharge kit Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator sectionofourwebsite,wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Planning Information Pro 27"(686) Deep Wall Ventilation Hood MODEL PW302718(R) INSTALLATION SPECIFICATIONS 30" TO 36" (762–914) TO COUNTERTOP 30" TO 36" (762–914) TO COUNTERTOP 18" (457) HEIGHT OF HOOD 27" (686) DEPTH OF HOOD NOTE: 27" (686) deep wall hoods are vertical discharge only. DIMENSIONS Overall Width of Hood 30" (762) Overall Height of Hood 18" (457) Overall Depth of Hood (excluding rail) 27" (686) Countertop to Bottom of Hood 30" (762) to 36" (914) Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Planning Information Pro 27" (686) Deep Wall Ventilation Hood MODEL PW302718(R) INSTALLATION NOTES Refer to the illustrations and specifications for overall dimensions and installation specifics. Wolf Pro wall ventilation hoods are recommended for use with any Wolf cooking appliance, and should be as least as wide as the cooking surface. It is recommended that the hood overlap the cooking surface by 3" (76) on either side. IMPORTANT NOTE: For optimal performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle. Installation of all Pro ventilation hoods should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration on page 4. Wolf Pro wall hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for Pro ventilation recommendations and blower options. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro wall hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Locate electrical within the shaded area shown in the Installation illustration on page 4. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Planning Information Pro 27" (686) Deep Wall Ventilation Hood MODEL PW302718(R) DUCTING CONSIDERATIONS Wolf Pro 27" (686) deep wall hoods are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro 27" (686) deep wall hoods have a vertical discharge. A horizontal discharge kit is available as a sales accessory. The hood will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Wolf Pro 27" (686) deep wall hoods must be vented to the outside. Use only metal ductwork. Refer to the illustration below for ducting considerations for Pro 27" (686) deep wall hoods. Ducting for Pro 27" (686...
Otros modelos de este manual:Los aficionados - PW302718(R) (221.61 kb)