|
Resumen del manual
Then, slide in the diffuser (2). See illustration beside. VD0158 - 12 6.1 MAIN SWITCH All units are equipped with a 3-position main switch, located on the front panel. 6.2 40415 AND 40425 WALL CONTROLS DESCRIPTION The included wall control is 40415 (intented for HRV 2600, HEPA 3100 and HEPA 4100 units only) or 40425 control (intented for HR 2.6 and HF 3.1 units only). The wall control is in OFF mode when power is applied for the first time. The mode does not change following a power failure. 40415 CONTROL OR 40425 CONTROL 6.3 OPERATING 40415 / 40425 CONTROLS The wall controls 40415 and 40425 provide 5 operation modes. Press the Mode button to select the desired mode. 6. CONTROLS OFF: UNIT IS OFF AND DOOR IS UNLOCKED. NORMAL/REMOTE: UNIT IS OPERATING ON NORMAL SPEED. THIS IS THE RIGHT POSITION WHEN A WALL CONTROL IS USED. BOOST: UNIT IS OPERATING ON HIGH SPEED. VC0098 VC0053 - 18 - ILLUMINATES IN ALL MODES EXCEPT OFF MODE. FILTER AND PREFILTER MAINTENANCE LED. FLASHES WHEN IT IS TIME TO REPLACE PREFILTER AND WASH CORE FILTERS. SEE BIANNUAL MAINTENANCE IN SECTION 7.1. LIGHTS UP WHEN IT IS TIME TO REPLACE FILTER AND PREFILTER AND WASH CORE FILTERS. SEE ANNUAL MAINTENANCE SECTION 7.2. The unit exchanges air at normal speed. The outdoor temperature* is displayed. The unit exchanges air at high speed. The outdoor temperature* is displayed. The unit recirculates air. However, every 20 minutes the unit exchanges air for 2.5 minutes so that it can obtain a reading of the outdoor temperature*. The unit operates on a 60-minute cycle. For the first 40 minutes, the unit recirculates air or is off (See configuration parameter 2). For the last 20 minutes, it exchanges air. However, if the outdoor temperature* is too high or too low (see configuration parameters 3 and 4), the unit recirculates air during the last 20 minutes. NORMAL MODE (MIN) BOOST MODE (MAX) RECIRCULATION MODE (RE-CIRC) OFF MODE The unit is off. The outdoor temperature* is not displayed. Off in Auto mode Air exchange in Auto mode Air recirculation in Auto mode AUTOMATIC MODE (AUTO) PRESS THIS BUTTON TO ACCESS CONFIGURATION PARAMETERS (SEE SECTION 6.4). • PRESS EITHER BUTTON TO CHANGE CONFIGURATION SETTING (SEE SECTION 6.4). • PRESS BOTH BUTTONS TO RESET THE FILTER COUNTER OR PREFILTER COUNTER. PRESS THIS BUTTON TO SWITCH MODE (SEE SECTION 6.3). * The outdoor temperature reading is taken from the unit FRESH AIR FROM OUTSIDE port; due to the lenght of the insulated duct, the reading is slightly different from the real outside temperature. 6. CONTROLS (CONT’D) 6.4 WALL CONTROLS CONFIGURATION See the configuration table below for the list of configuration parameters. Press the Menu button for 3 seconds to enter or exit the configuration menu. NOTE: The wall control automatically saves any changes and exits the configuration menu if no button is pressed within the next 60 seconds. Press the Menu button briefly to advance to the next parameter (menu number). Press the or button to change the parameter setting. CONFIGURATION TABLE MENU NUMBER PARAMETER OPTIONS DEFAULT SETTING DESCRIPTION 1 TEMPERATURE FORMAT °C / °F °C SELECTS BETWEEN °C AND °F DISPLAY. 2 AUTO MODE OPERATION RE / OF RE SELECTS BETWEEN AIR RECIRCULATION (RE) AND OFF (OF) (SEE SECTION 6.3). 3 AUTO MODE LOW TEMPERATURE LIMIT -30°C TO 0°C (-22°F TO 32°F) -25°C (-13°F) PREVENTS AIR EXCHANGE IN AUTO MODE IF THE OUTDOOR TEMPERATURE IS TOO LOW (SEE SECTION 6.3). 4 AUTO MODE HIGH TEMPERATURE LIMIT 0°C TO 30°C (32°F TO 86°F) 27°C (81°F) PREVENTS AIR EXCHANGE IN AUTO MODE IF THE OUTDOOR TEMPERATURE IS TOO HIGH (SEE SECTION 6.3). 5 BACKLIGHT MODE AU / ON AU AU: THE SCREEN ILLUMINATES FOR 12 SECONDS WHEN ANY KEY IS PRESSED ON: THE SCREEN IS PERMANENTLY ILLUMINATED. - 19 7. MAINTENANCE WARNING Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source. ! 7.1 BIANNUAL MAINTENANCE (ESSENTIAL) Perform this maintenance when the Filter Maintenance LED is flashing. Follow these steps: 1. Turn switch knob to OFF to unlock the door. 2. Unlatch the door and open it. Clean the inner side of the door with a clean damp cloth, them wipe with a dry one. 3. Slide out the heat recovery core (HRV 2600, HR 2.6, HEPA 3100 and HF 3.1 units only) or the energy recovery core (HEPA 4100 unit only) and the filter cartridge from the unit. NOTE: To remove the filter cartridge, pull on its tabs (item 3). 1 VD0091 VD0112 3 2 VD0155 1) Heat Recovery Core 2) Energy recovery Core 3) Filter Cartridge Tabs 4. Using your thumbs, push on the prefilter side to disengage it from the filter cartridge. Then, slide it out of the filter cartridge and discard it. Install the new prefilter by reversing this operation. 1 2 VD0092 VD0093 1) Filter cartridge 2) Prefilter NOTE: HRV 2600 and HR 2.6 units do not have prefilter. To clean the washable foam filter (MERV 8), vacuum to remove most of the dust. Let it soak in a solution of warm water and mild soap. Rinse thoroughly and let dry befor...
Otros modelos de este manual:Los aficionados - HEPA 3100* (4.18 mb)
Los aficionados - HEPA 4100* (4.18 mb)