Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Miele, modelo DA 219-2

Fabricar: Miele
Tamaño del archivo: 914.86 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


See "Warning and Safety instructions" for further information. A distance of 650 mm may be preferable above electric hobs / cookers to give more working space. Appliance height H: DA 216-2 Extraction and EXT . . . . . 700* -940 mm Recirculation . . . . . . . . . 790 -1025 mm DA 217-2 Extraction . . . . . . . . . . . . 710* -950 mm Recirculation . . . . . . . . . 800 -1035 mm DA 219-2 Extraction and EXT . . . . . 730* -970 mm Recirculation. . . . . . . . . 820 - 1055 mm * With air extraction to the rear through a wall the total height must be at least 790 mm. To fit the tower, distance A between the top of the tower and the ceiling When deciding dimension S ensure that the minimum specified safety distance between the hob / cooker and the cooker hood is maintained. If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than appliance height H. must be at least 20 mm. The shaded area represents the wall or ceiling area for the vent cutout, for feeding the connection cable through to an external fan and for fitting the connection socket. (For recirculation mode the connection socket may only be fitted in a wall area). Connection for air extraction o 150 mm or o 125 mm with reducing collar. Installation Assembly parts Installation 22 Installation b 2 recirculation grilles (for recirculation mode only) c 2 protective sheets for use when fitting the tower. d 1 protective sheet for use when fitting the tower. e 1 directional unit (for recirculation mode only) f 1 flexible aluminium hose for connecting the directional unit to the exhaust socket on the motor unit (not on EXT models). g 2 hose clips for securing the exhaust ducting. h 1 reducing collar for exhaust ducting o 125 mm (not on EXT models). i 1 non-return valve for fitting into the exhaust socket on the motor unit (for extraction mode only, not on EXT models). j 1 exhaust connection for fitting in the canopy (only with EXT models). k Upper retaining plate B for securing the extension piece. l Middle retaining plate C for additional stability of the tower. m Lower retaining plate A for securing the canopy and the motor unit. 12 large headed screws 5 x 40 mm and 12, S 8 plugs for securing the retaining plates and the canopy. 2 M 6 locking nuts for securing the motor unit/control unit. 4 screws 3.9 x 7.5 mm for securing the tower and the extension piece. 4 screws 4.2 x 13 mm for securing the exhaust socket in the canopy (only with EXT models). Installation Retaining plates There are three retaining plates A, B and C for fixing the cooker hood to the wall. First of all drill the holes for attaching the canopy and for fitting retaining plate A. Before fitting the retaining plate draw a vertical line centrally above the hob on the back wall. Mark measurement S from the hob surface upwards (see "Appliance dimensions"). This marks the height of the lower rim of the cooker hood. DA 216-2 / EXT, 217-2: Drill an 8 mm o hole on the middle line 18 mm above the height marked S. Insert an S8 plug into the hole. DA 219-2 / EXT: Drill two 8 mm o holes, 18 mm above the height marked S and 250 mm right and left of centre. Insert S8 plugs. Retaining plate A Drill two 8 mm o holes, one at S + 100 mm and one at S + 425 mm on the centre line for the retaining plate (see "Appliance dimensions"). Insert S8 plugs. Installation Lightly secure retaining plate A into position using 5 x 40 mm screws through the two holes and use the notches to align with the middle line. Drill 4 more 8 mm o holes through the now fitted retaining plate and press S8 plugs into the holes. Screw two 5 x 40 mm screws into the upper two holes. Retaining plate B Hold retaining plate B to the wall and push up until it is directly below the ceiling. Use the notches and the middle line to align it horizontally. Mark the 2 drill holes on the wall. Drill two, 8 mm o holes into the wall, and push the S8 plugs into the holes. Screw on the retaining plate with two 5 x 40 mm screws. Retaining plate C Retaining plate C only needs to be fitted if dimension Y is greater than 365 mm. It provides additional stability for the extension piece. Installation At a maximum distance of 365 mm from the ceiling, hold retaining plate C against the wall and use the notches to align it with the middle line. Mark the two drill holes. Drill two 8 mm o holes into the wall and press the S8 plugs into the holes. Screw on retaining plate C with two 5 x 40 mm screws. Canopy Before fitting the canopy the glass cover of the lighting tube must first be removed (see relevant section in "Cleaning and care"). Hang the canopy on the angle brackets on retaining plate A. Secure the canopy. Secure the canopy with 5 x 40 mm screws into each drilled hole. DA 216-2 / EXT, 217-2: Secure the canopy with a 5 x 40 mm screw. DA 219-2 / EXT: Secure the canopy with two 5 x 40 mm screws. Replace the glass cover. Motor unit (not when operating the external fan) with air extraction If a non-return fla...

Otros modelos de este manual:
Los aficionados - DA 216-2 (914.86 kb)
Los aficionados - DA 216-2 EXT (914.86 kb)
Los aficionados - DA 217-2 (914.86 kb)
Los aficionados - DA 219-2 EXT (914.86 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría