|
Resumen del manual
Burner will not come on. Control knob frozen – will not turn. Carbon or sooting on logs. POSSIBLE CAUSE Altitude is above 4000 ft.; ODS sensor requirement for air not satisfied.> Defective thermopile.> Pilot orifice may be clogged.> Defective valve magnet.> Control knob not fully pressed in.> Control knob not pressed in long enough.> Manual shut-off valve not fully open.> Low gas pressure.> Dirty or clogged “ODS” pilot.> Thermopile damaged.> Control valve damaged.> Burner orifice clogged.> Orifice is too small.> Inlet gas pressure too low.> Problem with gas pressure.> Control not on or is set on “LOW”. Gas valve may be clogged due to debris entering valve during installation.> Faulty gas valve.> Burner ports and/or carryover ports may be clogged.> Manifold pressure is too low.> Burner or orifice is clogged.> Orifice clogged or damaged.> Burner damaged.> Dirt on valve seal.> Defective valve; foreign material.> Logs out of position.> Air holes on burner tube obstructed.> Gas type does not match stove.> Oversized orifice.> LP fuel may have additives.> Gas pressure may be incorrect.> SOLUTION Altitude is too high. *Replace thermopile. *Clean out pilot orifice. *Replace valve. Press in knob completely. Hold 30 sec. after pilot lights. Fully open shut-off valve. *Contact gas supplier. *Replace assembly or service. *Replace thermopile. *Replace control valve. *Clean burner; replace orifice. *Replace orifice if necessary. *Contact gas supplier. *Check gas pressure. Move to “HIGH” setting. *Replace gas valve. *Replace gas valve. *Check and clean ports. *Contact gas supplier. *Check and clean both. *Clean and/or replace. *Clean and/or replace. *Replace valve. *Replace valve. See log placement in manual. *Clean if necessary. Check designation on valve. *Change if necessary. *Check with gas supplier. *Check with gas supplier. WARRANTY INFORMATION ¦KEEP THIS WARRANTY¦ Model #__________________________________ Serial #__________________________________ Date Purchased ___________________________ Manufacture Date _________________________ Purchased From (Dealer) ____________________ NOTE: Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY This unvented gas heater firebox is warranted for a period of five (5) years; the logs, valve, burner and all other components for a period of one (1) year from the date of purchase against defects in material or workmanship. This warranty covers only the cost of defective parts and applies only to the original consumer purchaser. The replacement of defective parts will be without charge. This warranty does not extend to: 1. Heater damage by accident, neglect, misuse, abuse, alteration, negligence of others, improper installation, including the installation thereof by unqualified installers. 2. ...
Otros modelos de este manual:Los aficionados - 60-TRULP (136.53 kb)
Los aficionados - 26-GUHLP (136.53 kb)
Los aficionados - 26-GUHNG (136.53 kb)
Los aficionados - 26-GULP (136.53 kb)