Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario CFM, modelo M-0710

Fabricar: CFM
Tamaño del archivo: 36.34 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Cut square wall opening size .” larger than fan blade diameter. 2. From inside of building / room, center fan assembly over wall opening. Fan must be positioned so that junction box is located at bottom and shutter is level and square, with shutter blades opening upwards. 3. Lag fan to wall through mounting holes in shutter gusset, using appropriate fasteners (by others). 4. Rotate fan impeller by hand, ensuring that it is unobstructed and rotates freely. 5. Make electrical connections to fan junction box. When shutter and fan assembly are mounted separately: 1. Cut wall opening size .” larger than fan blade diameter. 2. From inside of building / room, center fan assembly over wall opening. Fan must be positioned so that junction box is located at bottom. 3. Lag fan to wall through wire hooks on guard, using the appropriate fasteners (by others). 4. Apply caulking compound (by others) to rear of shutter gusset. 5. From outside of building / room, center shutter over wall opening, ensuring that shutter is level and square, with shutter blades opening upwards. 6. Lag shutter to wall through mounting holes in shutter gusset, using appropriate fasteners (by others). 7. Rotate fan impeller by hand, ensuring that it is unobstructed and rotates freely. 8. Make electrical connections to fan junction box. M MMO OOD DDE EEL LL P PPE EEF FF- --1 110 00 T TTH HHR RRO OOU UUG GGH HH P PPE EEF FF- --3 330 00 1. Cut wall opening size .” larger than fan venturi opening. 2. From inside of building / room, center fan panel assembly over wall opening. Fan must be positioned so that junction box is located at bottom. 3. Lag fan to wall through mounting holes in panel, using appropriate fasteners (by others). 4. Rotate fan impeller by hand, ensuring that it is unobstructed and rotates freely. 5. Make electrical connections to fan junction box. M MMO OOD DDE EEL LLS SS G GGE EEF FF- --1 110 00 T TTH HHR RRO OOU UUG GGH HH G GGE EEF FF- --3 330 00 1. Cut wall opening size .” larger than fan blade diameter. 2. From inside of building / room, center fan assembly over wall opening. Fan must be positioned so that junction box is located at bottom. 3. Lag fan to wall through wire hooks on fan guard, using the appropriate fasteners (by others). 4. Rotate fan impeller by hand, ensuring that it is unobstructed and rotates freely. 5. Make electrical connections to fan junction box. R RRE EEC CCO OOM MMM MME EEN NND DDE EED DD M MMA AAI IIN NNT TTE EEN NNA AAN NNC CCE EE 1. When undertaking maintenance or service work, ensure that electrical service to fan is locked in the “OFF” position to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a tag to service panel. 2. Do not re-establish power supply until maintenance or service work has been completed. 3. Maintenance or service work must be performed by a qualified person in accordance with all applicable codes and standards...

Otros modelos de este manual:
Los aficionados - GEF10 (36.34 kb)
Los aficionados - GEF30 (36.34 kb)
Los aficionados - PEF10 (36.34 kb)
Los aficionados - PEF30 (36.34 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría