Iniciar sesión:
Votos - 5, Puntuación media: 3.8 ( )

Manual de usuario Xpelair, modelo Pro Wall

Fabricar: Xpelair
Tamaño del archivo: 485.06 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


FILTER GREASE CUP SIDE VIEW Filterinstallation. ELECTRICAL BOX Location of electrical box. Pro Wall Hood Installation Wolf Nameplate The Wolf logo nameplate does not come installed on the hood since there are various locations that the nameplate can be attached. Once you've decided on the location for the nameplate, clean the mounting area with rubbing alcohol. Remove the backing paper from the nameplate. Position the nameplate aligned parallel with the bottom edge of the hood and press into place. Blower Assemblies Pro ventilation hoods are shipped without the blower assembly. Internal, in-line and remote blowers are avail- able through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. Refer to ventilation recommenda- tions in the Wolf design guide. IMPORTANT NOTE: Use only a Wolf blower with the pro ventilation hood. IMPORTANT NOTE: Refer to specific installation instruc- tions provided with each blower assembly for additional mounting and wiring instructions. Pro Wall Hood Installation wolfappliance.com/specs Internal Blowers IMPORTANT NOTE: For low-profile wall hoods using the 500 CFM internal blower, refer to installation instructions provided with the blower assembly. Install the internal blower prior to mounting the hood. IMPORTANT NOTE: For 24" (610) and 27" (686) deep wall hoods using an internal blower, refer to installation instructions provided with the blower assembly. Install the internal blower to the hood back plate assembly prior to mounting the hood. IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL. BLOWERHOUSINGHOODBACKPLATEBLOWERMOUNTINGPLATEInternalblowerassembly. BLOWER INSTALLATION—24" AND 27" WALL HOODS • Assemble the blower housing to the blower mounting plate. Follow installation instructions included with the blower assembly for proper installation. • Attach the blower assembly to the hood back plate. To attach, slide the blower mounting plate over the weld studs and secure with eight nuts (provided with the blower). Refer to the illustration. • Verify that the blower discharge aligns with the discharge cut-out in the hood back plate. • Install the hood and blower assembly to the wall. Secure the power cord(s) without damaging or pinching while installing the hood. • Follow hood installation instructions on pages 12–13 for low-profile wall hoods, and pages 14–16 for 24" (610) and 27" (686) deep wall hoods. • Once the hood installation is complete, plug the blower power cord(s) into receptacle(s) located near the center of the hood shell. Refer to the illustration below. Use the clips on the interior of the hood to secure excess power cord. IMPORTANT NOTE: Before turning the power on to the ventilation hood, make sure the blower is off. BLOWERRECEPTACLE(S) Locationofreceptacle(s). Pro Wall Hood Installation In-Line and Remote Blowers Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. The duct run should be no longer than 50' (15 m). If possible, remote blowers should be located between wall studs or roof rafters. Avoid pipes, wires and other ductwork. Be sure there is enough space for transitions needed between the blower and connecting ductwork. For best performance, locate transitions nearest the blower. IN-LINE AND REMOTE BLOWER DIMENSIONS 113/4" (298) 211/2" (546) 243/8" (619) 181/2" (470) 121/4" (311) 41/2" (114) 18" (457) Refer to the illustrations below for overall dimensions of Wolf in-line and remote blowers. Installation instructions shipped with each Wolf ventilation product provide detailed specifications. These instructions can also be found on our website, wolfappliance.com/specs. 22" (559) 247/8" (632) 12" (305) 18" (457) 8" (203) 600 CFM in-line blower. 1100 CFM in-line blower. 241/2" (622) 151/2" (394) 281/4" (718) 203/4" (527) 243/4" (629) 14" (356) 43/4" (121) 10" (254) Diameter 143/4" (375) 291/2" (749) 291/2" (749) 18" (457) 22" (559) 101/8" (257) 71/4" (184) 10" (254) 10" (254) Diameter 143/4" (375) 291/2" (749) 291/2" (749) 21" (533) 25" (635) 103/8" (264) 71/4" (184) 10" (254) 10" (254) Diameter 600 CFM and 900 CFM remote blower. 1200 CFM remote blower. 1500 CFM remote blower. Pro Wall Hood Installation wolfappliance.com/specs In-Line and Remote Blowers BLOWER INSTALLATION IMPORTANT NOTE: Refer to specific installation instruc- tions provided with each blower assembly for additional mounting and wiring instructions. IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL. • Follow specific wiring instructions provided with each blower. Black (L1) to black, white (neutral) to white, or white to blue, or white to brown (depending on model) and green to grounding screw. Run ROMEX cable to the hood. • Insert 6" (152) of ROMEX cable through the kno...

Otros modelos de este manual:
Los aficionados - 811504 (485.06 kb)
Los aficionados - 811504 (485.06 kb)
Los aficionados - Pro Wall (485.06 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría