Iniciar sesión:
Votos - 4, Puntuación media: 3.3 ( )

Manual de usuario Xpelair, modelo L342212

Fabricar: Xpelair
Tamaño del archivo: 193.97 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Make sure all wires are secure and that no wires are pinched between the cover and electrical box. 17/8" (48) 31/2" (89) 121/2" (318) Location of hood wiring. Pro Hood Liner Installation Blower Assemblies Pro ventilation hoods are shipped without the blower assembly. Internal, in-line and remote blowers are avail- able through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. Refer to ventilation recommenda- tions in the Wolf design guide. IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL. To reduce the risk of fire and electric shock, install this ventilation hood liner only with a blower manufactured by Wolf. wolfappliance.com/specs Internal Blower BLOWER INSTALLATION IMPORTANT NOTE: Refer to specific installation instruc- tions provided with each blower assembly for additional mounting and wiring instructions. 1) Engage the blower mounting tab into the hood liner top plate mounting slot. Make sure the blower tab and mounting slot are aligned properly front to back. 2) Secure the blower with the weld stud at the front of the blower and hood liner top plate and the nut (included with blower). Verify that the blower discharge aligns with the top plate discharge cut-out of the hood liner. 3) Once the hood liner installation is complete, plug the blower power cord(s) into receptacle(s) located near the center of the hood liner shell. Use the clips on the interior of the hood liner to secure excess power cord. IMPORTANT NOTE: Before turning electrical power on to the ventilation hood liner, make sure the blower is off. MOUNTING SLOT TOP / BACK PLATE WELD STUD BLOWER HOUSING NUT MOUNTING TAB Internal blower assembly. Pro Hood Liner Installation In-Line and Remote Blowers BLOWER INSTALLATION IMPORTANT NOTE: Refer to specific installation instruc- tions provided with each blower assembly for additional mounting and wiring instructions. Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. The duct run should be no longer than 50' (15 m). Remote blowers should be located between wall studs or roof rafters. Avoid pipes, wires and other ductwork. IN-LINE AND REMOTE BLOWER DIMENSIONS 18" (457) 22" (559) 247/8" (632) 12" (305) 18" (457) 8" (203) 1100 CFM in-line blower. Allow enough space for transitions needed between the blower and connecting ductwork. For best performance, locate transitions nearest the blower. Refer to the illustrations below for overall dimensions of Wolf in-line and remote blowers. Installation instructions shipped with each Wolf ventilation product provide detailed specifications. These instructions can also be found on our website, wolfappliance.com/specs. 241/2" (622) 151/2" (394) 281/4" (718) 203/4" (527) 243/4" (629) 14" (356) 43/4" (...

Otros modelos de este manual:
Los aficionados - L342212 (193.97 kb)
Los aficionados - L582212 (193.97 kb)
Los aficionados - L402212 (193.97 kb)
Los aficionados - L462212 (193.97 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría