Iniciar sesión:
Votos - 5, Puntuación media: 4.2 ( )

Manual de usuario Electrolux, modelo 8609 D

Fabricar: Electrolux
Tamaño del archivo: 574.54 kb
Nombre del archivo: 219500EN.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


7, Part 1). Connection 220 V~ via fixed supply lead with protective contact plug (Eu-ropa version). 240 V~ via fixed supply lead (UK). (Fixed connection to be made only by an approved electrical installer) This appliance complies with the radio interference suppression requirements of EC Directives 76/889 EC and 82/499 EC. The exhaust air may not be introduced into a smoke flue or exhaust gas chimney. Introduction of the exhaust air into a shaft used for ventilation of the installation spaces of firerooms is not permitted. If the exhaust air is introduced into a non-operational smoke flue or exhaust gas chimney, it is advisable to seek the consent of the competent chimney-sweep. The official exhaust air guidance regulations are basically to be complied with. During operation as an exhaust air appliance, an adequate supply air opening of approximately the same size as the exhaust air opening is to be ensured. According to the Provincial Building Regulations, the joint operation of fume extractor hoods and chimney-linked fireplaces, such as coal- or oil-fired ovens and gas heaters, in the same space is subject to specific restrictions. In such spaces, the Fireplace Regulations only allow an underpressure of max. 0.04 mbar. The safe joint operation of chimney-linked appliances and fume extractor hoods is only guaranteed if space and/or dwelling (space/air interaction) are externally ventilated by a suitable supply air opening of around 500—600 cm2 and an underpressure thereby avoided when the fume extractor hood is running. SIE2 5/90 - SIKM1 11/89 GB/EU SIKM1 11/89 - SIKM3 5/90 GB/EU In doubtful cases, please seek the advice and consent of the competent area chimney-sweep or the local building authorities. Since, in spaces without fireplace, the rule is: “Supply air opening as large as exhaust air opening”, the efficiency of the exhaust air device may be impaired by the greater opening of 500-600 cm2. Operation of the hood as a return air hood in such circumstances is safe and is not subject to the regulations noted above. Operation of the fume extractor hood in return air mode is optimum only when the following are ensured: — short, straight exhaust air runs — as few pipe bends as possible — running of pipes in flat arcs, not in acute angles — as large as possible pipe diameters (basically min. 120 mm dia. for two-motor hoods). Failure to observe these principles is inevitably associated with power losses and increased operating noise. During installation of the fume extractor hood, the following minimum distances from the upper edge of the hob to the lower edge of the fume extractor hood must be complied with: Electric cookers 650 mm Gas cookers 650 mm Coal- and oil-fired cookers min. 700 mm For the kitchen furniture installer General Appliance description The fume extractor hood is supplied as an exhaust air appliance and may be used as a return air appliance through application of an active carbon filtre (speci...

Otros modelos de este manual:
Los aficionados - 860 D (574.54 kb)
Los aficionados - 860 D (574.54 kb)
Los aficionados - 8609 D (574.54 kb)
Los aficionados - 8609 D (574.54 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría