Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Sony, modelo SLV-SX600E

Fabricar: Sony
Tamaño del archivo: 1.13 mb
Nombre del archivo:
Idioma del manual:entr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


In this case, manually adjust the tracking. During playback, press TRACKING +/– to display the tracking meter. The distortion should disappear as you press one of the two buttons (the indicator TRACKING Tracking meter lights up). To resume automatic tracking adjustments, eject the tape and re-insert it. About the Reality Regenerator (RR) function (not available on SLV-SE600A/E and SX600E) The Reality Regenerator (RR) function automatically restores the picture to its original quality during playback. To use the RR function, press RR. The RR button lights up. You can set RR to NORMAL or HIGH in the OPTIONS-2 menu (see page 79). To turn it off, press RR. The RR RR button turns off. About the Optimum Picture Control (OPC) function The Optimum Picture Control (OPC) function automatically improves recording and playback quality by adjusting the VCR to the condition of the video heads and tape. To maintain better picture quality, we recommend that you set OPC to ON in SELECT : OPTIONS - 1 ON OFF OFF OPC OFF NICAMHIFI AUDIO E180 EDIT AUDIO MIX AUTO LONG PLAY TAPE LENGTH RETURN the OPTIONS-1 menu (the OPC indicator lights up in the display window). For details, see page 78. SET : EXIT : MENU OK OPC playback The OPC function automatically works on all types of tapes, including rental tapes and tapes that were not recorded with OPC. OPC recording Whenever you insert a tape and start recording for the first time, the VCR adjusts to the tape using the OPC function (the OPC indicator flashes rapidly). This adjustment is retained until the tape is ejected. Adjusting the picture To deactivate the OPC function Set OPC to OFF in the OPTIONS-1 menu. The OPC indicator in the display window turns off. Tip • To set tracking to the centre position, press the TRACKING + and – buttons at the same time. Notes • You can adjust the tracking for an NTSC-recorded tape but the tracking meter won’t be displayed. • With the Auto Long Play function on, the OPC function will work only in SP mode. If the tape speed automatically switches from SP to LP, the OPC function turns off. If, however, the entire programme is recorded in LP mode, the OPC function will work. • There is a delay of about ten seconds before the VCR actually starts recording while the VCR analyses the tape. To avoid the delay, first set the VCR to recording pause (the OPC indicator flashes slowly) and press z REC to have the VCR analyse the tape (the OPC indicator flashes rapidly) and return to recording pause. After the OPC indicator stops flashing, press X PAUSE to start recording immediately. If you want to start recording quickly without using the OPC function, first set the VCR to recording pause (the OPC indicator flashes slowly) and press X PAUSE again to start recording. Additional Operations Adjusting the picture Changing menu options 1 Press MENU, then select OPTIONS and press OK. RETURN SET : SELECT : OK MENUEXIT : OPTIONS OPTIONS - 1 OPTIONS - 2 2 Press M/m to highlight OPTIONS-1 or OPTIONS-2, then press OK. SELECT : OPTIONS - 1 OFF OFF NICAM ON OFF E180 OPC EDIT AUDIO MIX HIFI AUDIO AUTO LONG PLAY TAPE LENGTH RETURN SELECT : OPTIONS - 2 TIMER OPTIONS DECODER / LINE3 POWER SAVE TV DIRECT REC VARIABLE DECODER OFF ON RR NORMAL RETURN SET : OK SET : MENU OK EXIT : EXIT : 3 Press M/m to select the option, then press OK. 4 Press M/m to change the setting, then press OK. 5 Press MENU to return to the original screen. Menu choices Initial settings are indicated in bold print. OPTIONS-1 MENU Menu option Set this option to OPC • ON to switch on the OPC (Optimum Picture Control) function and improve picture quality. • OFF to switch off OPC. EDIT • ON to minimize picture deterioration when editing. • OFF to turn off EDIT. AUDIO MIX • ON to listen to the hi-fi and normal audio tracks at the same time. The AUDIO MONITOR button will not function. • OFF to listen to the hi-fi and normal audio tracks separately. Select the sound using the AUDIO MONITOR button. If you press Z EJECT, AUDIO MIX will be reset to OFF. For details, see page 71. HIFI AUDIO*1 • NICAM to record NICAM broadcasts on the hi-fi audio track. • STANDARD to record standard sound on the hi-fi audio track. For details, see page 70. Changing menu options Menu option Set this option to AUTO LONG PLAY • ON to change the timer recording tape speed automatically to the LP mode when the remaining tape length becomes shorter than the recording time. Note that for AUTO LONG PLAY to work correctly, the TAPE LENGTH setting must be accurate. • OFF to keep the set tape speed. TAPE LENGTH • E180 to use an E-180 or shorter type tape. • E195 to use an E-195 type tape. • E240 to use an E-240 type tape. • E300 to use an E-300 type tape. OPTIONS-2 Menu option Set this option to DECODER/LINE2*2 • DECODER to use the DECODER/LINE-2 IN*2 connector as the PAY-TV/Canal Plus decoder connector. • LINE2 to use the DECODER/LINE-2 IN*2 connector as the line input connector. DECODER/LINE3*3 • DECODER to use the DECODER/LINE-3 IN*3 connector...

Otros modelos de este manual:
VCR / vídeo - SLV-SE600A (1.13 mb)
VCR / vídeo - SLV-SE600E (1.13 mb)
VCR / vídeo - SLV-SE650D (1.13 mb)
VCR / vídeo - SLV-SE700D1 (1.13 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría